10. Carefully push the remaining wire into the hole. Push the Ledpod
into the hole. The witness mark on the Ledpod should be pointed
towards the pathway. If the Ledpod does not push in, remove and
check spring alignment (g. 6).
2. Turn off the power before terminating the Driver or xtures. Never
perform electrical work on a live circuit.
12. Connect the driver to the AC power mains using location appropriate electrical terminations. Ground the driver and enclosure using
the mounting studs inside the enclosure.
5. Pull a loop of the 24 VDC wires out of the 25mm Ledpod hole (g.
2).
6. Install the retaining spring (g. 3).
7. Install the Scotchlocs to the 24 VDC main wires and the step
down transformer (fig. 4). Ensure that the polarity of wires from
the step-down transformer (+ = red, - = black) connect to the
correct polarity main 24 VDC wires.
8. Carefully push wires, Scotchlocs, and step down transformer
into the hole (g. 5).
9. Plug the Ledpod into the step-down transformer.
g. 1
g. 2
g. 3
24 VDC wires
Spring Clip
g. 5
g. 4
g. 6
Scotchlocs
Step-down
transformer
2013
Soft Start
Relay
Soft Start
Relay
SURFACE MOUNT
Cover Flange
With or Without
Set Screw
WIRE SIZE
10
AWG
12
AWG
14
AWG
16
AWG
18
AWG
DISTANCE
120'
71'
46'
29'
18'
13/16"
1"
24 VDC
100W
Driver
41/2"
Concrete
Rockite
or Kwixset
Concrete
or
conduit