You are on page 1of 6

Flat Slab Design

(According to BS 8110:part 1:1985)

Lx

Ly

DL

IL

6.6

6.6

6.3

Most Bottom layer

Column section area

360000

Design
Load(kN/m2
)
15.22

Design
Load(kN)
663

f cu

Dim

30

10

Long way R/f - L


Short way R/f - S
Breadth of effective moment transfer strip, be

mm2

Effective diameter of column, hc


Effective Span of Panel, l,

677

Maximum value for hc =

mm

long way
short way

Design moments:
(i) Long way
(i) Outer support moment
(ii) Near centre of first span moment
(iii) First interior support moment
(iv) Centre of interior span moment
(v) Interior support moment
(i) Short way
(i) Outer support moment
(ii) Near centre of first span moment
(iii) First interior support moment
(iv) Centre of interior span moment
(v) Interior support moment
Devision of moments between strips:

6.15 m
6.15 m

Maximum moment transferred to th


163.06
338.35
256.82
289.43
224.20

width of strip (m)


Outer support moment
Near centre of first span moment
First interior support moment
Centre of interior span moment
Interior support moment

(i)
Adusted outer sup
(ii)Adusted near centre of

kNm
kNm
kNm
kNm
kNm

Maximum moment transferred to th


163.06
338.35
256.82
289.43
224.20

kNm
kNm
kNm
kNm
kNm

Long way
Middle strip

(i)
(ii)
(iii)
(iv)
(v)

Slab Depth
200

3.30
39.02
153.83
64.20
130.24
56.05

Column
strip
3.30
117.05
188.01
192.61
159.19
168.15

(i)
Adusted outer sup
(ii)Adusted near centre of

Short way
Middle
strip
3.30
34.56
115.57
64.20
130.24
56.05

Column
strip
3.30
103.68
141.25
192.61
159.19
168.15

Design of R/fs:
(i) Long wa (Middle Strip)
(i) Outer support moment

2
M (kNm/m) k =M/bd fcu

11.82

0.0136

Z (mm)

As,req (mm2/m)

161.5

183

(ii)
(iii)
(iv)
(v)

Near centre of first span moment


First interior support moment
Centre of interior span moment
Interior support moment

46.62
19.46
39.47
16.99

0.0538
0.0224
0.0455
0.0196

(Column Strip)
M
Outer support moment
Near centre of first span moment
First interior support moment
Centre of interior span moment
Interior support moment

2
(kNm/m) k =M/bd fcu

(iii) Short wa(Middle Strip)


M
(i) Outer support moment
(ii) Near centre of first span moment
(iii) First interior support moment
(iv) Centre of interior span moment
(v) Interior support moment

2
(kNm/m) k =M/bd fcu

(iv) Short wa(Column Strip)


M
(i) Outer support moment
(ii) Near centre of first span moment
(iii) First interior support moment
(iv) Centre of interior span moment
(v) Interior support moment

2
(kNm/m) k =M/bd fcu

(ii) Long wa
(i)
(ii)
(iii)
(iv)
(v)

Check for Deflection:


Considering long way span,
Total moment at midspan
Total As.req
Total As.prov

Z (mm)

0.0409
0.0657
0.0673
0.0556
0.0588

10.47
35.02
19.46
39.47
16.99

As,req (mm

161.5
156.5
156.2
158.7
158.1
Z (mm)

0.0121
0.0404
0.0224
0.0455
0.0196

31.42
42.80
58.37
48.24
50.96

732
301
613
263

549
910
934
759
806
As,req (mm

161.5
161.5
161.5
160.9
161.5
Z (mm)

0.0362
0.0494
0.0673
0.0556
0.0588

162
542
301
613
263
As,req (mm

161.5
160.1
156.2
158.7
158.1

Corner panel
103.59
1641.45
4021.24

Interior panel
87.71
1372.16
3619.11

Modification factor for tension R/F

1.09
117.36
2.06

0.92
109.00
2.24

Allowable Span/Eff.depth

48.18

52.31

Actual Span/Eff.depth

38.82

38.82

Deflection Ok

Deflection Ok

M/bd2
fs

Check for Shear:

35.47
56.97
58.37
48.24
50.96

159.2
161.5
160.9
161.5

486
668
934
759
806

Cover

dlong

dshort

daverage

Drop (m)

25

170

160

165

1200

mm

1650

mm

hc is ok

moment transferred to the edge/corner column,Mt,max

Adusted outer support moment


Adusted near centre of first span moment

156.06 kNm
156.06 kNm
341.84 kNm

moment transferred to the edge/corner column,Mt,max

Adusted outer support moment


Adusted near centre of first span moment

138.24 kNm
138.24 kNm
350.75 kNm

As,min = 0.13Ac/100 =260


As,req (mm2/m)
183

As, prov (mm2/m)


10

300

262

732
301
613
263

16
10
16
10

As,req (mm2/m)
549
910
934
759
806

10
16
12
16
12

2011
314
1608
314

@
@
@
@
@

125
100
100
100
125

628
2011
1131
2011
905

As, prov (mm2/m)


10
10
10
10
10

As,req (mm2/m)
486
668
934
759
806

100
250
125
250

As, prov (mm2/m)

As,req (mm2/m)
162
542
301
613
263

@
@
@
@

@
@
@
@
@

300
125
250
125
250

262
628
314
628
314

As, prov (mm2/m)


10
10
12
10
12

@
@
@
@
@

150
100
100
100
125

524
785
1131
785
905

You might also like