You are on page 1of 10

457

FIBER
SENSORS

Small U-shaped Micro Photoelectric Sensor

Amplifier Built-in

PM-44 SERIES PM-54 SERIES


Related Information

General terms and conditions............ F-17


Glossary of terms / General precautions........ P.1359~ / P.1405

Sensor selection guide................... P.441~


Koreas S-mark............................... P.1410

LASER
SENSORS
PHOTOELECTRIC
SENSORS

Conforming to
EMC Directive

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

Recognition

Certified
(Some models only)

LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

panasonic-electric-works.net/sunx

PNP output
type available

STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS

Enables space saving and quick installation!


Equipped with two independent outputs

Quick fitting hook-up connector

All models are equipped with two independent outputs


Light-ON and Dark-ON.
Hence, one model suffices even if the output is to be
used differently, depending upon the location of use.
Also, since two independent outputs have been
provided, cumbersome handling of the output conversion
control input, or fear of logic inversion due to a cable
break, is eliminated. The sensor can be connected to the
existing wiring as it is.

Easy to maintain connector


type models are available. Its
exclusive connector is the hookup connector.
Since only crimping with
exclusive pliers is to be done,
cumbersome soldering or
insulation is absolutely not
required.
Further, connector attached
cable is also available.

Example of connection with a commercial intermediate connector

Commercial intermediate
connector

Selection
Guide
U-shaped
Convergent
Reflective

PM-24
PM-44/PM-54

Quick connection to the


sensor.

+V
0V
Output 1 (Light-ON)
Output 2 (Dark-ON)

PM-64

Crimp the connector on the


cable.

Just connect the cable of the used


output (either Light-ON or Dark-ON).

To PLC

Connected device side


can be left as it is.

Note: Ensure to insulate the unused output wire.

APPLICATIONS
Sensing the starting point and
overrun of a moving body
Overrun sensing
Dog

Wide model variety


A wide variety of 12 shapes and 24 models is available.
You may select from this wide range to suit the mounting
conditions.

Starting point sensing

Meets global requirements


Conforms to Europes EMC Directive and obtains UL
Recognition.
The NPN output type with cable (excluding 3 m
9.843 ft cable length type) has also obtained Koreas Smark certification.
Both, NPN and PNP output models are available.

Overrun sensing

Starting point
and overrun is
sensed using
the dog on the
base.

Small U-shaped Micro Photoelectric Sensor

PM-44 SERIES PM-54 SERIES

ORDER GUIDE

458
FIBER
SENSORS
LASER
SENSORS

Type

Appearance (mm in)

Sensing range

K type

7 0.276

26.2
1.031

25.4
1.000

T type

26.2
1.031

L type

26
1.024

With cable
Y type

13.4
0.528

F type

NPN open-collector transistor

PM-K44P

PNP open-collector transistor

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

PM-T44

NPN open-collector transistor

PM-T44P

PNP open-collector transistor

PM-L44

NPN open-collector transistor

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS

18.5
0.728

25.5
1.004

PM-L44P

PNP open-collector transistor

PM-Y44

NPN open-collector transistor

PM-Y44P

PNP open-collector transistor

PM-F44

NPN open-collector transistor

PM-F44P

PNP open-collector transistor

PM-R44

NPN open-collector transistor

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE

13.2 0.520
26.2
1.031

13.7
0.539

R type

13.2 0.520

26.2
1.031

13.7
0.539

PHOTOELECTRIC
SENSORS

SENSOR
OPTIONS

15.5 0.610

K type

PM-K44

Output operation

15.5 0.610
26
1.024

T type

Output

LIGHT
CURTAINS

13.7 0.539

Small

Model No.

5 mm 0.197 in
(fixed)
7 0.276
22.2
0.874

25.4
1.000

13.7 0.539

26
1.024

22.2
0.874

PM-R44P

PNP open-collector transistor

PM-K54

NPN open-collector transistor

PM-K54P

PNP open-collector transistor

LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES

Incorporated with
2 outputs:
Light-ON / Dark-ON

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

PM-T54

NPN open-collector transistor

PM-T54P

PNP open-collector transistor

PM-L54

NPN open-collector transistor

Convergent
Reflective

PM-L54P

PNP open-collector transistor

PM-64

PM-Y54

NPN open-collector transistor

PM-Y54P

PNP open-collector transistor

PM-F54

NPN open-collector transistor

PM-F54P

PNP open-collector transistor

PM-R54

NPN open-collector transistor

PM-R54P

PNP open-collector transistor

Selection
Guide

13.4
0.528

F type

14.5
0.571
15.5 0.610

Y type

L type

15.5 0.610
26
1.024

21.5
0.846

PM-24

13.2 0.520
13.7
0.539

22.2
0.874

13.2 0.520

R type

With connector

U-shaped

13.7
0.539

22.2
0.874

PM-44/
PM-54

459
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS

Small U-shaped Micro Photoelectric Sensor

PM-44 SERIES PM-54 SERIES

ORDER GUIDE
3 m 9.843 ft cable length type
3 m 9.843 ft cable length type (standard: 1 m 3.281 ft) is also available.
When ordering this type, suffix -C3 to the model No.
(e.g.) 3m 9.843 ft cable length type of PM-K44 is PM-K44-C3.

AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS

OPTIONS
Designation
Connector

SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS

Model No.
CN-14

Connector for soldering

CN-14H

This connector can be hooked-up on 0.08 to 0.2 mm2 cable


simply in one grip.
Wire diameter: 0.7 to 1.2 mm 0.028 to 0.047 in

CN-14H-2

Suitable for UL standard cable.


This connector can be hooked-up on 0.18 to 0.22 mm2 cable
simply in one grip.
Wire diameter: 1.2 to 1.52 mm 0.047 to 0.060 in

Hook-up
connector

MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE

CN-14H-C1
Connector
attached cable

LASER
MARKERS

CN-14H-C3

PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide
U-shaped
Convergent
Reflective

PM-64
PM-24
PM-44/
PM-54

Hook-up pliers

Description

CN-HP

Length:
1 m 3.281 ft
Net weight:
20 g approx.
Length:
3 m 9.843 ft
Net weight:
65 g approx.

For the connector type, with 0.18 mm2


4-core cabtyre cable
Cable diameter: 3.8 mm 0.150 in

These are exclusive pliers for hook-up connectors CN-14H and


CN-14H-2.

Connector

Hook-up connector

Connector attached cable

Hook-up pliers

CN-14

CN-14H
CN-14H-2

CN-14H-C1
CN-14H-C3

CN-HP

Small U-shaped Micro Photoelectric Sensor

PM-44 SERIES PM-54 SERIES

SPECIFICATIONS

Model No.

Item

FIBER
SENSORS

With cable

With connector

NPN output

PM-44

PM-54

PNP output

PM-44P

PM-54P

Sensing range

5 mm 0.197 in (fixed)

Minimum sensing object

0.05 mm 0.002 in or less

Repeatability

0.03 mm 0.001 in or less

Supply voltage

Output

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

15 mA or less
<NPN output type>
NPN open-collector transistor
Maximum sink current: 50 mA
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 0.7 V or less (at 50 mA sink current)
0.4 V or less (at 16 mA sink current)

Utilization category

<PNP output type>


PNP open-collector transistor
Maximum source current: 50 mA
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 0.7 V or less (at 50 mA source current)
0.4 V or less (at 16 mA source current)

DC-12 or DC-13

Output operation

Under light received condition: 20 s or less, Under light interrupted condition: 100 s or less
(Response frequency: 1 kHz or more) (Note 2)

Operation indicator

Vermilion LED (lights up under light received condition)

Pollution degree

3 (Industrial environment)

Ambient temperature

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS

Incorporated with 2 outputs: Light-ON / Dark-ON

Response time

MICRO
PHOTOELECTRIC
SENSORS

LIGHT
CURTAINS

5 to 24 V DC 10 % Ripple P-P 10 % or less

Current consumption

PHOTOELECTRIC
SENSORS

AREA
SENSORS

0.8 1.8 mm 0.031 0.071 in opaque object

Hysteresis

Environmental resistance

LASER
SENSORS

Small

Type

460

MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE

25 to +55 C 13 to +131 F (No dew condensation or icing allowed), Storage: 30 to +80 C 22 to +176 F

Ambient humidity

LASER
MARKERS

35 to 85 % RH, Storage: 35 to 85 % RH

Ambient illuminance

Fluorescent light: 1,000 x at the light-receiving face

EMC

PLC /
TERMINALS

EN 60947-5-2

Voltage withstandability

1,000 V AC for one min. between all supply terminals connected together and enclosure

HUMAN
MACHINE
INTERFACES

Insulation resistance

50 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure

Vibration resistance

10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each

FA
COMPONENTS

Shock resistance
Emitting element

Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated)

Material

Enclosure: PBT, Slit cover: Polycarbonate, Terminal part [PM-54(P) only]: Solder plated
0.09 mm2 4-core cabtyre cable, 1 m 3.281 ft long

Cable
Cable extension

MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.

Weight

Net weight: 15 g approx.

Net weight: 3 g approx.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F.
2) The response frequency is the value when the disc, given in the figure below, is rotated.

Disc

Disc

1.8 mm 0.071 in

Selection
Guide
U-shaped
Convergent
Reflective

PM-64
t = 0.2 mm 0.008 in
1.6 mm 0.063 in

1.6 mm 0.063 in

PM-24
PM-44/
PM-54

461

Small U-shaped Micro Photoelectric Sensor

I/O CIRCUIT AND WIRING DIAGRAMS

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS

PM-44PM-54

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES

Wiring diagram
Brown

Color code for cable type (Note 2)


(Brown) +V

ZD1
Sensor circuit

LIGHT
CURTAINS

NPN output type

I/O circuit diagram

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

PM-44 SERIES PM-54 SERIES

ZD2

(Black) Output 1
Load
(Note 1,3)
50 mA max.
(White) Output 2 (Note 1,3)

Tr1

Tr2

Load

5 to 24 V DC
10 %

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide
U-shaped
Convergent
Reflective

PM-64

5 to 24 V DC
10 %

Color code

Output operation

Output 1

Black

Light-ON

Output 2

White

Dark-ON

PM-44PPM-54P

PNP output type

I/O circuit diagram

Wiring diagram
Brown

Color code for cable type (Note 2)

Black

ZD1
Tr1
ZD2

50 mA max.
(Black) Output 1 (Note 1,3)
50 mA max.

Tr2

(White) Output 2 (Note 1,3)


Load
(Blue) 0 V
Internal circuit

Load

5 to 24 V DC
10 %

Blue

Symbols ZD1, ZD2: Surge absorption zener diode


Tr1, Tr2 : PNP output transistor

SENSING CHARACTERISTICS (TYPICAL)


PM-L44(P)/K44(P)PM-L54(P)/K54(P)
Sensing position

DarkON
7 mm
0.276 in

8.5 mm
0.335 in

2.9 mm
0.114 in
LightON 0

Beam
axis
1
2
3
0.039
0.079
0.118
Operating point (mm in)

4
0.157

LightON 0

1
2
3
0.039
0.079
0.118
Operating point (mm in)

Load

5 to 24 V DC
10 %

Load

Output operation

Users circuit

Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) The color code of the connector attached cable is also the same.
3) Ensure to insulate the unused output wire.

DarkON

White

PM-24
PM-44/
PM-54

Symbols ZD1, ZD2: Surge absorption zener diode


Tr1, Tr2 : NPN output transistor

Sensor circuit

HUMAN
MACHINE
INTERFACES

Output operation

Users circuit

(Brown) +V

PLC /
TERMINALS

Load

Blue

Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) The color code of the connector attached cable is also the same.
3) Ensure to insulate the unused output wire.

ENDOSCOPE
LASER
MARKERS

Load

White

50 mA max.

(Blue) 0 V

Internal circuit

Black

4
0.157

Color code

Output operation

Output 1

Black

Light-ON

Output 2

White

Dark-ON

Small U-shaped Micro Photoelectric Sensor

PM-44 SERIES PM-54 SERIES

PRECAUTIONS FOR PROPER USE

Refer to General precautions.

Never use this product as a sensing device


for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.

Mounting
When fixing the sensor with screws, use M3 screws and
the tightening torque should not exceed the values given
below.
Further, use small, round type plain washers (6 mm
0.236 in).

PM-54(P)

Tightening torque
0.5 Nm

PHOTOELECTRIC
SENSORS

Cable extension
Cable extension is possible up to an overall length of
100 m 328.084 ft with a 0.3 mm2, or more, cable.
However, since a voltage drop shall occur due to the
cable extension, ensure that the power supply voltage
at the end of the cable attached to the sensor or at the
sensor terminals is within the rating.
Total cable length 100 m 328.084 ft

Make sure to connect terminals correctly as


the sensor does not incorporate a reverse
polarity protection circuit.
Further, the output is not incorporated with a
short-circuit protection circuit. Do not connect
it directly to a power supply or a capacitive
load. Faulty wiring may result in damage.

PM-44(P)

FIBER
SENSORS
LASER
SENSORS

All models

Model No.

462

Cable attached
to sensor or connector terminals

+V

Extension cable

Output

5 to 24 V DC
10 %

But, when the overall cable length, including the cable


attached to the sensor, is as given below, there is no
need to confirm the voltage.
Conductor cross-section area of
extension cable

Total cable length

0.08 to 0.1 mm2

Up to 5 m 16.404 ft

0.2 mm2

Up to 10 m 32.808 ft

0.3 mm2

Up to 20 m 65.617 ft

Spring washer
Plain washer
Outer diameter
6 mm
0.236 in

Supply voltage: 4.5 V or more

M3 screws

Others
Since the sensor is intended for
use inside machines, no special
countermeasures have been taken
against extraneous light. Take care
that extraneous light is not directly
incident on the beam receiving section.
Do not use during the initial transient
time (50 ms) after the power supply is
switched on.

AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

0V

MICRO
PHOTOELECTRIC
SENSORS

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide
U-shaped
Convergent
Reflective

PM-64
PM-24
PM-44/
PM-54

463

Small U-shaped Micro Photoelectric Sensor

PRECAUTIONS FOR PROPER USE

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS

Cautions in plugging or unplugging a connector

Crimping of hook-up connectors CN-14H and CN-14H-2

Do not plug or unplug a connector more than


10 times.
Be sure not to give stress more than 5 N to
a terminal of both a connector and a sensor.
If you do not follow the above cautions, it will
cause a poor contact.

AREA
SENSORS
LIGHT
CURTAINS

INDUCTIVE
PROXIMITY
SENSORS

Refer to General precautions.

PM-54PM-54P

MICRO
PHOTOELECTRIC
SENSORS

PRESSURE /
FLOW
SENSORS

PM-44 SERIES PM-54 SERIES

Insert a connector straight into a


sensor until the connector lug is
locked by the sensor hook.

CN-14H

CN-14H-2

Conductor crosssection area

0.08 to 0.2 mm2


(AWG28 to AWG24)

0.18 to 0.22 mm2


(AWG25 to AWG24)

Wire diameter

0.7 to 1.2 mm
0.028 to 0.047 in

1.2 to 1.52 mm
0.047 to 0.060 in

Wire insulation
material

Procedures of plugging or unplugging a connector

PARTICULAR
USE
SENSORS

Model No.
Item

Vinyl chloride or soft polyethylene

Hook
Lug

Wire diameter

SENSOR
OPTIONS

Conductor cross-section area

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

When unplugging, give as much


stress as a connector lug can
be relieved from a hook. Then
unplug it.

5 N or less

Crimping method
1

STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

U-shaped

PM-64
PM-24
PM-44/
PM-54

Cable sheath
15 mm 0.591 in or more

Arrangement of connector terminals


+V: +V
+V

0V

1: Output 1 (Light-ON)
2: Output 2 (Dark-ON)

(Note) Power supply

0V: 0 V

Note: Wire at Pin No.1 or 2 as per requirement.

Soldering (Both connector CN-14 and sensor)


If soldering is done directly on the terminals, strictly
adhere to the conditions given below.

Soldering time

Convergent
Reflective

Lead wire
(Do not strip the wire insulation.)

Caution: Be sure to hold a


connector when plugging
or unplugging it. Do
not hold a terminal or
a cable when plugging
or unplugging the
connector.
Otherwise, it will cause a
poor contact.

Soldering temperature

Selection
Guide

Strip the cable sheath 15 mm 0.591 in, or more, and


insert the wires into the connector insertion holes till the
wire tips reach the end.

3 sec. or less

Soldering position

Sensor

+V 1

260 C 500 F or less

Refer to the below figure

Connector

0V

+V

0V

1.5 mm
0.059 in
Soldering
position

Crimp with the exclusive hook-up pliers CN-HP.

Notes: 1) When attaching or


detaching the connector
fitted with a cable, make
sure to hold the connector
firmly before proceeding.
2) After crimping, do not pull
on the cable.

Caution: M
 ake sure to use the exclusive hook-up
pliers CN-HP.Commercially available pliers
cannot be used.

Prior to using the sensor, affix the cable in a way as to


avoid direct stress on the crimped part.

Small U-shaped Micro Photoelectric Sensor

DIMENSIONS (Unit: mm in)


Sensor

PM-T44PM-T44P

Sensor

2-3.2 0.126 mounting holes

1 0.039

6.4
0.252

Operation indicator
(Vermilion)
2.9 0.114

6.4
0.252

Beam axis

8.5 0.335

13.8 0.543

26.2
1.031 11
0.433 10.8
0.425

4.3
0.169
3.2
0.126

9.5 0.374

4.8
0.189

2.7 0.106 cable, 1 m 3.281 ft long

2.5
0.098

Sensor

26 1.024
19 0.748
1 0.039

3.2
0.126
7
0.276

2
0.079

1
0.039

7
0.276

Beam axis

18.5
0.728 10.8
0.425

2-mounting oblong holes

25.5
1.004

Operation indicator
(Vermilion)
4.8
0.189

2.9
0.114

13.4
0.528

7.2
0.283
19
0.748

3.6
0.142

3.3
0.130
6.5
0.256

3.5 0.138

ENDOSCOPE

1
0.039

4.8
0.189

2.5
0.098

6.5
0.256

8.5
0.335
26.2
1.031

2 0.079
Operation indicator
(Vermilion)

9
0.354

13.2
0.520
6.4
0.252
7
0.276

UV
CURING
SYSTEMS

PM-R44PM-R44P

Sensor

3.2
0.126

3.2
0.126

13.7
0.539

13.2
0.520
6.4
0.252
7
0.276

2.9
0.114
9
0.354

7
13.6
0.535 0.276
3.3 0.130
4 0.157

2-3.5 0.138 mounting holes


2.7 0.106 cable, 1 m 3.281 ft long

7
13.6
0.276 0.535
3.3 0.130
4 0.157
2-3.5 0.138
mounting holes

FA
COMPONENTS
MACHINE
VISION
SYSTEMS

Selection
Guide

Beam axis

13.4 0.528
5
2.9
0.197
0.114

10.8
0.425

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

6.4
0.252

3.3
0.130

Sensor

13.7
0.539

Beam axis

HUMAN
MACHINE
INTERFACES

Beam axis
12.6
0.496

Beam axis

7
0.276

PLC /
TERMINALS

2.9 0.114

2-3.2 0.126 mounting holes

PM-F44PM-F44P

2.5
0.098

LASER
MARKERS

2.7 0.106 cable, 1 m 3.281 ft long

8.5
15.5 0.335
0.610

MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES

Operation indicator
(Vermilion)
13.4 0.528
5
0.197

SIMPLE
WIRE-SAVING
UNITS

2-3.5 0.138 mounting holes

15
0.591

10.8
0.425

SENSOR
OPTIONS

WIRE-SAVING
SYSTEMS

7 0.276
Beam axis

2
0.079 4.8
0.189

6.4
0.252
Beam axis

8.5 0.335
15.5 9 0.354
0.610

2.7 0.106 cable,


1 m 3.281 ft long

Sensor

2.7 0.106 cable, 1 m 3.281 ft long

13.4 0.528
5
0.197

Operation indicator
(Vermilion)

PM-Y44PM-Y44P

4-R2

INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS

2
2-mounting 0.079 4.8
0.189
oblong holes

19
0.748

PM-L44PM-L44P

PRESSURE /
FLOW
SENSORS

Beam axis

26.2
1.031
10.8
0.425

10.3
0.406

AREA
SENSORS
LIGHT
CURTAINS

8.5 0.335

13
0.512

6.2
0.244

2-3.8 0.150
mounting holes

4
2 0.157
0.079

Beam axis

13.4 0.528
5
0.197
2.9 0.114
1
0.039

26
1.024

LASER
SENSORS

MICRO
PHOTOELECTRIC
SENSORS

7 0.276
3 0.118

Beam axis

19 0.748
13.4 0.528
5
0.197

FIBER
SENSORS

PHOTOELECTRIC
SENSORS

13.7
0.539

3.5 0.138

7
0.276

464

The CAD data in the dimensions can be downloaded from our website.

PM-K44PM-K44P
25.4 1.000
19 0.748

PM-44 SERIES PM-54 SERIES

U-shaped

7
0.276
13.4 0.528
5
0.197

8.5
0.335

2.5
0.098

PM-64
1
0.039
Beam axis

26.2
1.031
10.8
0.425
2
0.079

4.8
0.189
Operation indicator
(Vermilion)

Convergent
Reflective

2.7 0.106 cable,


1 m 3.281 ft long

PM-24
PM-44/
PM-54

465
FIBER
SENSORS
LASER
SENSORS

Small U-shaped Micro Photoelectric Sensor

PM-44 SERIES PM-54 SERIES

DIMENSIONS (Unit: mm in)

The CAD data in the dimensions can be downloaded from our website.

PM-K54PM-K54P

PHOTOELECTRIC
SENSORS

Sensor

25.4 1.000
19 0.748

MICRO
PHOTOELECTRIC
SENSORS

13.7 0.539
7 0.276

Beam axis
2-3.2 0.126 mounting holes

LIGHT
CURTAINS

19 0.748
13.4 0.528
5 0.197
1 0.039

PRESSURE /
FLOW
SENSORS

2.9 0.114

6.4
0.252

6.4
0.252

13.8
0.543

22.2
0.874

11
0.433 6.8
0.268

PARTICULAR
USE
SENSORS

Operation indicator
(Vermilion)

Beam axis

8.5
0.335

INDUCTIVE
PROXIMITY
SENSORS

5 0.197
2-3.8 0.150 mounting holes

LASER
MARKERS
PLC /
TERMINALS

6.3
0.248

2.5
0.098

PM-L54PM-L54P

Sensor

26 1.024
19 0.748
3.2
0.126 1 0.039
7
0.276
14.5
0.571 6.8
0.268

Beam axis

22.2
0.874
6.8
0.268

Operation indicator
(Vermilion)

13.4
0.528

MACHINE
VISION
SYSTEMS

7 0.276
Beam axis
11
0.433

21.5
0.846
6.8
0.268

Operation indicator
(Vermilion)
13.4
0.528
5
0.197

6.4
0.252
Beam axis
7.2
0.283

UV
CURING
SYSTEMS

6.4
0.252

2.9
0.114
Beam axis

8.5
15.5 0.335
0.610

6.5
0.256

12.6
0.496

3.3
0.130
2-3.2 0.126 mounting holes

PM-F54PM-F54P
Selection
Guide

3.5 0.138

5 0.197

19
0.748

3.6
0.142

Sensor
2-3.5 0.138 mounting holes

7
1 0.276
0.039

Operation indicator
(Vermilion)

13.4 0.528
5
0.197

8.5 0.335
15.5 9 0.354
0.610

FA
COMPONENTS

PM-Y54PM-Y54P

4-R2 R0.079

2-mounting oblong holes

2.9
0.114

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

2-mounting oblong holes

Beam axis

5
0.197

HUMAN
MACHINE
INTERFACES

19
0.748

2.9
0.114

8.5 0.335

5 0.197

STATIC
CONTROL
DEVICES
ENDOSCOPE

13
0.512

3
0.118

Beam axis

13.4 0.528
5
0.197

1
0.039

6.2
0.244

SIMPLE
WIRE-SAVING
UNITS

MEASUREMENT
SENSORS

26
1.024

4.3
0.169
3.2
0.126

5.5 0.217

SENSOR
OPTIONS

WIRE-SAVING
SYSTEMS

Sensor

3.5
0.138

7
0.276

AREA
SENSORS

PM-T54PM-T54P

2.5
0.098

6.5
0.256
3.3
0.130

Sensor

PM-R54PM-R54P

Sensor

Beam axis

Beam axis

U-shaped
Convergent
Reflective

2.5
0.098

PM-64
PM-24
PM-44/
PM-54

1
0.039

7
0.276
13.7
0.539
13.4
0.528
5
0.197

7
0.276
13.7
0.539
13.2
0.520
6.4
0.252
7
0.276

2.9
0.114
Beam axis 8.5
0.335
22.2
0.874
6.8
0.268
5 0.197
Operation indicator
(Vermilion)

3.2
0.126

9
0.354
7
13.6
0.535 0.276
3.3 0.130

3.2
0.126

13.2 0.520
6.4
0.252
7
0.276

7
13.6
0.276 0.535
3.3 0.130

8.5
0.335

Beam axis

22.2
0.874
6.8
0.268
5 0.197

2-3.5 0.138 mounting holes


2-3.5 0.138 mounting holes

13.4 0.528
5
0.197
1
0.039

2.9
0.114
9
0.354

2.5
0.098

Operation indicator
(Vermilion)

Small U-shaped Micro Photoelectric Sensor

DIMENSIONS (Unit: mm in)

466

PM-44 SERIES PM-54 SERIES

The CAD data in the dimensions can be downloaded from our website.

* Terminal part (PM-54, PM-54P)

CN-14

Connector (Optional)

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS

+V

1
0.039

1
0.039
1.3
0.051

MICRO
PHOTOELECTRIC
SENSORS

0V

0.8
0.031
1.6
0.063

2.1
0.083
2.54 2.54 2.54
0.100 0.100 0.100

t 0.3
t 0.012

7.5
0.295

1
0.039
+V

AREA
SENSORS

4.6
0.181

13
0.512

1
1
0.039 0.039

0V

(5)
(0.197)

LIGHT
CURTAINS
0V

+V

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

t 0.4 t 0.016
0.8 0.031
2 0.079
1.6 0.063
6
0.236
(2.54) (0.100)

PARTICULAR
USE
SENSORS

(7.62)
(0.300)

SENSOR
OPTIONS

CN-14HCN-14H-2

Hook-up connector (Optional)

CN-14H-C1CN-14H-C3 Connector attached cable (Optional)

SIMPLE
WIRE-SAVING
UNITS

WIRE-SAVING
SYSTEMS

(50)
(1.969)

2
1

6
0.236
15
0.591

+V

6
0.236

MEASUREMENT
SENSORS

ENDOSCOPE

0V

0V

+V

(8)
(0.315)

STATIC
CONTROL
DEVICES

+V

13
0.512

13
0.512

0V

15
0.591

0V

+V

LASER
MARKERS

3.8 0.150 cable

PLC /
TERMINALS

Length L
Model No.

Length L

CN-14H-C1

1 m 3.281 ft

CN-14H-C3

3 m 9.843 ft

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide
U-shaped
Convergent
Reflective

PM-64
PM-24
PM-44/
PM-54

You might also like