Professional Documents
Culture Documents
TYPE:
PROJECT:
A1238 Wide 75
A4239 Wide 75
4 3/8" Round Downlights
1100, 1500 and 2000 lumen
Philips Fortimo Remote Phosphor
OPTICS and APPLICATIONS
Downlight optical systems have been engineered to produce high efficiencies
and soft pattern while maintaining excellent brightness control.
Vent
Slot
MultiSource
Cover
Housing
Top
Plug-in
Connectors
Branch Circuit
Junction Box
Electronic
Driver
Philips Fortimo
Module
Heat
Sink
Alzak
Cone
GENERAL
Fixture is pre-wired and thermal protected, UL and C-UL listed for damp
locations and eight wire 75 C, branch circuit wiring. All products are union
made. Designed and manufactured in the USA.
Thermal
Protector
WARRANTY
5 Year Warranty. See www.kurtversen.com for details or select hyperlink.
ENERGY INFORMATION
D
Module Delivered System
Fixture
Lumens
Lumens
Watts
lm/W
A1238 1100 1008 15 67.2
1500
1298
21
61.8
A4239
2000
1732
28
61.9
Number
A
Depth
B
C
Aperture Width
D
Length
LED
Module
A1238
8 1/4"
210mm
4 3/8"
111mm
13 1/8"
333mm
13 3/4"
349mm
1100 lm or 1500 lm
Philips Fortimo
A4239
9 1/8"
232mm
4 3/8"
111mm
15 7/8"
403mm
16 3/8"
416mm
2000 lm
Philips Fortimo
ORDERING GUIDE
Base Specification (required)
Example: A1238-153012D or A4239-203012D
Options (optional)
Model
Source
Lumens
Kelvin
Volts
Dimming
Cone
Finish
Cone
Color
Cone
Paint
Flush
Mount
Fuse
EM
Support
Rails
A1238
Wide
A4239
Wide
11 1100
15 1500
20 2000
(2000 lm
A4239 only.)
27 2700K
30 3000K
35 3500K
40 4000K
12 120V
27 277V
Standard
Specular clear
SS SoftSheenTM
S Softglow
Standard clear
B Black
G Gold
W Wheat
Y Pewter
Standard clear
WT White Flange.
WHT White Cone,
complete.
F Fuse.
REM Remote
EM. Includes
battery pack,
charger light,
test switch for
90 minutes.
Remote mount
only. Ceiling
access required.
R2 26"
R5 52"
Products
designated
FMR4
provided
with
FMBKT
Performance Datachart
Single Unit Initial Footcandles, 30" Work Plane
Ceiling to Floor
20
30
Ceiling 80%
Walls 50%
Floor 20%
40
FC
FC
Diam
FC
Diam
FC
Diam
Spacing
RCR 1
RCR 3
RCR 8
25
32
18
23
13
17
10
13
8
11
21
28
15
20
12
15
9
12
7
9
4'
4'
5'
5'
5'
5'
6'
6'
7'
7'
14
18
10
13
8
10
6
8
5
6
6'
6'
8'
8'
9'
9'
10'
10'
11'
11'
4
5
3
3
2
3
2
2
1
2
9'
9'
11'
11'
13'
13'
14'
14'
16'
16'
7'
7'
8'
8'
9'
9'
10'
10'
12'
12'
25
32
18
23
13
17
10
13
8
11
21
27
15
19
11
15
9
11
7
9
15
19
11
14
8
10
6
8
5
6
8'
9'
10'
11'
12'
Ceiling to Floor
20
30
Walls 50%
Floor 20%
40
FC
Diam
FC
Diam
FC
Diam
Spacing
RCR 1
RCR 3
RCR 8
43
37
4'
25
6'
9'
8'
7'
49
42
29
30
26
5'
18
8'
11'
9'
8'
35
30
21
23
20
5'
13
9'
13'
10'
9'
26
23
16
18
15
6'
10
10'
14'
11'
10'
20
18
12
14
12
7'
11'
16'
12'
12'
16
14
10
See note 2.
Candlepower Distribution
85
75
75
150
65
225
Candelas
85
100
75
200
65
45
375
450
55
400
45
500
525
35
700
675
900
1170
25
1000
45
15
25
35
910
1040
15
55
650
800
65
520
600
750
75
260
780
600
35
85
130
390
300
55
300
1300
15W
15
25
A1238 Philips Fortimo 1100 lm A1238 Philips Fortimo 1500 lm A4239 Philips Fortimo 2000 lm
3000K S/M 1.23
3000K S/M 1.23
3000K S/M 1.23
Luminous efficacy 67.2
Luminous efficacy 61.8
Luminous efficacy 61.9
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Notes
21W
28W
969
973
966
978
1010
977
858
615
316
128
10
5
4
3
0
0
0
0
0
1287
1292
1283
1295
1338
1300
1145
827
427
173
14
7
5
4
0
0
0
0
0
Vertical Angles
* Luminaire Lumens
One Paragon Drive, Suite 157, Montvale, NJ 07645 / Tel 201.664.8200 / Website www.kurtversen.com
2016 Kurt Versen, a division of Hubbell Lighting, Inc. / A1238 A4239 / Rev1 Date 2/12/2016
Because of continuing product improvement programs, Kurt Versen reserves the right to change specifications without notice.
1 Photometric Reports:
A1238 (1100 lm)
KV Report No. 22114,
A1238 (1500 lm)
KV Report No. 22014-A,
A4239 KV Report No. 22014.
2 Datachart degree headings
show one side of nadir.
Diameter data includes both
sides. Therefore the 10
column shows a 20 pattern
diameter at the work plane.
Footcandle values are at
the diameter edge.
3 Specular colored cone
multipliers, contact factory.
4 Softglow and SoftSheenTM
cone multipliers, contact
factory.
5 The luminous efficacy
(lm/W) refers to the total
measured luminous flux
(lumens) of the fixture
divided by the total
measured electrical input
power (watts) of the
complete fixture.