Indoor unit
Cylinder unit
Model name
EHST20C
-VM6HA
Heat exchanger
Casing
Booster heater
Immersion heater
X
X
X
X
X
-
X
-
Solar circuit
mm
2%
230 / Single / 50
230 / Single / 50
400 / Three / 50
Floor standing
RAL 9001
230 / Single / 50
230 / Single / 50
230 / Single / 50
230 / Single / 50
230 / Single / 50
400 / Three / 50
230 / Single / 50
230 / Single / 50
400 / Three / 50
6 (2/4/6)
26
9 (3/6/9)
13
6 (2/4/6)
26
6 (2/4/6)
26
9 (3/6/9)
13
Breaker
32
16
32
16
32
32
16
230 / Single / 50
230 / Single / 50
13
13
16
16
1.1*2
1.1*2
1.1*2
1.1*2
1.1+1.1 (Solar)
m
L
14*2
14*2
14*2
14*2
14+14 (Solar)
6.8*2
6.8+6.8 (Solar)
Current
Breaker
A
2
Material
Room temperature
Flow temperature
Legionella prevention
6.8*2
Capacity
(A7/W35)
COP
Stainless steel
Stainless steel
Stainless steel
200
Duplex
stainless steel
(EN10088)
0~35
200
Duplex
stainless steel
(EN10088)
0~35
200
Duplex
stainless steel
(EN10088)
0~35
200
Duplex
stainless steel
(EN10088)
0~35
10~30
10~30
10~30
10~30
10~30
10~30
25~60
25~60
25~60
25~60
25~60
25~60
40~60
40~60
40~60
40~60
40~60
Max 70
Max 70
Max 70
Max 70
Max 70
28
28
28
28
28
28
28
* The enviroment must be frost-free
kW
RP35VHA4
RP50VHA4
RP60VHA4
RP71VHA4
RP100V/YKA
RP125V/YKA
RP140V/YKA
HRP71VHA2
HRP100V/YHA2
HRP125YHA2
4.10
6.00
7.00
8.00
11.20
14.00
16.00
8.00
11.20
14.00
4.14
3.73
4.29
4.21
4.31
4.24
4.10
4.40
4.26
4.22
Power input
kW
0.99
1.61
1.63
1.90
2.60
3.30
3.90
1.82
2.63
3.20
Heating
Capacity
kW
4.10
5.00
6.80
7.50
10.50
11.50
11.80
8.00
11.20
14.00
(A2/W35)
COP
2.93
2.50
2.94
2.92
2.90
2.70
2.78
3.24
3.02
2.70
1.40
2.00
2.31
2.57
3.62
4.26
4.24
2.47
3.71
5.19
kW
Heating
dB
46
46
48
48
51
52
52
52
52
52
Dimensions
Height
mm
600
600
943
943
1338
1338
1338
1350
1350
1350
Width
mm
800
800
950
950
1050
1050
1050
950
950
950
Depth
mm
300+23
300+23
330+30
330+30
330+30
330+30
330+30
330+30
330+30
330+30
Optional parts
Cylinder uint
Increase
in occupants Lights turned off
IMMERSION HEATER
WIRELESS REMOTE CONTROLLER
WIRELESS RECEIVER
REMOTE SENSOR
JOINT PIPE
JOINT PIPE
PAC-IH03V-E
PAR-WT40R-E
PAR-WR41R-E
PAC-SE41TS-E
1Ph 3kW
PAC-SH50RJ-E
PAC-SH30RJ-E
15.88
9.52
Energy savings
2
Room temp.
Temperature
setting
Flow temp.
12.7
6.35
EHSC-VM9A
Auto Adaptation function maximizes both comfort and energy savings without the need for complicated settings.
EHSC-VM6A
Accordingly, room temperature can be kept stable, enhance energy-saving and optimum room comfort can be achieved simultaneously.
Hydro box
EHST20C-VM6SA
Specification
Model name
EHST20C-YM9A
Parts name
Furthermore, by estimating future changes in room temperature, the system works to prevent unnecessary increases in the flow temperature.
Hydro box
Service access
Service access
Parameter
Dimension(mm)
Parameter
Dimension(mm)
300
200
150
150
10
500
500
500
3
Outdoor temp.
12:00
18:00
24:00
Comfort
6:00
0~35
25~60
EHST20C-VM6A
Our newly introduced Auto Adaptation function measures the room temperature and outside temperature, then calculates the required heating
capacity for the room. Simply stated, the flow temperature is automatically controlled according to the required heating capacity, while optimal
room temperature is maintained at all times, ensuring the appropriate heating capacity and preventing wasted energy.
0~35
10~30
EHST20C-VM6HA
Stainless steel
200
Duplex
stainless steel
(EN10088)
0~35
dB(A)
6.8*2
Stainless steel
DHW
6.8*2
Power input
Pre-coated
metal
54
Wall mounted
Volume
Heating
RAL 9001
Pre-coated
metal
54
Wall mounted
9 (3/6/9)
13
EHST20C-YM9HA
Outdoor temp.
RAL 9001
Pre-coated
metal
131
Floor standing
Current
Model Name(PUHZ-)
variables is difficult.
Curtain opened
RAL 9001
6 (2/4/6)
26
Heating
RAL 9001
Temperature/Heating Load
230 / Single / 50
230 / Single / 50
Heat exchanger
Operating range
Pre-coated
metal
130
Floor standing
Coil:Material
1c
Pre-coated
metal
130
Floor standing
Coil Capacity
RAL 9001
Flow temp.
X
-
Pre-coated
metal
131
Floor standing
Immersion heater
Domestic
hot water tank
X
-
X
-
RAL 9001
this means that comfort and energy savings are dramatically affected by controlling the flow temperature in the system.
X
X
-
Pre-coated
metal
131
Booster heater
EHSC-YM9A
X
-
kg
EHSC-VM6A
Aiming to realise further comfort and energy savings, Mitsubishi Electric is proud to introduce a new revolutionary system control. This is based on data
achieve the optimal heat curve according to the heating load of each
individual residence.
Material
In conventional system control, the flow temperature is determined based on the preset Heat curve depending on the actual outdoor temperature.
EHST20C
-VM6SA
RAL code
Type of Installation
indicating that a 1 C drop in the flow temperature improves the coefficient of performance (COP) of the air-to-water (ATW) system by 2%. In simple terms,
EHST20C
-YM9A
Heater
Hydro box
EHST20C
-VM6A
HxWxD
Dimensions
EHST20C
-YM9HA
The cylinder unit must be located indoors and in a frostfree environment, for example in a utility room, to minimise
heat loss from stored water.
Time
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
http://Global.MitsubishiElectric.com
Room temp.
Target temp.
3 points
T0
T1 Current
Future
Time
User-friendly Operation
Fast, Simple Installation
User-friendly, intuitive operation through simple layout of buttons and easy to understand icons.
Pure white design matches virtually any interior.
Simplified: All key functional components are incorporated into the unit.
Easy servicing: Relevant parts located at the front of the unit
Compact Cylinder Unit Design: 5951,600680mm (WHD)
Installation is possible in low-ceiling basements and within the standard size for home appliances. Only 0.405 required.
Compact Hydro box Unit Design: 530x800x360mm (WxHxD)
Easy to transport and install using the attached handle (Cylinder unit) and a back plate (Hydro box unit)
MANOMETER
EXPANSION VESSEL
(behind)
EXPANSION VESSEL
HANDLES (back)
CONTROL AND
ELECTRICAL BOX
MAIN REMOTE
CONTROLLER
CONTROL AND
ELECTRICAL BOX
3-WAY VALVE
BOOSTER HEATER
WATER PUMP
PAR-WR41R-E
(Option)
PLATE HEAT
EXCHANGER
PUMP VALVE
PAR-WT40R-E
(Option)
TANK
MAIN REMOTE
CONTROLLER
PLATE HEAT
EXCHANGER
BOOSTER HEATER
STRAINER
IMMERSION
HEATER*
STRAINER
MANOMETER
FLOW SWITCH
ADJUSTER
HANDLE
ZUBADAN 5HP
Heating
capacity (kW)
15
ZUBADAN 4HP
10
Power
Power
-25oC
-20oC
-15oC
P
INV 5H ZUBADAN
3HP
P
INV 4H
-7oC
0oC
ZUBADAN 3-5HP