Professional Documents
Culture Documents
Single point
Single point mapping
Linear array mapping
2-D Focal Plane Array (FPA) imaging
4: FPA Imaging
With an FPA detector, up to
16384 spectra can be recorded
simultaneously in a single
measurement.
Biomedical/Biological Research
Forensics
Car paint layer & structure analysis
Trace evidence analysis
Pharmaceuticals
Ingredient distribution
Coating analysis
Defect/particle analysis
Electronics
Defect analysis
Art Conservation
Painting components & layer identification
Geology
Study of inclusions
Food/Cosmetics
Study of emulsions, eg cheese, mayonnaise,
cream
A New Method of
Magnification Enhancement
Stage
Stage
Its the total magnification that matters, which together with the native FPA pixel size,
equates to final pixel size at the sample plane.
Objective magnification alone, is only a factor in the overall total magnification equation
A big advantage of this approach is FULL PRESERVATION of the long objective working
distance of 21mm, allowing a wide array of accessories and sample holders to be used
Stage
4x
0.2 NA
Pixel size:
Pixel size:
5.5 mm (normal)
3.3 mm (normal)
0.66 mm (high mag) 1.1 mm (high mag)
74x
0.65 NA
Pixel size:
0.5 mm
36x
0.5 NA
Pixel size:
1.1 mm
15x
0.4 NA
24 mm
15x
0.62 NA
10 mm
25x
0.81 NA
1 mm
Agilent
38 mm
NEW
21 mm
12 mm
Pixel size:
2.7 mm
Pixel size:
19 mm (normal)
3.8 mm (high mag)
Objective comparisons
Achieved
Spatial
Resolution
3750 cm-1
Achieved
Spatial
Resolution
2500 cm-1
4.3 um
5.0 um
420x420 um
1.4 um
1.7 um
85x85 um
6.9 um
7.6 um
700x700 um
2.4 um
3.0 um
140x140 um
20.4 um
20.0 um
2400x2400 um
0.98um
1.4um
Superior signal-to-noise
- What is a synchrotron?
-
Great source of narrow intense beam of light (eg IR), which are great
for single point microscopy with apertures <10 microns.
Synchrotrons are great for very small FOVs (<10um), but to image
large FOVs (>hundreds of microns), requires multiple beam extractions
and/or defocusing to spread the light out, removing all the brightness
advantages of a synchrotron
For large area imaging, simple optics rules tell us that a large area
source is required to illuminate a large area detector, such as an FPA
For this, the traditional FTIR globar is still the best option, as the large
area globar is matched to the large area FPA detectors.
10 um synchrotron
source
Transfer optics
(spectrometer & microscope)
1:1
In single point mode, beam does not need to illuminate full area of MCT detector.
High brilliance of synchrotron beam is utilised
FPA (128x128)
Transfer optics
(spectrometer & microscope)
5.1 mm
10 um synchrotron
source
1:260000
5.1 mm
In imaging mode, beam must illuminate full area of FPA detector, this therefore
requires a 260,000x defocussing, losing the synchrotron intensity advantage
FPA (128x128)
5.1 mm
Transfer optics
(spectrometer & microscope)
5 mm
1:1
5.1 mm
7.5 mm
With a globar (image doubled with retroreflector), the hot spot is area is a 1:1 match
to the FPA area, maximising intensity usage, resulting in better sensitivity
Largest Field
of View
Proprietary 4x IR
objective
Measure cm x cm
areas in minutes
Fastest
analysis time
Live FPA
imaging
Enhanced chemical
contrast software mode
Eliminate sample prep
Avoid damaging samples
Unparalleled IR energy from the FTIR bench (>400%) coupled with increased IR
throughput of new 15x objective (>40%) guarantees the highest quality data in the
shortest period of time.
Faster than any other FPA, Linear Array or single point detector available today
Measure the largest samples at the highest resolution in the shortest period of
time!
Step 3.
Step 2.
Step 4.
IR light out
IR light in
micro ATR
IR light in
micro ATR
Sample
100 micron
wide (thick)
micro-vice
Microscope Stage
STEP 5.
raise stage
to make
contact &
collect data
Sample
100 micron
wide (thick)
micro-vice
Microscope Stage
No Pressure
(before contact)
No Pressure
(before contact)
Stage is
raised
No Pressure
(before contact)
First Contact
No Pressure
(before contact)
First Contact
Stage is
raised
No Pressure
(before contact)
First Contact
Increasing Pressure
No Pressure
(before contact)
First Contact
Increasing Pressure
Complete Contact
Stage is
raised
No Pressure
(before contact)
First Contact
Increasing Pressure
No Pressure
(before contact)
First Contact
Increasing Pressure
Complete Contact
Stage is
raised
No Pressure
(before contact)
First Contact
Increasing Pressure
No Pressure
(before contact)
First Contact
Increasing Pressure
Complete Contact
Stage is
raised
No Pressure
(before contact)
First Contact
Increasing Pressure
No Pressure
(before contact)
First Contact
Increasing Pressure
Complete Contact
Stage is
raised
No Pressure
(before contact)
First Contact
Increasing Pressure
No Pressure
(before contact)
First Contact
Increasing Pressure
Complete Contact
Micro ATR
Easy to clean
Sample Presentation
500 um
ATR
ATR
spot
3
spot 1
ATR
spot 2
670 um
Collection Conditions:
Resolution:
Scans (time):
Spectral Range:
Collection Mode:
Pixel Size & FOV:
4 cm-1
32 scans (~30 sec) per spot
4000 850 cm-1
Micro ATR & transmission (5 micron microtomed slices)
1.1 microns/pixel, 70x70 microns
5. Transmission with NEW 25x HIGH mag (0.66 um pixel size & 85x85 um FOV)
Absorbance
0.10
Layer 1&3
70 um
70 um
Absorbance
0.15
0.05
0.00
3000
2000
Wavenumber
ATR Chemical
RGBY Composite Image
3 4
70 um
0.04
70 um
Polycarboxylic acid ester
polymer (possibly)
Layer 4
~5 um thick
Red: PE
Yellow: PE (with additive)
Green: Polycarboxylic acid ester (possible)
Blue: Polyamide
70 um
70 um
Absorbance
0.06
0.02
0.00
70 um
70 um
0.05
0.00
1000
Absorbance
70 um
0.10
polyamide
Layer 5
0.10
0.05
0.00
70 um
Image @
2850 cm-1
70 um
Absorbance
Layer 3, 7
0.10
& 11
PE (with additives)
~6 um thick (centre layer)
0.05
70 um
70 um
8 10
7 9 11
Layer 4
0.02
Absorbance
0.00
3500 3000 2500 2000 1500 1000
Wavenumber
0.15
Polyamide
~7um (left)
~2um (centre)
~3um (right)
Layer 5, 8 & 10
0.10
0.05
0.00
0.08
0.06
0.04
0.02
0.00
Layer 6
3500
0.06
Absorbance
Image @
1090 cm-1
Image @
2951 cm-1
0.04
Absorbance
Image @
1202 cm-1
Image @
1725 cm-1
0.06
Red: PE
Green: Polycarboxylic acid
polymer (possibly)
Blue: Polyamide
White: Polypropylene
Cyan: EVOH
Absorbance
0.00
0.04
Polypropylene
~20um
1500 1000
EVOH
~5um
(spectral overlap from
Polyamide present)
Layer 9
0.02
0.00
3500
3000
2500 2000
Wavenumber
1500
1000
May 20, 2015
Confidentiality Label
46
70 um
70 um
Absorbance
0.15
PP (possible with an
additive as evident by
peak at 1060cm-1)
~37 um thick
Layer 11
0.10
0.05
0.00
3500
70 um
Absorbance
70 um
Red: PE
Blue: Polyamide
Cyan: EVOH
0.15
Layer 5, 8 & 10
0.10
1500
Polyamide
~2um (left)
~3um (right)
0.05
0.00
3500
1500
11
Absorbance
0.06
8 10
79
1000
1000
EVOH
~5um thick
(spectral overlap
from Polyamide
present)
Layer 9
0.04
0.02
0.00
3500
3000
2500
2000
Wavenumber
1500
1000
The sample was measured across its entire width with three
slightly overlapping ATR measurements, with a total
collection time of ~ 1.5 mins.
140 um
180 um
PA
~20
~6
~5
~37
PE
PE
~5 ~7
PE
PA
EVOH
PA
PE
with additive
~11
PP
~24
PE
~3 ~3
~11
7 8 9 10
11
Pixel size:
Obj mag:
FOV:
Total system mag:
1.1micron
15x, 0.62NA
70x70um
36x
~130 um
140 um
2
3
EVOH, layer 3
Absorbance
180 um
PA, layer 2
PE, layer 1
3500
3000
2500
2000
Wavenumber
1500
1000
Pixel size:
Obj mag:
High mag:
FOV:
Total system mag:
Working distance:
0.66 micron
25x, 0.81NA
ON
85x85um
61x
12mm
May 20, 2015
Confidentiality Label
49
140 um
EVOH, layer 3
Absorbance
3
PA, layer 2
180 um
PE layer 1
3500
3000
2500
2000
Wavenumber
1500
1000
Pixel size:
Obj mag:
High mag:
FOV:
Total system mag:
Working distance:
1.1micron
15x, 0.62NA
ON
140x140um
36x
21mm
May 20, 2015
Confidentiality Label
50
140 um
180 um
Pixel size:
Obj mag:
High mag:
FOV:
Total system mag:
3.3micron
25x, 0.81NA
OFF
420x420um
12x
May 20, 2015
Confidentiality Label
51
140 um
180 um
Pixel size:
Obj mag:
High mag:
FOV:
Total system mag:
5.5 micron
5x, 0.62NA
OFF
700x700 um
7.3x
May 20, 2015
Confidentiality Label
52
0.25
1 scan
- Typical S:N
improvement of
~5-10x
Absorbance
0.20
0.15
0.10
0.05
128 scans
0.00
- Corresponding time
saving (for equivalent
S:N) is 25-100x !
3200 3000 2800 2600 2400 2200 2000 1800 1600 1400 1200 1000
Wavenumber
Absorbance
0.01
0.00
-0.01
Residual spectrum
3200
3000
2800
2600
2400
2200
2000
Wavenumber
1800
1600
1400
1200
1000
Agilent Confidential
May 20, 2015
53
70 mm
ATR
0.10
0.05
0.00
3500
3000
2500
2000
Wavenumber
1500
1000
70 mm
0.06
640 um
0.04
Absorbance
480 um
0.15
0.02
0.00
GREEN DEFECT
RED - POLYMER
3500
3000
2500
2000
Wavenumber
1500
1000
IR image
Absorbance
Image created
at 2848 cm-1
ATR
0.10
PE
0.05
0.00
3500
10 um
3000
2500
2000
Wavenumber
1500
1000
0.10
640 um
Polyamide
Absorbance
Image created
at 1644 cm-1
0.08
70 mm
0.06
0.04
0.02
0.00
-0.02
3500
70mm
3000
0.18
2500
2000
Wavenumber
1500
1000
0.16
0.14
0.12
Absorbance
480 um
0.15
0.10
0.08
0.06
3000
2500
Wavenumber
2000
1500
1000
1118 cm-1
(3.4 microns)
(6.9 microns)
(8.9 microns)
85 mm
2915 cm-1
85mm
Pixel size:
Obj mag:
High mag:
FOV:
Total system mag:
Working Distance:
0.66 micron
25x, 0.81 NA
ON
85x85 um
61x
12 mm
Agilent Confidential
May 20, 2015
56
57
Absorbance
70 mm
480 mm
0.20
Row = 29 Col = 19
0.15
Active
0.10
0.05
640 mm
0.4
70 mm
3500
3000
Row = 12 Col = 10
Absorbance
0.3
2500
2000
Wavenumber
1500
1000
Lactose
0.2
0.1
0.0
3500
Absorbance
0.3
3000
2500
2000
Wavenumber
1500
1000
Row = 43 Col = 59
Starch
0.2
0.1
0.0
3500
Defect
Absorbance
(next slide)
0.3
3000
2500
2000
Wavenumber
1500
1000
Row = 51 Col = 28
Cellulose
0.2
0.1
0.0
3500
3000
2500
2000
Wavenumber
1500
1000
Absorbance
70 mm
480 mm
0.20
Row = 10 Col = 26
Polyester
0.15
0.10
0.05
3500
70 mm
0.15
Absorbance
640 mm
3000
2500
2000
Wavenumber
1500
Row = 30 Col = 28
Polyamide
0.10
0.05
3500
3000
2500
2000
Wavenumber
1500
Contaminant Composite
(RG), part 2
70 mm
70 mm
1000
1000
70 um
350 um
5 mm
70 um
Absorbance
0.03
0.02
0.01
0.00
3500
3000
2500
Wavenumber
2000
1500
1000
480 um
70 microns
Visible Image
640 um
IR image
at 1647cm-1
Absorbance
0.3
Row = 6 Col = 30
1647.960 12.936
0.2
0.1
0.0
3800
3600
3400
3200
3000
2800
2000
1800
1600
1400
1200
1000
Absorbance
0.20
0.15
70 um
350 um
Visible Image
70 um
0.10
0.05
0.00
3500
3000
2500
Wavenumber
2000
1500
1000