Professional Documents
Culture Documents
74'-52
1"
11'-42
31'-11"
7'-1"
1"
10'-112
7'-4"
1"
5'-82
6'-3"
1"
24'-72
5'-8"
1"
6'-62
1"
16'-82
7'-11"
3056 MULL
5'-9"
8'-10"
6'-5"
14'-2"
POST
W.I.C.
3'-0"
1"
15'-12
3056 MULL
CTC3
3'-6"
10'-2"
67'-4"
1"
13'-12
1"
14'-22
8'-0"
VAULTED
CEILING
21'-0"
QUOIN CORNER
8'-83
4"
1"
17'-52
2'-0"
4'-111
4"
1"
4'-114
2'-0"
8'-23
4"
1"
13'-102
8'-23
4"
1"
16'-52
1"
38'-62
16'-3"
VAULTED CEILING
GARAGE
QUOIN CORNER
49'-0"
1"
25'-102
FLAT CEILING
VAULTED CEILING
VAULTED
CEILING
8'-83
4"
5'-0"
2'-6"
42"X36"
3'-2"
1"
6'-02
2'-8"
2'-8"
9'-6"
VAULTED CEILING
VAULTED
VAULTED
CEILING
CEILING
QUOIN CORNER
1"
37'-102
1"
11'-42
1"
15'-42
1"
11'-42
1"
5'-42
FLAT CEILING
2,525
985
3,510
662
208
1"
4'-82
3'-0"
VAULTED
CEILING
RANGE
1"
4'-42
6'-0"
3'-0" CABED
OPENING
2456
244CT24
QUOIN CORNER
DINING ROOM
11'-2"
3056 MULL
CTC3
4'-4"
7'-2"
3056 MULL
CTC3
2'-1"
1"
6'-12
10'-4"
FRONT PORCH
GARAGE
4" CONCRETE SLAB FLOOR
SLOPE TO DOOR 2"
2'-1"
12'-0"
QUOIN CORNER
8'-0"
3'-0"
13'-9"
1"
12'-112
3'-0"
4'-0"
4'-0"
3'-0"
CABED
OPENING
3'-4"
VAULTED CEILING
R.O. FOR BYFOLD DOORS USING DRYWALL JAMS FACING IS 1 1/4" + DOOR SIZE
9'-0"
4'-0"
FLAT CEILING
FRONT DOOR
WITH TRANSOM
1"
14'-72
4'-6"
10'-0"
14'-0"
14'-8"
BEDROOM
NO. 3
1"
7'-62
4'-5"
2'-4"
VAULTED
CEILING
3'-0" CABED
OPENING
2'-1"
SMOKE DETECTORS
INTERCONNECTED
WITH 110V. (BATTERY
BACKUP)
FOYER
SD
KITCHEN
4'-0"
6'-6"
73" X 66"
2'-6"
3'-6"
4'-8"
WH
2'-8"
9'-10"
DBL WALL
1"
6'-72
4'-0"
3'-4"
3050 MULL
DBL WALL
W.I.C.
1"
26'-42
CABINET DETAIL
PG. 8C
REF.
2'-4"
5'-0"
1"
14'-72
1'-10"
73" X 51"
4'-8"
36" X 66"
3049 MULL
2'-4"
3056
D/W
5'-0" BYPASS
36" X 57"
OVERHANG
2'-0"
2'-1"
1"
3'-32
3049
VENT TO
OUTSIDE
1"
4'-22
36" X 36"
60" VAN.
9'-6"
3030
BATH
SD
1"
2'-92
R.O. SIZE
2'-6"
8'-0"
ANDERSEN WINDOWS
MODEL
3'-6"
5'-0" BYPASS
41'-0"
FLOORPLAN
1"
21'-92
ATTIC
ACCESS
22"X30"
67'-4"
1"
9'-112
GREAT ROOM
3'-8"
8'-2"
2'-4"
8'X0" BYPASS
1"
9'-52
SMOKE DETECTORS
INTERCONNECTED
WITH 110V. (BATTERY
BACKUP)
SD
3'-2"
2'-8"
1"
15'-12
17'-0"
2'-4"
BATH
9'-6"
1"
6'-02
BREAKFAST
AREA
24" O.C.
VAULTED
CEILING
VAULTED
CEILING
TH
R
EA
H
24" O.C.
ACTIVE PANEL
DIRECT VENT
FIREPLACE
64
"
BEDROOM
NO. 2
1"
14'-82
1"
15'-42
SD
32'-5"
ALL PREFABRICATED
FIREPLACES SHOULD BE
INSTALLED PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
36" VAN.
2'-6"
13'-9"
1"
2'-62
5'-9"
2'-0"
4'-8"
3056 MULL
ATTIC
ACCESS
22"X30"
4'-9"
3056 MULL
72" VAN.
MIRROR ON BEDROOM
SIDE OF DOOR
18' LIN.
SD
3'-2"
3'-9"
VENT TO
OUTSIDE
12'-0"
SMOKE DETECTORS
INTERCONNECTED
WITH 110V. (BATTERY
BACKUP)
40"X48" GLASS
BLOCK WINDOW
18'-4"
BATH
2'-6"
2'-4"
18'-4"
18'-4"
OWNER'S SUITE
60"x42"
WHIRLPOOL
TUB
2'-4"
COVERED
PORCH
QUOIN CORNER
11'-2"
22'-4"
1"
74'-52
DRAWING
DATE:
Jason O'Brien
CLASS
DSN 113
DWG NO.:
10/26/15
001
SCALE:
1:1