Professional Documents
Culture Documents
TECHNOLOGY
SERVICES
Confidential Report
Our Ref: 30/06414/2
Notified Body
for PPE Directive,
Construction Products Directive
& Marine Equipment Directive
I.D. No. 0338 & 0339
1066
FIRE
TECHNOLOGY
SERVICES
7 November 2012
Page 1 of 3
Our Ref:
30/06414/2
Client:
Westex Inc.
2845 W. 48th Place
Chicago
Illinois 60632
USA
Job Title:
Date of Receipt:
14 September 2012
Description of Sample:
Work Requested:
This is a summary report detailing the results as required by the EN ISO 11611: 2007 performance standard.
Test methods marked * in results tables are not UKAS accredited.
1066
FIRE
TECHNOLOGY
SERVICES
7 November 2012
Page 2 of 3
Sample:
Performance Standard:
Cleansing Pretreatment:
Summary of Results:
PROPERTY
TEST METHOD
EN ISO 11611
REQUIREMENTS
Class 1: 400N
Class 2: 400N
Class 1: 20N
Class 2: 20N
RESULTS
OBTAINED
Warp
Weft
921N
811N
Across Warp Across Weft
27.4N
28.9N
Warp
-2.6%
6.1 Tensile
strength
6.2 Tear
strength
6.5 Dimensional
change
Woven fabrics:
Class 1: 3%
Class 2: 3%
Weft
-1.0%
No flaming to edge
No hole formation
No flaming or molten
debris
No afterflame
No afterglow
PASS/FAIL
PASS
Class 1 and 2
PASS
Class 1 and 2
PASS
Class 1 and 2
PASS A1
Class 1 and 2
1066
FIRE
TECHNOLOGY
SERVICES
7 November 2012
Page 3 of 3
Sample:
TEST METHOD
EN ISO 11611
REQUIREMENTS
Class 1 and Class 2:
No flaming to edge
No flaming or molten
debris
Mean afterflame 2s
Mean afterglow 2s
RESULTS
OBTAINED
6.8 Impact of
spatter
No ignition
Class 1: 15 drops
Class 2: 25 drops
No ignition
22 drops
Class 1: RHTI24 7s
Class 2: RHTI24 16s
RHTI24 = 15.1s
6.10 Electrical
resistance
EN 1149-2: 1997*
at 85 5% r.h.
3.5 x 105
6.11.2 pH-value
pH = 7.3
No flaming to edge
No flaming or molten
debris
No afterflame
No afterglow
PASS/FAIL
PASS A2
Class 1 and 2
PASS
Class 1
PASS
Class 1
PASS
Class 1 and 2
PASS
Class 1 and 2
An estimation of uncertainty of measurement has not been taken into account when making a judgement to any pass/fail criteria.