MCH
620
Basic
function
Symbol
_MCH620_SetAutoMode
Unit No.
Axis No.
Automatic Mode enabled
File name
Applicable
models
Conditions
for usage
Function
description
(BOOL)
EN
(BOOL)
ENO
(INT)
UnitNo
(INT)
Axis
(BOOL)
Enable
(BOOL)
Status
(BOOL)
OK
(BOOL)
Error
(WORD)
ErrorID
Mode flag
Normal
Error flag
Error code
Lib\FBL\omronlib\PositionController\MCH\_MCH620_SetAutoMode10.cxf
Motion Control Unit
CS1W-MCH71, CJ1W-MCH71
CPU Unit
CS1*-CPU**H Unit version 3.0 or higher
CJ1*-CPU**H Unit version 3.0 or higher
CJ1M-CPU** Unit version 3.0 or higher
CP1H
CX-Programmer
Version 5.0 or higher
None
When Automatic Mode enabled (Enable) turns ON, the Operating Mode of the Motion Control Unit allocated an
axis specified with Unit No. (UnitNo) and Axis No. (Axis) will be switched to Automatic Mode. When it turns
OFF, the Motion Control Unit will be switched to Manual Mode. For details, refer to the manual listed in Related
manuals.
Mode flag (Status) will reflect status of Automatic Mode enabled (Enable) as soon as the command is received.
The Error Flag (Error) will be turned ON and the Error Code (Error code) will be output if an error occurs for this
FB. These statuses are not output for errors of other FBs or instances.
These statuses will be reset when Automatic Mode enabled (Enable) turns OFF. If Automatic Mode enabled
(Enable) turns OFF before the Operating Mode is switched to Automatic Mode, the status will be set for at least
one cycle when a corresponding condition occurs.
EN
ON
OFF
ENO
ON
OFF
Enable
ON
OFF
Status
ON
OFF
OK or
Error
FB
precautions
EN input
condition
Restrictions
Other
ON
OFF
For bit address calculation, these bits are read inside the FB when executing each instance for the
first time, or when the Input Variables Unit No. (UnitNo) and Axis No. (Axis) are changed and then
Automatic Mode enabled (Enable) is turned ON.
_MCH620_SetAutoMode (2/2)
Application
example
The Servomotor (J01) connected to the Motion Control Unit of the Unit No. 0 is switched to Automatic Mode.
Unit No.: 0
&0
CPU
MCH
Servomotor
J01
Always ON (P_On)
Unit No.
&0
Axis No.
J01 &1
Automatic Mode enabled
Bit A
Related
manuals
Bit E
_MCH620_SetAutoMode
(BOOL)
EN
(BOOL)
ENO
(INT)
UnitNo
(INT)
Axis
(BOOL)
Enable
(BOOL)
Status
(BOOL)
OK
(BOOL)
Error
(WORD)
ErrorID
Mode flag
Bit B
Normal
Bit C
Error flag
Bit D
Error code
Variable Tables
Input Variables
Name
Variable name
EN
EN
Data type
BOOL
Default
Range
Unit No.
Axis No.
UnitNo
Axis
INT
INT
&0
&1
&0 to &15
&1 to &32
Automatic
Mode enabled
Enable
BOOL
0(OFF)
Output Variables
Name
ENO
Variable name
ENO
Data type
BOOL
Mode flag
Status
BOOL
Normal
OK
BOOL
Error flag
Error code
Error
ErrorID
BOOL
WORD
Version History
Version
1.00
Date
2005.4
Range
Description
1 (ON): Starts FB
0 (OFF): Does not start FB
Specify the Axis No. Managed in the Motion Control
Units. Note that this is different from the Node
Address used in the MECHATROLINK network.
: Switches to Automatic Mode
: Switches to Manual Mode
Description
1 (ON): FB operating normally
0 (OFF): FB not operating normally/FB ended with error
1 (ON): In Automatic Mode
0 (OFF): In Manual Mode
1 (ON) indicates that the states of Automatic Mode
enabled (Enable) and Mode flag (Status) match with each
other.
1 (ON) indicates that an error has occurred in the FB.
The error code of the error occurred in the FB will be
output. For details of the errors, refer to the manual listed
in the Related manuals above. When Unit No. or Axis No.
is out of the range, #0000 will be output.
Contents
Original production
Note
This manual is a reference that explains the function block functions.
It does not explain the operational limitations of Units, components, or combinations of Units and components. Always read
and understand the Operation Manuals for the systems Units and other components before using them.