You are on page 1of 6

KHARAFI NATIONAL

CIVIL MATERIAL TESTING LABORATORY


LAB REPORT FOR PROCTOR COMPACTION TEST
Name of Project:

Sulaibiya WasteWater Treatment Plant Extension Work

Sample Descriptions:

Backfilling Sample

Location of Sample:

Ardiya stock file soil

Sample Tested by:

Sri Rama Murthy

Test Report No:

Test Report Date:

10

31.10.15

Applicable / Reference Standards:


Test Date

31.10.15

ASTM D 1557

Lab Findings / Readings


Trails

Weight of mold & bass (W1) in g

3417

3417

3417

3417

3417

Weight of mold + base + wet soil (W2) in g

5198

5351

5431

5423

5312

Volume of the Proctor mold (V) in Cm3

940

940

940

940

940

Dry density = (W2-W1)/V in g/Cm3

1.89

2.06

2.14

2.13

2.02

Sample Container / Can' Number

Weight of empty Container/Can (W3) in grams

64

58.5

61

58

55.5

Weight of Container + wet soil (W4) in grams

115

117

113

114

127

Weight of Container + dry soil (W5) in grams

112

112.5

108

107.8

118

% of Moisture(%w) = (W4-W5)x100/(W5-W3)

6.3

8.3

10.6

12.4

14.4

d = /(1+w/100) in g/Cm

1.78

1.90

1.94

1.90

1.76

Dry density

2.00
1.95

1.94

MDD gm/cc

1.90

1.90

1.90

1.85
1.80

1.78

1.76

1.75

Row 22

1.70
1.65
1.60
6.3

8.3

10.6
OMC %

12.4

Calibration Details:

14.4

Modified protor Validity : 20-02-16

Maximum Dry density in Kg/Cm3


Optimum Moisture Content (OMC)

Lab Remarks

1695-30/ TWI 125 Att. 6 Rev .0 13 Aug. 2013

Page 1 of 1

KHARAFI NATIONAL

Name

1695-30/ TWI 125 Att. 6 Rev .0 13 Aug. 2013

Designation

Signature

Date & Seal

Page 1 of 1

KHARAFI NATIONAL

CIVIL MATERIAL TESTING LABORATORY


LAB REPORT FOR PROCTOR COMPACTION TEST
Name of Project:

Sulaibiya WasteWater Treatment Plant Extension Work

Sample Descriptions:

Backfilling Sample

Location of Sample:

Ardiya stock file soil

Sample Tested by:

Sri Rama Murthy

Test Report No:

Test Report Date:

26.10.15

Applicable / Reference Standards:


Test Date

26.10.15

ASTM D 1557

Lab Findings / Readings


Trails

Weight of mold & bass (W1) in g

3417

3417

3417

3417

3417

Weight of mold + base + wet soil (W2) in g

5120

5306

5421

5418

5288

Volume of the Proctor mold (V) in Cm3

940

940

940

940

940

Dry density = (W2-W1)/V in g/Cm3

1.81

2.01

2.13

2.13

1.99

Sample Container / Can' Number

Weight of empty Container/Can (W3) in grams

64

58.5

61

58

55.5

Weight of Container + wet soil (W4) in grams

115

117

113

114

127

Weight of Container + dry soil (W5) in grams

112

112.5

108

107.8

118

% of Moisture(%w) = (W4-W5)x100/(W5-W3)

6.3

8.3

10.6

12.4

14.4

d = /(1+w/100) in g/Cm

1.71

1.85

1.93

1.89

1.74

Dry density

1.95

1.93

1.90

1.89
1.85

MDD gm/cc

1.85
1.80
1.75
1.70

1.74

Row 22

1.71

1.65
1.60
6.3

8.3

Maximum Dry density in Kg/Cm3


Optimum Moisture Content (OMC)

10.6
OMC %

1.930

12.4

Calibration Details:

14.4

Modified protor Validity : 20-02-16

11.00

Lab Remarks

1695-30/ TWI 125 Att. 6 Rev .0 13 Aug. 2013

Page 1 of 1

KHARAFI NATIONAL

Name

1695-30/ TWI 125 Att. 6 Rev .0 13 Aug. 2013

Designation

Signature

Date & Seal

Page 1 of 1

KHARAFI NATIONAL

CIVIL MATERIAL TESTING LABORATORY


LAB REPORT FOR PROCTOR COMPACTION TEST
Name of Project:

Sulaibiya WasteWater Treatment Plant Extension Work

Sample Descriptions:

Backfilling sample

Location of Sample:

Supplier - 1

Sample Tested by:

Sri Rama Murthy

Test Report No:

Test Report Date:

10/31/2015

Applicable / Reference Standards:


Test Date

26.10.15

ASTM D 1557

Lab Findings / Readings


Trails

Weight of mold & bass (W1) in g

3417

3400

3332

3423

3356

3420

Weight of mold + base + wet soil (W2) in g

5022

5155

5214

5372

5284

5200

Volume of the Proctor mold (V) in Cm3

940

940

940

940

940

940

Wet density = (W2-W1)/V in g/Cm3

1.71

1.87

2.00

2.07

2.05

1.89

Sample Container / Can' Number

Weight of empty Container/Can (W3) in grams

64

58

61

58

55

56

Weight of Container + wet soil (W4) in grams

153

154

155

151

152

152

Weight of Container + dry soil (W5) in grams

148

146.5

146.2

141

140

138.5

% of Moisture(%w) = (W4-W5)x100/(W5-W3)

6.0

8.5

10.3

12.0

14.1

16.4

1.612

1.721

1.815

1.850

1.797

1.627

Dry density

d = /(1+w/100) in g/Cm

1.900
1.850
1.800
1.750
1.700
1.650
1.600
6.0

8.5

10.3

12.0

14.1
Calibration Details:

Maximum Dry density in Kg/Cm

Optimum Moisture Content (OMC)

16.4
Modified protor Validity : 20-02-16

1.851
12.00

Lab Remarks

1695-30/ TWI 125 Att. 6 Rev .0 13 Aug. 2013

Page 1 of 1

KHARAFI NATIONAL

Name

1695-30/ TWI 125 Att. 6 Rev .0 13 Aug. 2013

Designation

Signature

Date & Seal

Page 1 of 1

You might also like