Professional Documents
Culture Documents
2 LiftStationOverview PDF
2 LiftStationOverview PDF
Lift Stations
Types of Collection System Lift Stations
Submersible Pump Lift Station
Dry-Well
Dry Well Lift Station
Control Panel
& Alarm
Valve Vault
Wet well
Valves
Multiple Pumps
Valve Vault
Collection
System
inlet
Float Switch
Control Panel
Alarm
Al
Pumps
D=8
H=1
H=1
Source:http://www.libertypumps.com
Source: www.sewagejector.net
Hatch- Access
to Valve Vault
Hatch- Access
to pumps
Control Panel
Pump
p Operation
p
- Manually operate pumps
- Review data from flow
meters or measure
pressure in discharge
forcemain
Measure p
pump
p voltage
g and
amperage
- High or low amperage readings
may indicate
i di t problem
bl
Grinder Pump
Grinder Pump
Lift raw wastewater to collection system
Reduces the size of solids in wastewater by
grinding
g
g them into a slurry
y
Large horsepower pump
Smaller diameter forcemain
Wet well has short retention time
Pumps
Valves & Controls
Ventilation
Receiving
W t W ll
Wet-Well
Wet Well
Wet-Well
Alarm
Valves
Inlet
Dry-well
Dry
well Vault
Control Panel
Pumps
Source: Norweco - PosaPrime
Float Switches
Dry Well
Dry Well Size- Dry Pump Room
Space for operator
Lift Pumps
Ventilation System
Valves
Control Panel
Sump pump for floor drain
Enclosed Panel
Wired to pumps and float switches
O
Operator
can manually
ll controll pumps
Sounds high water alarm/ Display Visual Alarm
S
Some
feature
f t
connection
ti to
t an auto-dialer
t di l tto alert
l t
operator of alarm
Emergency Response
Emergency Operating Procedures
Educate community
Quick response to back ups or Alarms
- Respond within 4-6 hours
- Response
p
time depends
p
on emergency
g
y storage
g
volume and flow into wet well
Emergency Power
Portable emergency generator available to
provide
id power d
during
i llong outages
t
Electrical adaptor for connection of portable
generator power to control panel
Emergency Power
Lift stations with generator located on site
ATS Auto Transfer Switch
Exercise standby
power source weekly
Safety-Potential hazards
Classified as Confined Space
Exposure to Gases
Portable gas meter
- Hydrogen Sulfide (rotten egg smell)
- Ventilation (30 minutes min.)
- Operators should be advised of procedures and
precautions
Electrical Safety
y
code awareness
Hygiene
yg
and exposure
p
to wastewater
Maintenance Activities
Safety
Minimum of two trained
employees for service
calls
p p
Access to a lift for pump
service that requires
pump removal
Source: doonwoodengineering
doonwoodengineering.com
com