Professional Documents
Culture Documents
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
1
11/8/2015
Specifier's comments:
1 Input data
Anchor type and diameter:
HVZ M16x105
Material:
8.8
ETA 03/0032
Issued I Valid:
6/4/2013 | 6/4/2018
Proof:
Stand-off installation:
eb = 0 mm (no stand-off); t = 30 mm
Anchor plate:
Profile:
Base material:
cracked concrete, C30/37, fc = 37.00 N/mm2; h = 1000 mm, Temp. short/long: 30/40 C
Reinforcement:
no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
with longitudinal edge reinforcement d >= 12 + close mesh (stirrups, hangers) s <=
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
2
11/8/2015
Shear force y
3.750
3.750
3.750
3.750
x
Tension
3
Steel Strength*
Pullout Strength*
Concrete Breakout Strength**
Splitting failure**
* anchor having the highest loading
Capacity [kN]
60.000
Utilization bN [%]
24
Status
OK
N/A
N/A
N/A
N/A
47.498
49.443
97
OK
47.498
74.164
65
OK
gM,s
1.500
NRd,s [kN]
60.000
NSd [kN]
14.101
A0c,N [mm2]
99225
ccr,N [mm]
158
scr,N [mm]
315
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
43
yec2,N
0.786
N0Rk,c [kN]
47.121
gM,c
1.500
NRd,c [kN]
49.443
NSd [kN]
47.498
Ac,N [mm2]
223000
A0c,N [mm2]
99225
ccr,sp [mm]
158
scr,sp [mm]
315
yh,sp
1.500
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
43
yec2,N
0.786
ys,N
0.890
N0Rk,c [kN]
47.121
gM,sp
1.500
NRd,sp [kN]
74.164
NSd [kN]
47.498
ys,N
0.890
yre,N
1.000
k1
7.200
yre,N
1.000
k1
7.200
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
3
11/8/2015
Capacity [kN]
40.800
Utilization bV [%]
10
Status
OK
N/A
N/A
N/A
N/A
Pryout Strength**
15.297
125.737
13
OK
15.297
150.982
11
OK
gM,s
1.250
VRd,s [kN]
40.800
VSd [kN]
3.824
Ac,N [mm2]
223000
A0c,N [mm2]
99225
ccr,N [mm]
158
scr,N [mm]
315
k-factor
2.000
ec1,V [mm]
0
yec1,N
1.000
ec2,V [mm]
0
yec2,N
1.000
ys,N
0.890
N0Rk,c [kN]
47.121
gM,c,p
1.500
VRd,c1 [kN]
125.737
VSd [kN]
15.297
a
0.102
b
0.071
yec,V
1.000
yre,N
1.000
dnom [mm]
18.0
k1
1.700
c1 [mm]
100
Ac,V [mm2]
165000
A0c,V [mm2]
45000
ys,V
1.000
yh,V
1.000
ya,V
2.280
ec,V [mm]
0
V0Rk,c [kN]
19.347
gM,c
1.500
VRd,c [kN]
150.982
VSd [kN]
15.297
yre,V
1.400
bV
0.122
a
1.000
Status
OK
10.445 [kN]
dN
0.127 [mm]
VSk
2.833 [kN]
dV
0.237 [mm]
dNV
0.269 [mm]
10.445 [kN]
dN
0.425 [mm]
VSk
2.833 [kN]
dV
0.355 [mm]
dNV
0.554 [mm]
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
4
11/8/2015
7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!
Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
The design method ETAG (filled holes) assumes that no hole clearance between the anchors and the fixture is present. This can
be
achieved by filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling
the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means.
The compliance with current standards (e.g. EC3) is the responsibility of the user
An SLS-check is not performed for SOFA and has to be provided by the user!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
5
11/8/2015
8 Installation data
Anchor plate, steel: Custom; E = 205000.00 N/mm2; fyk = 275.00 N/mm2 Anchor type and diameter: HVZ M16x105
Profile: Pipe; 140 x 140 x 13 mm
Installation torque: 0.090 kNm
Hole diameter in the fixture: df = 18 mm
Hole diameter in the base material: 18 mm
Plate thickness (input): 30 mm
Hole depth in the base material: 125 mm
Recommended plate thickness: calculated
Minimum thickness of the base material: 210 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
Cleaning
Manual blow-out pump
Setting
HVA square drive shafts
Dynamic set
Torque wrench
100
50
100
450
250
300
250
450
100
50
4
100
x
0
0
0
0
y
400
150
-150
-400
c-x
100
100
100
100
c+x
100
100
100
100
c-y
-
c+y
-
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
6
11/8/2015
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan