Presentation for Qualification

Achievement Probation Period


ZTE Indonesia
Mid Plaza 2 15
th
floor
By
Rudy Kusuma Setiadi
Ass Maintenance Engineer
Main Job During Probation
My first duty in Lampung with Mr. Luo Li
Tao
Try to debug BSC in Lampung

Hardware & Cabling of BSC Installation
BSC Software Installation
Debugging BSC
Contents
Rack 1
Shelf 1 (BUSN)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
DTB DTB IWFB IWFB IWFB IWFB IWFB IWFB UIMU UIMU IWFB VTCD VTCD VTCD SPB SDU SDU
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
RUIM1 RUIM1 RGIM2
Front plug
Rear plug
CABLING OF RACK 1
Shelf 1 (L3 - BUSN)
L3-10 (RUIM1)-FE-
C1/2 from L4-15
(RCHB1)-FE 17-24
L3-9 (RUIM1)-FE-
C1/2 from L4-15
(RCHB1)-FE 17-24
L3-10 (RUIM1)-
CLKIN from L4-13
(RCKG1)-CLKOUT
L3-9 (RUIM1)-
CLKIN from L4-13
(RCKG1)-
CLKOUT
L3-1(RDTB)-
8KOUT/DEBUG-232
from L4-13(RCKG1)-
8KIN1
L3-1 (RDTB)-T1/E1
1-10 from DDF
L3-2 (RDTB)-T1/E1
11-21 from DDF
L3-2 (RDTB)-T1/E1
22-32 from DDF
L3-1 (RDTB)-T1/E1
11-21 from DDF
L3-1 (RDTB)-T1/E1
22-32 from DDF
L3-2 (RDTB)-T1/E1
1-10 from DDF
Rack 1 Shelf 1 (BUSN)
Rack 1
Shelf 2 (BCTC)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
MP MP MP MP MP MP UIMC UIMC OMP OMP CLKG CLKG CHUB CHUB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
RUIM2 RUIM3 RMPB RMPB RCKG1 RCKG2 RCHB1 RCHB2
Front plug
Rear plug
CABLING OF RACK 1
Shelf 2 (L4-BCTC)
L4-15(RCHB1)-FE17-24 from :
1.L3-10(RUIM1)-FE-C1/2
2.L3-9(RUIM1)-FE-C1/2
3.L6-9(RUIM1)-FE-C1/2
4.L6-10(RUIM1)-FE-C1/2
L4-14(RCKG2)-PP2S/16CHIP from L7
GCMCLK0(GCMLK1)
L4-13(RCKG1)-CLKOUT from :
1.L4-10(RUIM3)-CLKIN
2.L4-9(RUIM2)-CLKIN
3.L3-9(RUIM1)-CLKIN
4.L3-10(RUIM1)-CLKIN
5.L6-9(RUIM1)-CLKIN
6.L6-10(RUIM1)-CLKIN



CABLING OF RACK 1
Shelf 2 (L4-BCTC)
L4-14(RCKG2)-CLKOUT from
(Cabinet 2) :
1. L3-10(RUIM1)-CLKIN
2. L3-9(RUIM1)-CLKIN
3. L4-16(RUIM3)-CLKIN
4. L4-15(RUIM2)-CLKIN
L4-12(RMPB)-OMC2 from
switch port 3 (vlan2)
L4-11(RMPB)-OMC2 from
switch port 4 (vlan2)
L4-9(RUIM2)-FE7
from switch port 5
(vlan2)
L4-15(RCHB1)-FE 9-16 from (Cabinet
2):
1.L3-10(RUIM1)-FE-C1/2
2.L3-9(RUIM1)-FE-C1/2
3.L4-16(RUIM3)-FE-2
4.L4-15(RUIM2)-FE-1
CABLING OF RACK 1
Shelf 2 (L4-BCTC)
L4-13(RCKG1)-8KIN1 from L3-
1(RDTB)-8KOUT/DEBUG-232
L4-13(RCKG1)-8KIN2 from L7-
GCM8K
L4-11(RMPB)-GPS485 from L7-GCM
RS485
L4-11(RMPB)-PD485 from L1- RS485
L4-10(RUIM3)-CLKIN from L4-
13(RCKG1)-CLKOUT
L4-9(RUIM2)-CLKIN from L4-
13(RCKG1)-CLKOUT
Rack 1 Shelf 2 (BCTC)

Rack 1
Shelf 3 (L6-BUSN)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
DTB IPCFE IPCFE UPCF UPCF ABPM ABPM UIMU UIMU SDU SDU SDU
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
RDTB RMNIC RMNIC RMNIC RUIM1 RUIM1
Front plug
Rear plug
CABLING OF RACK 1
Shelf 3 (L6-BUSN)
L6-10(RUIM1)-FE-C1/2 from L4-
15(RCHB1)-FE17-24
L6-9(RUIM1)-FE-C1/2 from L4-
15(RCHB1)-FE17-24
L6-10(RUIM1)-CLKIN from L4-
13(RCHB1)-FE17-24
L6-9(RUIM1)-CLKIN from L4-
13(RCHB1)-FE17-24
L6-4(RMNIC)-FE1 from SWITCH
PORT 13 (vlan3)
L6-3(RMNIC)-FE1 from SWITCH
PORT 14 (vlan3)
L6-4(RMNIC)-FE2 from SWITCH
PORT 21 (vlan4)
L6-3(RMNIC)-FE2 from SWITCH
PORT 22 (vlan4)
CABLING OF RACK 1
Shelf 3 (L6-BUSN)
L6-1 (RDTB)-T1/E1 1-10 from DDF
L6-1 (RDTB)-T1/E1 11-21 from DDF
L6-1 (RDTB)-T1/E1 22-32 from DDF
Rack 1 Shelf 3 (BUSN)

Rack 1
Shelf 4 (L7-BGCM)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
GCM GCM
CABLING OF RACK 1
Shelf 4 (L7-BGCM)
L7-GCM-RS485 from L4-11(RMPB)-GPS485
L7-GCM CLK0 GCM CLK1 from L4-14
(RCKG2)-PP2S/16CHIP
L7-GPSSANTA/A from GPS 1/B
L7-GPSSANTB/A from GPS 2/B
L7(GCM)-GCM8K from L4-13(RCKG1)-8KIN2
Rack 1 Shelf 4 (BGCM)

Rack 2
Shelf 1 (BUSN)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
DTB IWFB IWFB IWFB IWFB IWFB IWFB IWFB UIMU UIMU VTCD IWFB SPB SDU
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
RDTB RUIM1 RUIM1
Front plug
Rear plug
CABLING OF RACK 2
Shelf 1 (L3-BUSN)
L3-10(RUIM1)-FE-C1/2
from L4-15(RCHB1)-FE9-
16 (Cabinet 1)
L3-9(RUIM1)-FE-C1/2 from
L4-15(RCHB1)-FE9-16
(cabinet 1)
L3-10(RUIM1)-CLKIN from
L4-14(RCKG2)-CLKOUT
L3-9(RUIM1)-CLKIN from
L4-14(RCKG2)-CLKOUT
L3-1 (RDTB)-T1/E1
1-10 from DDF
L3-1 (RDTB)-T1/E1
11-21 from DDF
L3-1 (RDTB)-T1/E1
22-32 from DDF
Rack 2 Shelf 1 (BUSN)

RACK 2
Shelf 2 (BPSN)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
GLIQV GLIQV PSN4V PSN4V UIMC UIMC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
RPSN RUIM2 RUIM3
Front plug
Rear plug
CABLING OF RACK 2
Shelf 2 (L4-BPSN)
L4-16(RUIM3)-FE2 from
L4-15(RCHB1)-FE 9-16
(Cabinet 1)
L4-15(RUIM2)-FE1 from
L4-15(RCHB1)-FE 9-16
(Cabinet 1)
L4-16(RUIM3)-CLKIN from
L4-14(RCKG2)-CLKOUT
L4-15(RUIM2)-CLKIN from
L4-14(RCKG2)-CLKOUT
L4-15(RUIM2)-FE7 from
switch port 6 (vlan2)
RACK 2 SHELF 2 (BPSN)

SWITCH 2950 BSC SERVER
switch port 3 (vlan2) from L4-12(RMPB)-OMC2 (Cabinet 1)
switch port 4 (vlan2) from L4-11(RMPB)-OMC2 (Cabinet 1)
switch port 5 (vlan2) from L4-9(RUIM2)-FE7 (Cabinet 1)
SWITCH PORT 13 (vlan3) from L6-4(RMNIC)-FE1 (Cabinet 1)
SWITCH PORT 14 (vlan3) from L6-3(RMNIC)-FE1 (Cabinet 2)
SWITCH PORT 21 (vlan4) from L6-4(RMNIC)-FE2 (Cabinet 1)
SWITCH PORT 22 (vlan4) from L6-3(RMNIC)-FE2 (Cabinet 2)
switch port 6 (vlan2) from L4-15(RUIM2)-FE7 (Cabinet 2)
Switch port 24 (vlan1) from MGW server port 24
Swtich port 9 (vlan2) from BSC ALARM
Switch port 11 (vlan2) from client 1
Switch port 12 (vlan2) from client 2
Switch port 10 (vlan2) from CPU server 1
Switch port 15 (vlan3) from MPLS port 16 (PDSN)
Switch port 23 (vlan3) from router 2600
Switch port 19 (vlan4) from CPU server 2
3
4 6
5
10
9
12
11
14
13
15 19
21
22
23
24
Router 2600 BSC Server
Router 2600 from MPLS
DCN port 17
Router 2600 from
switch 2950 port 23
OMP module <-> use straight
Client <-> switch use stright
Router <-> switch use stright
Switch <-> switch use cross
Alarm box <-> switch use straight
Straight :
White orange, orange, white green,
blue, white blue, green, white
brown, brown
Remote
Fe0/0 Fe0/1
BSCB ROUTER
MPLS MGW SWITCH
23 trunk
24 vlan 10
trunk
BSCB SWITCH
24 trunk
1 vlan 10
BSCB SERVER
1
OPTIC FIBER

OPTIC FIBER

BUSN 1 & 2 BUSN 3
BUSN 4
GLIQV
CLKG

X40 X47
Pin 1 & 2 had jumper.
It mean resistance 75 ohm
1 2 3
CLKG

X40 X47
Now Pin 2 & 3 had jumper.
It mean resistance 120 ohm
1 2 3
DTB

S1
S2
S3
S4
S6
S5
S12
S9
S7
S8
S10
S11
S1, S2, S3, S4,
S5, S6, S7, S8,
S9, S12 all 4
pin must off
S10, S11 all 4
pin must on
RDTB
All jumper must take off
TRIB ID, RACK ID & SHELF ID
CABINET 1 RACK 1,2,3

BEFORE AFTER BEFORE
AFTER
1110
(Lampung ID)
0000 (Cabinet 1)
0000 (shelf 1)
1000 (shelf 2)
0100 (shelf 3)
TRIB ID, RACK ID & SHELF ID
CABINET 2 RACK 1 & 2

BEFORE AFTER BEFORE
AFTER
1110
(Lampung ID)
1000 (Cabinet 2)
0000 (shelf 1)
1000 (shelf 2)
0100 (shelf 3)
Rack switcher

0001 (cabinet 2)
0000 (cabinet 1)
Node Switcher

Cabinet 2
3 & 4 jumper
7 & 8 jumper
Cabinet 1
1 & 2 jumper
9 & 10 jumper
Connection between cabinet 1 &
Cabinet 2

DDF ZTE

32 E1 1 DTB module had 32 E1
(10 11 11)
And BSC had 4 module
DTB
It means there are 128 E1
E1 from DTB module

CLIENT CONSOLE

1.Choose application.
2.Choose configuration management.
3.Right click OMMR_3G[100007][Bandar
Lampung] and choose add BSS
4.Choose for device id : 7 and device alias :
Bandar Lampung
5.Right click BSSB[7][Bandar Lampung] and
choose add BSC system
Module of Rack 1

1.Right click physical configuration and
choose add ip rack.
2.Fill for rack :1 and rack type : ip rack
3.Right click IP Rack[1] and fill shelf : 1
and shelf type : BUSN shelf
4.Right click IP Rack[1] and fill shelf : 2
and shelf type : BCTC shelf
5.Right click IP Rack[1] and fill shelf : 3
and shelf type : BUSN shelf
6.Right click IP Rack[1] and fill shelf : 4
and shelf type : GCM shelf
Configuration module of
rack 1 shelf 2

1.Right click shelf 2 port 9 (UIM) and choose add board then
choose for B type : BT_3G_UIM_2
2.Right click shelf 2 port 10 (UIM) and choose add board
then choose for B type : BT_3G_UIM_2
3.Right click shelf 2 port 11&12 (MPl2) and choose add
board then choose at MP board for B type : BT_3G_WPBCB
at MP board
4.Right click shelf 2 port 11 (MPl2) and choose configure
module type then fill module 1 for MT_3G_OMP and fill
module 2 for MT_3G_RPU
5.Right click shelf 2 port 13 & 14 (CLKG) and choose add
board then choose for B type : BT_3G_CLKG
6.Right click shelf 2 port 15 & 16 (CHUB) and choose add
board then choose for B type : BT_3G_CHUB
7.Right click shelf 2 port 1 & 2 (SPCFMP) and choose add
board then choose for Logic type : UT_3G_BSC_SPCF_MP
8Right click SPCFMP and choose config module type and
choose MT_3G_CMP_HRPD
9.Right click shelf 2 port 3 & 4 (MPl2) and choose add board
then choose at MP board for B type : BT_3G_WPBCB at
MP board
10.Right click shelf 2 port 3 (MPl2) and choose configure
module type then fill module 3 for MT_3G_DSMP_HDMP
and fill module 4 for MT_3G_CMP_HDMP
11.Right click shelf 2 port 5 & 6 (MPl2) and choose add
board then choose at MP board for B type : BT_3G_WPBCB
at MP board
12.Right click shelf 2 port 5 (MPl2) and choose configure
module type then fill module 3 for MT_3G_RMP and fill
module 4 for MT_3G_CMP_HDMP
13.Right click shelf 2 port 9 (UIM) and choose configure
MDM type then fill in all MDM type (call, hand off, HRPD
trnsmitt, paging respond, register)
15.Right click all module and choose config module / unit
relationship
Configuration of module rack 1
shelf 1

1.Right click port 9 & 10 and choose add board then choose UT_3G_UIM_T_GXS (Logic type) ; BT_3G_UIM_2 (B type)
2.Right click port 1 & 2 and choose add board then choose UT_3G_DTB (Logic type)
3.Right click port 3,4,5,6,7,8 & 11 and choose add board then choose UT_3G_IWFB (Logic type)
4.Right click port 12,13 & 14 and choose add board then choose UT_3G_VTC_DSP16 (Logic type)
5.Right click port 15 and choose add board then choose UT_3G_SPB_8260 (Logic type)
6.Right click port 16 and choose add board then choose UT_3G_SDU_PPC775_BSS (Logic type)
7.Right click port 17 and choose add board then choose UT_3G_SDU_PPC775_HRPD (Logic type) (for EVDO services)
Configuration of module rack 1
shelf 3

1.Right click port 9 & 10 and choose add board then choose UT_3G_UIM_T_GXS (Logic type) ; BT_3G_UIM_2 (B type)
2.Right click port 7 and choose add board then choose UT_3G_ABPM_1200_FE8_MHPC (Logic type)
3.Right click port 7 and choose 1+1 back up mode for add port 8
4.Right click port 1 and choose add board then choose UT_3G_DTB (Logic type)
5.Right click port 3 and choose board then choose UT_3G_IPCF_1200_FE8 (Logic type)
6.Right click port 3 and choose 1+1 back up mode for add port 4
7.Right click port 5 & 6 and choose board then choose UT_3G_UPCF_1200_FE8 (Logic type)
8.Right click port 15, 16 & 17 and choose add board then choose UT_3G_SDU_PPC775_BSS (Logic type)
9.Right click port 3 and choose configure A12A13 then choose A12
Configuration of module rack 2
shelf 1

1.Right click port 9 & 10 and choose add board then choose UT_3G_UIM_T_GXS (Logic type) ;
BT_3G_UIM_2 (B type)
2.Right click port 1 and choose add board then choose UT_3G_DTB (Logic type)
3.Right click port 2, 8 & 12 and choose add board then choose UT_3G_IWFB (Logic type)
4.Right click port 12 and choose add board then choose UT_3G_VTC_DSP16 (Logic type)
5.Right click port 16 and choose add board then choose UT_3G_SPB_8260 (Logic type)
6.Right click port 17 and choose add board then choose UT_3G_SDU_PPC775_BSS (Logic type)
7.Right click all module and choose config module / unit relationship
Configuration of module rack 2
shelf 2

1.Right click port 15 & 16 and choose add board then choose UT_3G_UIM_GCS (Logic type) ; BT_3G_UIM_2 (B type)
2.Right click port 7 & 8 and choose add board
3.Right click port 1 & 2 and choose UT_3G_GLIQV_USER (Logic type)
Configure CMP & HMP

1.Right click physical configuration and choose configure
CMP
2.Because of there were 2 CMP at shelf 2 port 3 & 4 so
choose unit no 0-7 for module 4 and unit no 8-15 for
module 6
1.Right click physical configuration and choose configure
HMP
2.Select all unit no from 0-15 for module 100
Configure the connection between DSMP and
RMP, modify A9 timing para & unify VTC
workmode

1.Right click physical configuration and choose configure
the connection between DSMP and RMP
2.Change Instance Num : 720 (on line user)
1.Right click physical configuration and choose
modify A9 Timing Para
2.All data default
1.Right click physical configuration and choose unify
VTC workmode
2.All data default
Configure PCM at DTB module

1.Right click rack 1 shelf 1 port 1 (DTB) and choose configure PCM
2.Then add PCM from 0-31 ( E1 from 0-31)
3.Right click rack 1 shelf 1 port 2 (DTB) and choose configure PCM
4.Then add PCM from 32-63 (E1 from 0-31)
5.Right click rack 2 shelf 1 port 2 (DTB) and choose configure PCM
6.Then add PCM from 64-71 (E1 from 0-7)
7.And for DTB module, pick 4 PCM (right click at PCM and choose configuration relay) so
there were 12 PCM which TS 16 use for signalling (so must delete TS 16)
Configure Physical link 2 at SPB
module

1.Right click rack 1 shelf 1 port 15 and choose configure physical link 2
2.SPB have 4 CPU and because there were 2 DTB so there was 8 CPU at rack 1
(change cpuid : 1-4 ; change DTE1 : 0-3 ; change DT unit : 1-2)
3.Right click rack 2 shelf 1 port 16 and choose configure physical link 2
4.SPB have 4 CPU and because there were 1 DTB so there was 4 CPU at rack 2
(change cpuid : 1-4 ; change DTE1 : 0-3 )
Configure GLI/UIM connection at GLI
module
1.Right click rack 2 shelf 2 port 1 (GLI) and choose GLI/UIM connection
2.Connect GLI port : 0, subsystem : 6 to UIM rack 1 shelf 1 port 1 (subsystem 1)
3.Connect GLI port : 1, subsystem : 6 to UIM rack 2 shelf 1 port 1 (subsystem 5)
4.Connect GLI port : 2, subsystem : 6 to UIM rack 1 shelf 1 port 2 (subsystem 3)
Configure SPCFMP

1.Right click rack 1 shelf 2 port 1 (SPCFMP)
and choose SPCF CPU1
2.Choose configure PCF mode and choose
pCF PCF
3.Right click rack 1 shelf 2 port 1 (SPCFMP)
and choose SPCF CPU1
4.Choose configure PCF firewall and A10
Para
5.Fill in for PCF_A10 Value & SPCF
Firewall IP :192.168.201.122
6.Right click rack 1 shelf 2 port 1 (SPCFMP)
and choose SPCF CPU1
7.Choose connection between SPCF and
PDSN (all data default)
8.Choose configure SPCF CPU1 and
choose configure PCFSPI
9.Fill in SPI Value : 100
10.Fill in KeyCoding & KeyDecode :
1234567890ABCDEF

Configure the number of FE ports
of IPCF
1.Right click rack 1 shelf 3
port 3 (IPCF) and choose
configure ports number of
FE (all data default)
2.Right click rack 1 shelf 3
port 3 (IPCF) and choose
configure A12A13 then
choose A12
Configure PDSN

1.Right click physical configuration and choose configure PDSN
2.Fill in IP address and broker Ip same as IP PDSN Jakarta (192.168.49.33)
3.Fill in name : PDSN
4.Fill in location : Jakarta
5.Fill in UDP port : 699
Configure IP Interface

1.Right click physical configuration and choose
configure IP interface
2.Then choose UT_3G_BSC_SPCF_MP
3.Fill in IP address : 192.168.201.122 (A10)
4.Fill in Subnetmask and Broadcastaddr :
255.255.255.255
5.Fill in MAC : 00-D0-D0-A0-00-10
6.Then choose UT_3G_IPCF_1200_FE8
7.Fill in IP address : 192.168.201.124 (A8)
8.Fill in subnetmask : 255.255.255.0
9.Fill in Broadcastaddr : 255.255.255.255
10.Fill in MAC : 00-D0-D0-A0-00-9
Must input again for IPCF :
12.Fill in port : 2
13.Fill in IP address : 192.168.200.100 (A12)
14.Fill in MAC : 00-D0-D0-A0-00-11
Configure Static Route

1.Right click physical configuration
and choose configure static route
2.Fill in route prefix : 192.168.49.0
3.Fill in next hope (MPLS Lampung)
: 192.168.201.121
BSC configuration & MSC configuration

1.Goes to no. 7 signal and choose BSC
configuration
2.Fill in network type : network8[8]
3.Fill in LAC of the network for local office : 30-
00-07-21
4.Fill in test code : 12345678000000
5.Fill in at 24 signalling point; Main signaling
point : 6, Seed signalling point : 61, signaling
point : 5 (free option)
6.Fill in at 14 signalling point; Main signaling
point : 6, Seed signalling point : 61, signaling
point : 5

1.Goes to no. 7 signal and choose MSC configuration
2.Fill in network type : network7[7]
3.Fill in Signaling Link Code; Main Signaling point : 6,
Seed signaling point : 56, Signaling point : 5
4.Fill in test flag : Need tes[1]
5.Protocol type : CHINA[1]
6.Subsystem field : Domestic Signalling Link Code [8]
MTP Configuration

1.Goes to MTP configuration and choose signal
link set (data default)
2.Choose signal link
Because there were 2 SMP module so:
3.Fill in link id : 1 - 12
4.Fill in SMP module id : 4
5.Fill in signalling link code : 0 - 11
So there was 12 signal for module id 4
6.Choose signal route (data default)
7.Choose signal office (data default)
SSN Configuration

1.Choose SSN configuration
2.Add 10 times; office id 0 mean
BSC and office id 1 mean
MSC/MGW
Radio configuration

1.Goes to radio configuration
2.Fill in CDMA channel
frequency 0 : 201 (voice)
3.Fill in CDMA frequency
0bandclass : 800M[0]
4.Fill in CDMA channel
frequency 1 : 242 (EVDO)
5.Fill in CDMA frequency
1bandclass : 800M[0]

BSS Para

1.Choose BSS para
2.Choose BSS parameter
3.Fill in market id : 1
4.Fill in switch number : 1
5.Fill in MS MCC : 510
(Indonesia)
6.Fill MS MNC : 03
(Indonesia)
7.Fill in MS IMSI_11_12 : 03
(Indonesia)
8.Fill in MSC support group
CIC operator indicator : Not
supported (0)
A12 interface parameter at HRPD para
1.Choose HRPD para
2. Choose A12 interface parameter
3.Fill in AN IP address : 192.168.200.100
4.Fill in AAA IP address : 192.168.200.129
Access network parameter & user
rank at HRPD para

1.Choose HRPD para
2.Choose access network parameter
3.Change system identification :
10817
4.Change network identification :
65535
1.Choose HRPD para
2.Choose user rank
3.Add 9 times (data default)
Add BTS (BDS & RFS rack)

1.Right click BSSB[7][Bandar
Lampung] and choose add BTS
2.Choose add IP BTS
3.Fill in system alias (BTS name)
1.Right click physical configuration and
choose add BDS rack
2.Right click one of module and choose add
subrack then choose add down subrack
Add board for shelf 1 of BDS rack

1.Right click SAM board and choose add board then choose add SAM board
2.Right click GCM board and choose add board (2 board)
3.Right click CHM board and choose add board then choose CHM0 board
3,5. Right click CHM0 and choose configure CSM5000 and group id must 0 all
4.Right click CHM board and choose add board then choose CHM1 board (only for EVDO services)
5.Right click CCM board and choose add board (2 board)
6.Right click RIM board and choose add board (2 board)
7.Right click DSM0 board and choose add board then choose add DSM0 board
8.Right click GCM board and choose configure GCM receivable mode ( 1 board only)
9.Right click GCM board and choose configure CCB work mode
10.Right click CHM1 board and choose configure Rlm then fill in RevChips num : 4 (only for EVDO services)
11.Right click CHM1 board and choose configure Flm (data default) (only for EVDO services)
Add board for shelf 1 of BDS rack

12.Right click DSM0 and configure HDLC then choose configure the Ts of HDLC (only for EVDO services)
13.Right click DSM0 and configure UID (only for EVDO services)
14.Right click DTB (BSC rack 1 shelf 3 port 1) and choose configure BSC HDLC then choose configure the Ts
of HDLC (only for EVDO services)
15.Right click ABPM (BSC rack 1 shelf 3 port 7) and choose configure BSC UID then choose configure UID (only for
EVDO services)
16.Right click ABPM (BSC rack 1 shelf 3 port 7) and choose configure the connection between BSC and BTS
Add board for shelf 2 of BDS rack

1.Right click SAM board and choose add board then choose add SAM1 board
2.Right click TRX board and choose add board then choose add TRX board ( 3
board)
3.Right click RMMIE board and choose add board then choose add RMM0 board
4.Right click RMMIE board and choose configure connection between RIM and
RMM
Add board for shelf 3 & 4 of BDS rack

1.Right click RFEA board and choose add board then choose add RFEA board ( 3 board)
2.Right click PIM board and choose add board
3.Right click LPA board and choose board then choose DPA board (3 board)
4.Right click RFEA board and choose configure connection between TRX and RFE_PA then connect ( 3 board)
5.Right click DPA board and choose configure connection between TRX and RFE_PA then connect ( 3 board)
Configure procedural address and
configure UCFSN check at BTSB

1.Right click BTSB[1] and
choose configure procedural
address then add 2 times
1.Right click BTSB[1] and
choose configure UcFSN check
Add cell at radio configuration
1.Goes to radio configuration and fill in country code : 510
(only for EVDO services)
2.Right click radio configuration and choose add cell
3.Choose cell paramater
4.Fill in cell alias : name of BTS
5.Fill in system identification : 10817
6.Fill in network id : 65535
7.Location : 721 (local area Lampung)
8.CI : 14100 (based on planning)
9.PTT dispatch : 0 (random)
10.Pilot PN sequence offset index : 3 (based on planning)
11.Band class : 800M[0]
11.Pilot PN sequence offset index increment: 3
12.Search window size for the remaining set : 8

13.Choose system parameter
14.Fill in registration zone : 721 (local area Lampung)
15.Fill in base station id : 14100 (based on planning)
16.Fill in authentication mode : include authentication data (1)
17.Fill in random challenge value: 123456 (random)
18.Fill in offset of local time from system : 14
19. Fill in maximum slot cycle slot index : 1
Add new carrier at BSS channel

1.Right click BSS cell and choose add
carrier then choose new carrier
2.Fill TRX element Id : 1
3.At carrier parameter, fill in carrier rated
power (0.1dbm) : 400
3.Choose pilot channel (add with data
default)
4.Choose sync channel (add with data
default)
5.Choose page channel (add with data
default)
6.Choose access channel (add with data
default)
HRPD Cell

1.Choose HRPD cell then choose Cell
parameter
2.Fill in cell alias : name of BTS
3.Fill in Pilot PN : 3 (based on planning)
4.Fill in sector id : 0000000000000001
5.Fill in color code : 1
6.Choose cell state parameter
7.Fill in offset of the local time : 14
8.Choose sector hand off parameter
9.Fill in pilot PN sequence increment : 3
10.Right click HRPD cell and choose
add carrier
11.Fill TRX element Id : 1
12.At carrier parameter, fill in carrier
rated power (0.1dbm) : 400
13.Choose control channel (data
default)
14.Choose acces channel (data default)
15.Choose forward traffic channel (data
default)
BSS Cell

1.Choose BSS cell and choose link cell (data based on planning)
2.Choose BSS carrier and choose neighbor cell list then fill in neighbor
transmitt time offset (data based on planning) and fill in neighbor
transmit time offset : 0
ALARM MANAGEMENT

Choose views and choose fault management
then choose alarm management.
At alarm management, we can know and
check all module which had alarm or not.
VERSION MANAGEMENT
1.Choose Views and choose
System tools then choose version
management.
2.Choose Version Func and choose
Query Version then choose Query
running information after that select
the module.
At version management, we can
know the version type of all module
RFS Attenuation Configuration
1.Choose views and
choose System Tools then
choose Dynamic Data
Management
2.Choose RFS Attenuation
Configuration

At here, we can know RFE
transmission power and we
can rise up & down
transmission power with
change attenuation control
value (standard for Rfe
transmission power is 38
dBm)
DATA SYNCHRONIZATION

1.Choose configuration
management
2.Right click OMM_3G and
choose Data Sync

At Data Synchronization,
after we had done
something with module so
we must synchronization
data first
SAVE CONTROL
1.Choose configuration
management
2.Right click OMM_3G and
choose Save control

At Save control, after we had
done something with module
so we can save control
ALARM BOX
Server IP : 129.168.7.10
Alarm IP : 129.168.7.254
Port : 6700
No 7 Signaling Link
Choose Views->System Tools->Dynamic Data Management->Resource Observe-
>MTP SIGNALINK->MTP LINKSET[1]->SMP[4]
good
No 7 Signaling Link
Choose Views->System Tools->Probe->BSSB->BSCB-
>BSC_CMP_HDMP[4]->select R_Office for Table Name-
>View Table.
good
No 7 Signaling Link
1.Check first IP CMP (128.112.35.9)
2.Add your computer IP (ip address : 128.112.35.9 ; subnet mask : 255.0.0.0)
3. Use the command telnet 128.112.35.9
4.Log in : zte
5.Password : zte
6.WPBCB : ShowCallState

bTRegCallbackExist 0
bTMainCmpReqExist 0
bTGetDbConfigExist 0
bTforbid 0
bTa1_4 0
bTa1_13 0
bBSCReset 0
ForbidState: 0
ucA1ResetState: 0
ucSSNState: 0
ucSPState: 0
g_bMainCMP: 1
g_wSelfCMPModuleId: 3
MainCmpCallMainVpid wModule: 3
MainCmpFacilityMainVpid wModule: 3
CONNECTION WITH JAKARTA
Change your ip comp ( ip
address : 192.168.201.122 ;
subnet mask :
255.255.255.248 ; default
gateway : 192.168.201.121)

CONNECTION WITH JAKARTA
IF NOT SUCCSESS :
1, Generally there one folder of 3GPlatOMC in the
path of Release\ip\tool\ of the Server and client,
open it and find 3GPLATWIN_MGT.ini. Open this
file and modify 3 parameters as follows:
SETUPCOMM=1
BoardIpAddr=129.168.7.1This IP address is
OMC IP of OMP module which communicate with
the server, must input it correctly.
LocalIpAddr=IP address (If in the server, set it at
random and just make it be same segment with
BoardIpAddr, such as 129.168.7.20; but if in the
client, this IP address must be same with the IP
address of the client, such as 129.168.7.100).
2, Copy this modified 3gPlatWIN_MGT.ini file to
the folder of WINDOWS in disk C:, but for win2000
system, this folder is WINNT.
3, Run 3GPLATWINNTTCP.exe,
EXECUTEVC.exeINTERPRETPROC.exe
TELSERVER.exe in order in the folder of
3GPlatOMC. (If system prompts that can not
connect to the database, dont click OK and dont
care.)
Input telnet 127.0.0.1 in the Run window and enter
the following interface.(Blue character need to
input by ourselves.)

************************************************************
Welcome to the world of 3GPlatForm!
************************************************************
Username:root
Password:no password
3GPlatForm>en
3GPlatForm#pro
3GPlatForm(config-protocol)#sh i i b
Interface Stat Pro IP Mask
2:1:7:2:250 down down unassigned unassigned
1:1:14:1:1 down down unassigned unassigned
2:1:3:2:250 down down unassigned unassigned
2:1:1:1:250 up up 192.168.200.138 255.255.255.255
3:1:3:1:1 up up 192.168.200.140 255.255.255.0
3:1:3:1:2 down down unassigned unassigned
3:1:3:1:3 down down unassigned unassigned
3:1:3:1:4 down down unassigned unassigned
3:1:7:1:1 up up unassigned unassigned
3:1:7:1:2 up up unassigned unassigned
3:1:7:1:3 up up unassigned unassigned
3:1:7:1:4 up up unassigned unassigned
3:1:7:1:5 up up unassigned unassigned
3:1:7:1:6 up up unassigned unassigned
3:1:7:1:7 up up unassigned unassigned
3:1:7:1:8 up up unassigned unassigned
3:1:7:1:9 up up unassigned unassigned
3:1:7:1:10 up up unassigned unassigned
3:1:7:1:11 up up unassigned unassigned
The meaning of interface is as follows, for example: 2:1:1:1:250
2subsystemcan see through double clicking SPCF module
1modulecan see in IP interface
1unitcan see through double clicking SPCF module
1sunitcan see through double clicking SPCF module
250local portcan see through double clicking SPCF
module

MTP3 Signal Trace
Choose Views System tools Dynamic Data Management
Resource observe - BSSB Trunk PCM Block ( at check
status )
MTP3 Signal Trace
Choose Views System Tools Signal Trace Tool MTP3 Signal Trace
Trace Set
If direction send and receive, It means connection between BSC MGW MSC
already good
MTP3 Signal Trace

Alarm Query
Choose Alarm Management Query Alarm

In Alarm Query, We can check if the problem still continuous or not
Service Observation
Choose Views System Tools Service
Observation Set
If we made call, so we can know ESN and
IMSI number of handset
Signal Trace
Choose Signal Trace
Tools BSS Signal Trace
Trace Set

Fill in Trace type with
Specify BTS.

After we can know IMSI
and ESN phone number
Signal Trace
Choose Signal Trace Tools BSS
Signal Trace Trace Set
Put IMSI phone number first
After that we can check signal trace
Upgrade BSC module
1.Find 3GVER 18.16.04 folder -> release -> IP -> BSC
& BTS folder
2.Put it into ZXOMC -> UMS -> UMS SVR -> Version
3.Choose add version :
a. Choose BSC CPU WPBCB OMP 755
WPBCB
b. Choose BSC FPGA WPBCB 040401
WPBCB
c. Choose BSC CPU WPBCB RPU 755
WPBCB
d. Choose BSC CPU WPBCB SPCF
e. Choose BSC CPU WPBCB RMP
f. Choose BSC CPU WPBCB CMP
g. Choose BSC CPU DSMP HDMP
h. Choose BSC CPU HMP - HDMP
4.Choose configure OMP
a. Choose OMP Left, double click then choose 04
and right click choose configuration
b. Choose OMP Right, double click then choose 04
and right click choose configuration
c. Choose FPGA Left, double click then choose 04
and right click choose configuration
d. Choose FPGA Right, double click then choose 04
and right click choose configuration
Then reset both OMP at same time

5.Choose active version
a. RPU
b. HDMP_DSMP
c. CMP_HDMP
d. RMP
e. CMP_HRPD
f. BSC_SPCF
Then reset all MP
6.Choose active version
a.CPU/ UIM2/ MDM/ 755/ GCS
b.CPU/ UIM2/ UIM/ 755/ GXS
c.FPGA/ UIM2/ 040204/ UIM2/ FPGA
Then reset all UIM module
d.CPU/ DTB/ DTB/ 852/ DTB
Then reset all DTB module
e.CPU/ VTCD/ VTC/ 8260
f. DSP/ EVRC IND/ VTCD
Then reset all VTCD module
g.CPU/ WPBCA/ RLSASDU/ 755/ SDU BSS
h. CPU/ WPBCA/ HSDU/ 755/ SDU- HRPD
i. FPGA/ WPBCA/ 030800/ FPGA
Then reset all SDU module

Upgrade BSC module
5.j. CPU/ SPB/ SPB/ 8260/ SPB8260
Then reset all module SPB
k. CPU/ PSN/ PSN/ 860/ PSN4V
Then reset all module PSN
l. CPU/ MNIC/ UPCF/ BEARM/ UPCF Microcode
m. CPU/ MNIC/ UPCF/ BEARM/ UPCF CPU
Then reset all module UPCF
n. CPU/ MNIC/ IPCF/ BEARM/ IPCF Microcode
o. CPU/ MNIC/ IPCF/ BEARM/ IPCF CPU
Then reset all module IPCF
p. CPU/ MNIC/ ABPM/ BEARM/ ABPM Microcode
q. CPU/ MNIC/ ABPM/ BEARM/ ABPM CPU
r. CPU/ MNIC/ ABPM/ 755/ ABPM
s.FPGA/ MHPC/ 031101/ FPGA
Then reset all module ABPM
t. CPU/ IWFB/ IWF/ 8250
u. DSP/ IWFB/ IWFB
Then reset all module IWFB
v. CPU/ GLIQV/ GLI/ XSCALE/ Microcode
w. CPU/ GLIQV/ GLI/ XSCALE/ Microcode
x. CPU/ GLIQV/ GLI/ XSCALE/ CPU2
y. CPU/ GLIQV/ GLI/ XSCALE/ CPU
z. FPGA/ GLIQV/ 040202/ GLIQV
Then reset all module


A. CPU/ CHUB/ CHUB/ 8245/ CHUB
B. BTS/ MCU/ GCM1/ BSC GCM1
C. BTS/ FPGA/ TFS/ GCM1/ 00002
For B & C then choose deliver version and choose MCU and
choose GCM
Upgrade BTS module
Upgrade BTS module
a. Choose add version :
1. CPU/ CCM/ CCM/ 755/ CCM
2. CPU/ RMM/ RMM/ 8245/ RMM0
3. CPU/ CHM1X/ CHM1X/ 755/ CHM1X
4. CPU/ DSM/ 8245/ DSM
5. CPU/ TRX/ TRX/ 850/ TRX
6. MCU/ SAM/ SAM0
7. MCU/ GCM0/ GCM
FPGA/ TFS/ GCM0/ D47/ GCM0
8. MCU/ RIM0/ RIM
9. MCU/ SAM1/ SAM1
10. MCU/ RFE_A/ RFE_A
11. MCU/ PIM/ PIM
12. MCU/ DPA/ DPA
Upgrade BTS module
1.Choose Version management
2.Choose Deliver Version
3.Choose Create Deliver Task Monitor then choose cancel
4.Choose CPU first
5.Choose 5 modules (CCM, RMM, CHM1X, DSM, TRX)
6.Choose Mate Syn
7.Choose All IP board and cancel BTSA board
8.Choose only UT_CCM_BIN only
9.Choose active version then choose cancel
10.Choose BTS node
11.Choose All IP Control board
12.Choose activate CPU version
13.Choose active version then choose cancel
14.Choose BTS node
15.Choose All IP Controlled Board
16.Choose Board Type Selection
17.Choose 3 modules (CHM0, DSM, TRX) and activate
CPU version
18.Reset board normally CCM master
19.Choose Active version
20.Choose BTS Node
21.Choose All IP Control board
22.Choose activate version
23.Reset board normally CCM master
24.Reset board normally RMM, CHM0, DSM0
25.Choose Query Version
26.Choose Query Running Information
27.Choose 5 modules (CCM, RMM, DSM, TRX, CHM)
28.Choose Deliver Version
29.Choose MCU
30.Choose 7 modules (SAM0, GCM, RIM0, SAM1, RFE_A,
PIM, DPA)
31.Choose Query Version
Debugging AN-AAA
1.Fill in IP address computer
IP address : 192. 168. 200. 110
Subnet mask : 255.255.255.0
2.Choose SQL Server Enterprise Manager Security and
make sure that at authentication is SQL Server and Windows
3.Choose Login General
Fill in Name : aaa
Choose : SQL Server Authentication and fill in password : aaa
4.Choose Login Server roles System administrators
5.Choose Login Database Access pubs
6.Install radius-winE\DISK1\setup.exe
7.At Database option
Fill in SQL Server Name : MACHINENAME
Fill in Database name : RasA100
Fill in user name, user password, repeat password : aaa
8.At Version option
Fill in Server Run Mode : 2-AN-AAA Only
Fill in SNMP Manager IP, DNS Server IP, Wap Gate Ip, PPS
address : 1.1.1.1
9.install-config\install.bat
10.At Select Setup Module, choose Configuration module,
DBIO module, agent module
11.At Set Module Information
Fill in area code : 21
Fill in post code : 200
Fill in local module : 129
12.Change IP address computer
IP address : 192. 168. 200. 129
Subnet mask : 255.255.255.0
13.At Set Module Information
Fill in Remote module code : 201
Fill in Remote module IP address : 192.168.200.201
14.At Set Database Information
Fill in Database server IP or name : 192.168.200.129
Fill in Database : RasA100
Fill in User name and password : aaa
Fill in Database type : MS SQL Server
15. Install ZXPDSS-A100 Radius Configure
Debugging AN-AAA
16.At Radius Configure database connection
Fill in Database server name : MACHINENAME
Fill in Database driver : MSSQL
Fill in Database name : RasA100
Fill in Database account and password : aaa
17.At Radius Configure Login
Fill in operator code and operator password : admin
18.At security association
Fill in ip address : 192.168.200.129
Fill in Type : Radius
Fill in Secret Key : 1234567890ABCDEF
Fill in name : AN-AAA
19.At Manufacture ID setting
Fill in Manufacture ID and setting : zte
20.At new IMSI
Fill in IMSI : 510030303030303
Fill in MDN : 627218100100
Fill in User name : EVDO
21.At New NAI user
Fill in NAI user name : 0303030303
Fill in password & confirm password :


MODIFY IMSI at KYOCERA
1.Press 111111
2.Choose programming
3.Press 000000
4.Choose ESN (cant change)
5.Choose Basic NAM1
5a.Choose phone number (8600000000)
5b.Choose NAM1 Home SID (10817)
5c.Fill in NAM1 Name : Starone
6.Choose Extra NAM1 Info
6a.Choose Country Code : 510
6b.Choose NMSID : 038600000000
6c.Choose true IMSI : 510038600000000
6d.Choose CDMA NAM1
6d1.Choose Directory # : 8600000000
6d2.Choose SID/NID : 01=10817 / 65535
6d3.Choose Primary CHA : 201
6d4.Choose Secondary CHA : 283
6d5.Choose Primary CHB : 384
6d6.Choose Secondary CHB : 777
6d7.Choose Home Sys Reg : No
6d8.Choose Forn SID Reg : No
6d9.Choose Forn NID Reg : No
7.Choose Slot Cycle Index : 2
Telnet ABPM
Must put ip address same segment like
ABPM at advanced
Then telnet ip ABPM
Login : ZTE
Password : ZTE
MNIC_J> ldm_print_all
Performance Management
1.Views Performance Management Statistics
2.BSS Global Voice Call Statistics Execute Statistics
BSS Global Voice Call Sum
BSS Global Voice call Success Number
BSS Global Voice Call Success Rate ( % )
Markov Call
From the phone :
1.System Tools Network Performance Test
2.NPT 3G BSS
3.97DTest Call Enable 1/2 rate
From the system :
3.97DTest Manual Call Service type : M_SO_Markov3 ( BSC Call )
4.Fwd RC : 3
5.Add IMSI
4.97DTest Call Set Service type : Markov3
Result
Know how to debug BSC, but still need support
from the expert if there is any problem
Know how to inform to the expert if there is any
problem during debugging or configuring BSC
Have knowledge about BSC, but still need to
learn
Can work together with expert, local engineer
and Indosat engineer during built STARONE
system
Problems Encountered
Lack of training
Need to learn more about BSC (debug
and configure)
Cant understand all of document in
spesific
Need another project for more knowledge
Future Plan
Keep on learning on ZTE CDMA 2000 1x
Network System, background and
foreground, and also debugging BSC
Learn another equipment. Not only BSC,
but MGW, MSCe and HLRe also
Always keep good relationship with other
ZTE engineers, local & Chinesse
engineers and Indosat engineers

Thanks
?