You are on page 1of 10

Crossroad Development Property Sewer Line Extension Phase II

Beckley , WV

TABLE OF CONTENTS

General Description

Location Map

FEMA NFIP Flood Map

4-6

Design Calculations

Form EG-4

Form ES-69

Crossroad Development Property, LLC


Crossroad Development Property Sewer Line Extension Phase II
Beckley, West Virginia
Project Description

Crossroad Development Property, LLC, with the City of Beckley, is proposing to install approximately 988
feet of 8 inch SDR 35 gravity sewer line off Route 16 also called Robert C. Byrd Drive. This proposed
sewer line extension will serve a proposed shopping center, four box stores, a motel, and a church. The
sewer extension will be connected to an existing line in the subdivision that will tie to the sewer line
installed to serve Crossroad Chevrolet and Phase I of the Crossroad Development.
Please find attached the information, plans, and details required to submit a permit for a sewer line
extension.

DESIGN CALCULATIONS
FOR
CROSSROAD DEVELOPMENT - PHASE II
SEWER LINE EXTENSION

AVERAGE DAILY FLOW


Proposed Sites:
Shopping Center
Box Store=
Box Store=
Box Store=
Box Store=
Motel=
Church=

15
15
15
15
15
50
5

gpd / 100 sf
gpd / 100 sf
gpd / 100 sf
gpd / 100 sf
gpd / 100 sf
gpd / person
gpd / person

60,000
40,000
40,000
40,000
40,000
300
600

sf
sf
sf
sf
sf
persons
persons

/
/
/
/
/
/
/

100 sf * 15 gpd=
100 sf * 15 gpd=
100 sf * 15 gpd=
100 sf * 15 gpd=
100 sf * 15 gpd=
300 people * 50 gpd=
600 members * 5 gpd=

9,000
6,000
6,000
6,000
6,000
15,000
3,000

gpd
gpd
gpd
gpd
gpd
gpd
gpd

Average Daily Flow


51,000

ADF

127,500

gpd

PEAK FLOW
Peak flow = 2.5 x ADF
Peak flow=

2.5 x

51,000 ADF=

Hydraulic Radius
R = A/P
Using a 8 in diameter pipe.
R = Hydraulic Radius (ft.)
A = Cross-sectional Area of Flow (sq. ft.)
P = Wetted perimeter (ft.)

0.17
0.35
2.09

ft
sq ft.
ft

DESIGN CALCULATIONS
FOR
CROSSROAD DEVELOPMENT - PHASE II
SEWER LINE EXTENSION

Area

A= r2
r = radius of pipe
A = area

0.33
0.35

ft
sq ft

2.09
0.33

ft
ft

0.57
0.20
0.35

ft/sec
cu. ft/sec
sq ft

Wetted perimeter (ft.)

P = 2r
P = Wetted perimeter (ft.)
r = radius of pipe

Velocity
V = Q/A
V = Velocity
Q = Discharge
A = Area

DESIGN CALCULATIONS
FOR
CROSSROAD DEVELOPMENT - PHASE II
SEWER LINE EXTENSION

Manning's Formula
Slope of pipe (from design) =

0.056

ft/ft

Assuming flowing full


Required slope of pipe = ((V x n) / (1.49 x R .66))2

Q = Discharge (cu. ft./sec.)


A = Cross-sectional Area of Flow (sq. ft.)
n = Coefficient of Roughness
R = Hydraulic Radius (ft.)
S = Slope of Pipe (ft./ft.) (Minimum Required)

Design pipe slope is greater than required. Therefore, pipe is ok.

0.20
0.35
0.013
0.17
0.00027

cu ft. / sec
sq. ft.
ft.
ft./ft

EG-4
06/2010
WEST VIRGINIA DEPARTMENT OF HEALTH AND HUMAN RESOURCES
Bureau for Public Health
Office of Environmental Health Services

350 Capitol Street, Room 313


Charleston, WV 25301-3713
Phone: 304-558-2981 Fax: 304-558-0691

SEWAGE SYSTEM INFORMATION AND DESIGN DATA SHEET


Complete all portions of the Design Data Sheet applicable to the project. Omission of required information will
result in the application being denied. When both sewer system and water system are to be constructed, Design Data
Sheets for both sewage and water must be completed and attached to the application.

Applicant

Crossroad Development Property, LLC

Project Location Robert C. Byrd Drive


County

Raleigh

Total area of site 20.54


Type of development

acres

Area to be developed 20.54

Commercial

Industrial

Existing
Number of

acres

Residential
Proposed

home sites
mobile home sites
camping trailer sites
camp sites

Shops, Church

other
Can development be expanded?

yes

no

Sewer line material (ASTM, AWWA or ANSI designation)


Length of sewer lines of each
size

If so, to what number? unknown

SDR 35

988 feet 8 inch line

Number of manholes/cleanouts 4 proposed manholes


Pump/lift station capacity, gpm n/a
Distance of sewer lines from water lines (horizontal/vertical)