You are on page 1of 11

M2-iLAN-2

Laser Scanner

Due to the modular construction system nearly all Scanner models can be
used on different ambient conditions:

Many fields of application due to


modular construction
Integrated controller
LAN connection
Low current consumption

Standard Model
Basic module for the use in dust-free environments at temperatures up to
40 C
Model -S with Protective Window
Basic module with protective window for the use in dusty environments
Model -WS with Protective Window and Cooling
Basic module with protective window and cooling element for the use in
dusty environments at high temperatures
Please specify the desired model when ordering!

DB-M2iLAN-2_6-01-E

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

Specifications M2iLAN-2
M2-iLAN-2
Measuring Range Z [mm]
Begin of Measuring Range Z [mm]
Begin of Scan Range X [mm]
End of Scan Range X [mm]

6/4

10/13

20/10

40/20

60/30

80/40

10

20

40

60

80

120/60 260/100
120

260

400/200
400

38.6

65

55

50

53

63

84

150

330

13

10

20

30

40

60

100

200

4,5

15

13

26

40

55

80

170

280

Resolution Z * [mm]

0.003

0.01

0.02

0.02

0.035

0.045

0.06

0.13

0.2

Resolution X * [mm]

0.008

0.025

0.02

0.04

0.07

0.09

0.14

0.29

0.48

Linearity 0.2 % of Measuring Range


Laser Protection Class 2M; optionally: enhanced laser power
Measuring Rate 100 Hz
Specials feeler gage, elapsed hour counter, serial number and sensor data readable
Light Source Laser, wave length 658 nm, red visible
Ambient Light 5,000 Lux
Operating Time Laser-Diode: 50,000 h
Max. Vibration 5 g up to 1 kHz
Operating Temperature 0 C ... +40 C
Storage Temperature -20 C ... +70 C
Humidity < 90% RH
Protection Class IP 64
Power Supply 8 - 30 V, Pw = 15 W
Measuring Surface white to black, shiny, high mirroring
* Measurement on matt white, diffusely reflecting surface

Pin Assignment:
Ethernet cable - connector M12, round, 4 pin, D-coded, female:

Control cable - connector M12, round, 8 pin, A-coded, male:

Pin

Signal

Comment

Pin

Signal

Tx+

Transmission Data Ethernet +

8 - 30 V

Rx+

Received Data Ethernet +

Input 1

Tx-

Transmission Data Ethernet -

GND

Rx-

Received Data Ethernet -

Input 2

Connected with connector housing

Sync out

Sync in

TxD

RS232 Diagnostic Interface

Laser out

Minimum voltage 5 V

Shield

Comment

Incremental Encoder A + B

for Synchronization of Sensors

Shield

Scope of Delivery

Options

Accessories

Scanner head without cable and power


supply (please order separately)
Demo Software
Manual

Option -S (with protective window)


Option -WS (with protective window and
cooling element)
2 Scanners synchronized

Connection cable (different lengths and


types)
Ethernet cable (different lengths and types)
Protective window (different types)
Power supply

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

please state for ordering

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

not included in delivery

Laser Scanner M2-iLAN-2-6/4

88

60

34

12.2

holes 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep
36
18

38.6
Range begin

Power
Conrol

0
5

Ethernet

15

contact areas

70
10

40.02

6.5
96

6.09

114.7

0
Z
4095

4095 X 0
4.5

1.06
18

15.96

Weight 390 g

Order Number

Product Name

i530007

M2-iLAN-2-6/4

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

6
Range

108.7

135
140

89.8

68.8

36.4

Laser Scanner M2iLAN-2-10/13


40
20
122
107
Power
Conrol

Ethernet

1
Weight 750 g

contact areas

68.4
holes 4.2 end-to-end
with thread M5 on both sides
approx. 12 mm deep

13

18
13
0

32.8

65
Range begin

20

23.5

13
0
Z
4095

Z
X
15

0
10
Range

4095

78

96

3
2

connections for
air- or water-cooling
inner=4; outer=6

40

55
15

cooling unit

Ethernet

Power
Conrol

124

10
7.8
protective window

0
5

Weight 825 g

Weight 1050 g

Order Number

Product Name

Description

i530010

M2-iLAN-2-10/13

Standard Model (1)

i531010

Option -S

Protective Window (2)

i533010

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

Laser Scanner M2-iLAN-2-20/10

36

84

60

34.2

19

12.2

holes 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep
18

80

Power
Conrol

Ethernet

65
60

Weight 330 g

contact areas
5
0

55
Range begin

6.5
17
18
10
0
Z

Z
X

4095

0
20
Range

4095

13

40

22

connections for
air- or water-cooling
inner =4; outer =6

3
51

39
3

15

cooling unit

Power
Conrol

Ethernet

82

0
4.9

protective window
23

Weight 380 g

Weight 530 g

Order Number

Product Name

Description

i530020

M2-iLAN-2-20/10

Standard Model (1)

i531020

Option -S

Protective Window (2)

i533020

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

Laser Scanner M2-iLAN-2-40/20

36

95

60

19

holes 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep
18
80

Ethernet

Power
Conrol

65
60

Weight 360 g

contact areas
5
0
50
Range begin

6.5
19
18
20

40
Range

4095

40

22

4095

connections for
air- or water-cooling
inner =4; outer =6

26
X

2
39
3

51
15

cooling unit

Ethernet

Power
Conrol

82

0
4.9
protective window
23

Weight 420 g

Weight 580 g

Order Number

Product Name

Description

i530040

M2-iLAN-2-40/20

Standard Model (1)

i531040

Option -S

Protective Window (2)

i533040

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

Laser Scanner M2-iLAN-2-60/30

95

60

19

holes 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep
18

1
Weight 360 g

53
Range begin

Ethernet

Power
Conrol

65
60

contact areas
5
0
6.5
19
18
30

60
Range

4095

4095

40

22

40

2
connections for
air- or water-cooling
Inner =4; outer =6

39
3

51
15

cooling unit

82

Ethernet

Power
Conrol

4 .4

0
4.9
protective window
23

Weight 420 g

Weight 580 g

Order Number

Product Name

Description

i530060

M2-iLAN-2-60/30

Standard Model (1)

i531060

Option -S

Protective Window (2)

i533060

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

60

134

holes 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep

34.2

13.2
19

Laser Scanner M2-iLAN-2-80/40

36
18

80
65
Power
Conrol

Ethernet

1
Weight 460 g

contact areas

5
0

63
Range begin

6.5
21
18

40

80
Range

X
4095

4095

connections for
air- or water-cooling
inner =4; outer =6

40

22

55

3
51

39
3

15

cooling unit

82

0
4.9
protective window
25

Weight 530 g

Weight 750 g

Order Number

Product Name

Description

i530080

M2-iLAN-2-80/40

Standard Model (1)

i531080

Option -S

Protective Window (2)

i533080

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

Laser Scanner M2-iLAN-2-120/60

186

173.5

60

35.7

13.7
19

holes 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep
36
18
80

Ethernet

Power
Control

65
60

contact areas

Weight 540 g

32.5

5
0
6.5
84
Range begin

18.6
18

60

120
Range

4095

4095

40

22

X
80

connections for
air- or water-cooling
inner =4; outer =6
3

84.80

0
5.2

3
51

39
15

cooling unit

protective window

20

Weight 630 g

Weight 890 g

Order Number

Product Name

Description

i530120

M2-iLAN-2-120/60

Standard Model (1)

i531120

Option -S

Protective Window (2)

i533120

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

44
270
275

0
5

100

126.5

holes 4.2 end-to-end


with thread M5 on both sides
approx. 10 mm deep

148.5

Laser Scanner M2-iLAN-2-260/100

18

74.8

Ethernet

Power
Conrol

60
55

Weight 900 g

5
0
18

6.5
22

150
Range begin

contact areas

100

260
Range

4095

4095

270
275

connections for
air- or water-cooling
inner =4; outer =6

113

95
100

170

44

3
15

18

79.8

44
cooling unit

60
55

5
0
5.2
20.9

protective window

Weight 920 g

Order Number

Product Name

Description

i530260

M2-iLAN-2-260/100

Standard Model (1)

i531260

Option -S

Protective Window (2)

i533260

Option -WS

Protective Window and Cooling Element (3)

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

Weight 1460 g

Laser Scanner M2-iLAN-2-400/200

60.0
19.0

50.0
25.0
34.0

60.0

Ethernet

Power etc.

hatched areas
are contact areas

Range begin
330.0

hole 4.2 end-to-end


with thread M5 on both sides
approx. 12 mm deep

146.9

5.0

590.0
482.2
461.1
402.0

Range
400.0

4095

4095

Weight 2000 g

Order Number

Product Name

i530400

M2-iLAN-2-400/200

Error and technical modification reserved

Breslauer Strae 2
D-85386 Eching
www.MELsensor.de

DB-M2iLAN-2_6-01-E

E-Mail: info@MELsensor.de
Tel.
+49 (0) 89 / 327 150-0
Fax
+49 (0) 89 / 319 20 23

You might also like