You are on page 1of 1

1

Do not scale this drawing.


Dimensions to be taken on site and all discrepancies reported to the CA

B-B
200

Extent of site boundary

B-B1

29
52

Extent of application site.

30

205
Gu
tte
r

Alumasc coping
system

Rooflight over
winter garden

30
0

Rwp

Gu
t

ter

26
90

66
5
Rwp

TFW21

11
35

89

TFW13

Bl

oc

9 28
18

Rwp

Dining

69
25

34

34

00

29

77

Winter
Garden

5
32

TFW06

Separating wall

Green roof

TFW01

19
77

112

314

45

TFW05

30

206

30
0

19

F-F

200 x 200
boiler flue hole
in roof
98

70 TFD01

200 x 200
boiler flue hole
in roof

Living Room

system

417

225

27

226
7

Rwp

12

FFL
+61.585
Alumasc coping

2A

TFW14

22

HW

308

Rwp

108

295

249

259

34
2

Alumasc coping
system

6
25

TFW07

Separating wall

0
20

200 x 200
hole
svp

Dining

Living Room

12

0
20

4
39

4
49

48

65
56

0
20

TFW16

50

200 x 200
boiler flue hole
in roof

2
2

27
1

47

Kitchen

30

Dining

98

30

Rwp

TFW09

21
24

5
66

Flat 7
No 9

HW

87

0
89

60

24

Separating wall

20

2 no 250 x 200
holes cables

21

13

TFW15

Common
Lobby

20
9
259

29

0
90
1Winter
Garden

341
241

200 x 200
hole
svp

350

200

TFW03

Rwp

TFD03

TFW11

1416

190

256

Kitchen

TFD04

Separating wall

256
200

200

for gas and

100
1859

200

1400

200 x 200
boiler flue
hole in roof

200 x 200
hole
svp

100

665

910

1600

Accessible
Bathroom

HWC

342

1654

Lift 2

1360

TFW18
Separating wall

TFD05

08.12.15 Separating wall dimensions amended.

24.07.15 Doors and window references added.

05.06.15 Construction Issue as Roadfern Ltd email


instruction 04.06.15. New columns overlaid
as DHK 04.06.15

02.06.15 Lift shaft 1 and 2 door openings revised.


Stair cores and stairs 5 and 6 drawing cross
references added.

15.05.15 Grid lines added 2A 8A 8B. Lift shaft 1 and 2


revised. Coordination with DHK structural
columns as PDF drawing issues.

30.04.15 Coordination with DHK structural drawings.


Svp /cable/rwp holes revised as ADA mark
ups issued 24.04.15 . Lift 2 depth dim revised
to suit Thyssen Krupp. Annotation revised.
issue drawings. Annotation revised.

24.03.15 Coordination with DHK/Syntegra Tender


issue drawings. Annotation revised.

2900

502

4702

Bedroom

2 no 250 x 200
holes cables

1980

890

Rwp

256

200

270

for smoke ventilation

750

Flat 8
No 5

+60.640

Common
Lobby

300

Rwp

TFW12

water

svp

TFW04

Riser

200 x 200
hole
svp

Winter
Garden

240

Rwp

Living Room

0
0

48

12

3
34

Separating wall

271

305

256

TFW19

665

Dining

271

HW

96

67

03

17

Flat 7
No 5

Bedroom

B
ck

48

TFW17

200 x 200
boiler flue hole
in roof

30

12

97

136

TFW20

Blo

670

33

25

03

55

200

TFW10

Kitchen

93

Living Room

200

Bedroom

13

75

42
21

900

24

200

6
25

16 Lift 1
50

65

Separating wall

200 x 200
hole
svp

Accessible
Bathroom

53
10

29

19
50

20

200 x 200
hole
dry riser

73

48

72

25

for gas and water

08

32

12

TFD02
TF

Riser

+61.435

1m AOV above stair well


for smoke ventilation

00

28

ventilated riser

204

Accessible
Bathroom

Flat 6
No 9

20
0

Maintenance access door

A -A

0
19
23

Rwp

Kitchen

Rev G

TFW02

27

Rwp

392

158

42
79

n
tio
Sta ad
Ro

Bedroom

35
29

200 x 200
hole
svp

22
25

30

91

555

Gutter

333

249

200

2439

1099

200 x 200
boiler flue hole
in roof

Area TBC by MEP


Engineer

TFW22

910

3608

901

2300

Ladder to
roof above

Rooflight over
winter garden

3018

342

841

885

250

200

200

348

841

1302

300

Rwp

FFL Green roof


+60.640

Alumasc coping
system

2888
Green roof

2215

200 x 200 svp


hole in roof

200

99

80

Rwp

274

583

300

Alumasc coping
system

247

349

200 x 200
boiler flue hole
in roof

207

200

Alumasc coping
system

4118

200 x 200 svp


hole in roof

2800

300

Gutter

G-G

2723

204

3947

300

200

98

299

1800mm
high dividing wall

300
Rwp

1022

591

577

TFW26
TFW25

Mansard
Roof

C-C
202

Private roof garden

FFL
+59.950

300

Sliding opening
roof light for
roof access

Paving
slabs

300

Paving
slabs

1019

DATE

COMMENTS

8B

TFW23
Alumasc coping
system

200

H-H

Riser from below


including Svp and bin store vent

137

REV

Rooflight over
winter garden

904

200 x 200 svp


hole in roof
slab through
riser

5811

3810

FFL
+59.950

8A
Block C

Private roof garden

3810

Alumasc coping
system

Sliding opening
roof light for
roof access

Alumasc coping
system

Gutter

200 x 200 svp


hole in roof

300

200 x 200 svp


hole in roof

33

47

200

200

300

200

200

Rwp

8111

E-E

200

208

Rwp
2061

TFW24

Mansard
Roof

Rwp

Rwp

2800

Alumasc coping
system

Gutter

301

Mansard
Roof

10701

300

Gutter

300

1450

Rooflight over
winter garden

9
PROJECT:

Deerfields 1-3 Station Road


Hendon NW4 4QA

3600

Mapesbury
Mews

SUBJECT:

D-D
203

General Arrangement
Third Floor Plan
DRAWING NO:

SCALE:

WD/333/104
DATE:

1:100 @ A1

DRAWN BY:

RL

CHECKED BY:

RL
REV:

Jan 2015

Copyright Reserved