Professional Documents
Culture Documents
SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this timer.
MULTI-FUNCTION
ANALOGUE TIMER
User's Manual
WARNING
CAUTION
Warnings are indicated when mishandling this product might result in death or serious injury
to user.
Cautions are indicated when mishandling this product might result in minor injury to the user,
or only physical damage to the timer.
WARNING
RESTRICTIONS ON USE
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install failsafe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary. This product is rated
at Class
.
Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has
been correctly wired before turning the power ON.
Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause
electric shock.
Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
Do not disassemble the product. Doing so might cause electric shock or faulty operation.
CAUTION
Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere etc.). Failure to do so might cause fire or faulty operation.
Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.
SPECIFICATIONS
Operating voltage
AC/DC : 24240V
Allowable operating
voltage range
Rated frequency
50 / 60Hz
Contact rating
Reset time
MAX 0.1s
Power consumption
Approx. 3VA
Life
POWER
LEDs
Ambient humidity
MAX 85% RH
Weight
Approx. 100g
15
20
25
30
sec
Time Dial
Mode Window
Mode Selector
A
10
MODE
OUT
Scale Selector
ANLY H3C-R
BASIC SETTING
CONNECTION
Mode Selector
H3C-R
H3C-R11
A
Mode Window
7
1
GATE
Scale Selector
Turn the Mode Selector with a screwdriver in either
clockwise or counter-clockwise direction until the
desired operation mode (A, A4, B, B3, B4, C, E, or J) is visible through the Mode Window. Make sure
the selector snaps into a secured position, not between two modes.
5 6 7
4
8
9
3
2
10
1 11
5
START
4
3
RESET
Groove for
screwdriver
Turn the Scale Selector with a screwdriver and the time scale will cycle through all values.
Stop when the desired scale range (1.2, 3, 12, 30) and the scale unit (sec, min, hrs, 10h) are visible
through the Scale Range Windows and the Scale Unit Window respectively.
Clockwise turns increment the time scale; counter-clockwise turns decrement the scale.
Make sure the selector snaps into a secured position, not between two scales.
SOURCE
SOURCE
A : ON delay (2C)
t
Rt
Rt t - a
t - a Rt
E : Interval (1A1C)
t
SOURCE (2-7)
SOURCE (2-7)
SOURCE (2-7)
N.C. (8-5)
N.O. (8-6)
OUTPUT LED
N.C. (8-5)
N.O. (8-6)
OUTPUT LED
POWER LED
Set time = t , t - a < t , Reset time = Rt
N.C. (1-4)
N.C. (1-4)
N.O. (1-3)
N.O. (1-3)
POWER LED
Rt
Rt t - a
SOURCE (2-7)
SOURCE (2-7)
N.C. (8-5)
N.O. (8-6)
OUTPUT LED
N.C. (8-5)
N.O. (8-6)
OUTPUT LED
t - a Rt
0.6s
0.6s
0.6s
0.6s
N.C. (8-5)
N.O. (8-6)
OUTPUT LED
N.C. (1-4)
N.C. (1-4)
N.C. (1-4)
N.O. (1-3)
N.O. (1-3)
POWER LED
Set time = t , t - a < t , Reset time = Rt
t - a Rt
C : Interval (2C)
t
SOURCE (2-7)
SOURCE (2-7)
Rt
Rt t - a
POWER LED
POWER LED
Set time = t , t - a < t , Reset time = Rt
0.5s
POWER LED
Set time = t , t - a < t , Reset time = Rt
Rt
Rt t - a
SOURCE (2-7)
N.O. (1-3)
POWER LED
Rt t - a
POWER LED
Set time = t , t - a < t , Reset time = Rt
A4 : ON delay (1A1C)
Rt
Pr oduc t is s u b j e c t t o c h a n g e w i t h o u t n o t i c e .
0.5s
A : ON delay (2C)
SOURCE (2-10)
t-a
t-a t-a
SOURCE (2-10)
START (2-6)
START (2-6)
RESET (2-7)
RESET (2-7)
POWER LED
Set time = t
E : Interval (1A1C)
A4 : ON delay (1A1C)
t
SOURCE (2-10)
t-a
t-a
SOURCE (2-10)
START (2-6)
START (2-6)
RESET (2-7)
RESET (2-7)
N.C. (11-8)
N.O. (11-9)
OUTPUT LED
N.C. (11-8)
N.O. (11-9)
OUTPUT LED
N.C. (1-4)
N.C. (1-4)
N.O. (1-3)
N.O. (1-3)
POWER LED
POWER LED
Set time = t , t - a < t
Set time = t
t-a
t-a
SOURCE (2-10)
SOURCE (2-10)
START (2-6)
START (2-6)
RESET (2-7)
RESET (2-7)
N.C. (11-8)
N.O. (11-9)
OUTPUT LED
0.5s
0.5s
N.C. (1-4)
POWER LED
Set time = t , t - a < t
N.O. (1-3)
POWER LED
Set time = t , t - a < t
t-a
t1
SOURCE (2-10)
SOURCE (2-10)
START (2-6)
START (2-6)
RESET (2-7)
GATE (2-5)
N.C. (11-8)
N.O. (11-9)
OUTPUT LED
RESET (2-7)
N.C. (1-4)
N.C. (11-8)
N.O. (11-9)
OUTPUT LED
N.O. (1-3)
POWER LED
t2
t-a
POWER LED
Set time = t , t - a < t
t-a
*Note. While the start signal is ON, the timer starts when power
comes ON or when the reset input goes OFF.
SOURCE (2-10)
START (2-6)
RESET (2-7)
N.C. (11-8)
N.O. (11-9)
OUTPUT LED
0.6s
0.6s
0.6s
0.6s
N.C. (1-4)
N.O. (1-3)
POWER LED
Set time = t , t - a < t
DIMENSION(mm)
H3C-R or H3C-R11
6.5
52
14.2
51
15
6.5
37
35.7
30
45
45 +0.5
-0
13
48
48
36.7
48
45
48
48
45
45
48
36.7
3.3 X 2
45 +0.5
-0
59
M-H3CR-J-A
Printed in Taiwan