You are on page 1of 24

GEA Unit Heaters For retail and industrie

Flexible, powerful, diversified


GEA MultiMAXX
Product Brochure

engineering for a better world

GEA Heat Exchangers

With GEA MultiMAXX for optimal solutions

Efficiency and cost-effectiveness for


decentral air treatment

You can achieve your goal only by employing components exactly matched to your requirements. The GEA MultiMAXX family offers
the most reliable, most efficient, and most cost-effective solution for each profile of specifications. The great diversity of the individual
GEA MultiMAXX air-treatment components is your guarantee for the optimal solution.

Fans

Sickle-blade fan, IP 54

Wide-blade fan, IP 54

Wide-blade fan, EEx

Diagonal-blade fan, IP 54

Copper/Copper

Galvanized steel

Stainless steel

Heat exchangers

Copper/Aluminum

[2]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX unit heaters

Planning freedom for decentral


air handling
In the planning of a decentral air-handling system, those exercising responsibility must be sure that carefully targeted
and flawless solutions can be provided for simple as well as
for highly specialized applications. And this is the reason why
so many experts view the GEA MultiMAXX family as an absolute essential.
Its name is program. Multifunctional application possibilities,
application-specific materials properties, as well as demand-optimized air treatment components provide the guarantee for the
most efficient and cost-effective solution.
Even the operation of a high-efficiency energy-recuperation system is a matter without difficulty with employment of the complete GEA MultiMAXX Ergo system. For more detailed information on these possibilities, please see our separate documentation.

The short overview below shows what GEA makes possible, in


the individual model ranges HNHSHXHDHEHP*
Housings galvanized steel sheet, coated finish, or
stainless steel
Motors IP 54 enclosure-protection class, with EEx e
for enhanced safety, and EEx d in models with pressureresistant enclosures
Fans wide-, sickle-, and diagonal-blade versions
Heat exchangers Cu-Al, Cu-Cu- galvanized steel, stainless
steel, electro
Air-filter pads filter grades G2 G4 in accordance with EN 779
Air-filter bags filter grades G2 F7 in accordance with EN 779
Air intake 23 versions for recirculated-air and mixed-air
modules
Air outlet 13 versions, some with motor drive
Heating function pumped warm water (PWW)
or pumped hot water (PHW)
Cooling function pumped chilled water (PCW),
2-pipe system
System control GEA MATRIX
*

The HP sub-range is part of the HN range. HP models are on stock and can be delivered
immediately.

PR-2010-0003-GB Subject to modifications K2-10/2012

[3]

Product overview

Meets all requirements


For ceiling or wall installation
GEA MultiMAXX HN the universal solution
For employment in trade and industrial sectors, with
the functions heating cooling ventilation
Five model sizes: 1 5
IP 54 motors 1-phase, 230 V; 3-phase, 400 V;
3-phase, 500 V; with 1, 2, and 3 speeds
Fans wide-blade and sickle-blade
Heat exchangers Cu-Al, Cu-Cu, galvanized steel,
fully zinc-plated steel
Enclosure design or industrial versions
(zinc-plated or coated)

GEA MultiMAXX HS the hygienic solution


For employment in applications with strict hygienic
requirements, with the functions heating cooling
Four model sizes: 1 4
IP 54 motors 3-phase, 400 V; with 2 speeds
Fans wide-blade
Heat exchangers galvanized steel, fully zinc-plated steel,
stainless steel
Enclosure industrial version (stainless steel)

GEA MultiMAXX HX the ultra-safe solution


For employment in applications in explosion-endangered areas,
with the functions heating ventilation cooling
Four model sizes: 1 4
EEx motors 3-phase, 400 V; 3-phase, 500 V;
with 1 and 2 speeds; enhanced safety features;
with pressure-resistant enclosure
Fans wide-blade
Heat exchangers Cu-Al, Cu-Cu, galvanized steel,
fully zinc-plated steel, stainless steel
Enclosure industrial version (zinc-plated, coated,
or stainless steel)

[4]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX HD the high-pressure solution


For applications with high air-side resistance levels, and
with F7-grade air filtration in accordance with VDI 6022 as
option, with the functions heating ventilation
Four model sizes: 1 4
IP 54 motors 3-phase, 400 V; 3 speeds
Fans diagonal-blade
Heat exchangers Cu-Al, Cu-Cu, galvanized steel
Enclosure design or industrial versions (zinc-plated
or coated)

GEA MultiMAXX HE the electric unit heater


For employment in areas without supply of warm water,
with the functions heating ventilation
Three model sizes: 1, 2, and 4
IP 54 motors 3-phase, 400 V; 3-phase, 500 V *;
2 and 3 speeds*
Fans wide-blade and sickle-blade*
Heat exchangers Cu-Al, Cu-Cu, galvanized steel,
fully zinc-plated steel
Enclosure industrial version (coated)
3-phase, 500 V only with sickle blades; 3 speeds for model size 2

GEA MultiMAXX HP
the fast one, on stock in the logistics center
Same as the GEA MultiMAXX HN model, but with predefined technical characteristics featuring only the heating
function
Three model sizes: 1 3
IP 54 motors 3-phase, 400 V; 2-speed
Fans wide-blade
Heat exchanger Cu-Al
Enclosure industrial versions (zinc-plated)
Air outlets wall basic, wall profile, ceiling basic,
ceiling profile
Since the characteristics of this model are limited as
listed here, fast delivery from the logistics center is
possible.
PR-2010-0003-GB Subject to modifications K2-10/2012

[5]

Thermal air-flow patterns

Maximum efficiency from secondary air


Great thermal lift, without including secondary air
Ceiling temperature = 23 C; height of hall-type room = 12 m

0.6 m
Limited air-projection range

Time required to heat


up to the required
temperature of 17 C

1.75 m

Air speed
0.3 m/s
Comfort zone

Flow patterns on the air-outlet side, with standard air outlets

[6]

PR-2010-0003-GB Subject to modifications K2-10/2012

Optimized thermal lift as a result of including secondary air


Ceiling temperature = 19 C; height of hall-type room = 12 m

0.2 m
Variable air-projection range
Air speed:
variable from 4-10 m/s

Time required to heat


up to the required
temperature of 17 C

1.75 m
Additional
secondary air
Air speed
0.2 m/s

Comfort zone

Flow patterns on the air-outlet side, with use of a secondary-air louver

PR-2010-0003-GB Subject to modifications K2-10/2012

[7]

GEA MATRIX intelligent control technology

Just the right turn for the right room climate


If requested, the proven GEA MATRIX control unit will be integrated into the GEA MultiMAXX at the factory. Your benefit: only completely tested equipment will be supplied to your
construction site.
GEA MATRIX is available in configuration levels 2000, 3000, or
4000, with adaptation to the various possible applications. Most
of the versions are provided with the GEA MATRIX.Net dualcable bus system as default, through which all GEA MATRIX
units can communicate with each other. As a result, it is simple
to implement daytime and nighttime switching actions, and to
control pumps and collect error messages at a single point. GEA
MATRIX can also be connected to higher-level bus systems.
In addition, GEA MATRIX assures energy-optimized operation
of the GEA MultiMAXX. By means of the summer compensation
function, GEA MATRIX takes into account outside-temperature
influences and therefore prevents energy-intensive climate control.
Comprehensive control possibilities

Hardware and software are developed entirely at GEA. As a re-

Control functions in various expansion stages

sult of close collaboration in the company, GEA engineers can

Bus interfaces to other equipment units

systematically adjust the control system to match every compo-

Plug-and-play functionality

nent and in turn optimally exploit the possibilities of the units.

Energy-optimized equipment operation

GEA support staff also profit from this arrangement by being

Equipment ready to operate

able to quickly and expertly react in case of any questions.

Highly competent service


Global add-on modules

Numerous additional global modules are available as function

LON interface

expansions of the standard-version local connections of the MA-

Service tools

TRIX control system. Examples here are: intra-group operator


panels and clock modules, modules for activation control of exhaust-air fans and chillers, expansion of analog or digital input
and output signals, 0 10-V outputs for valves, and integration
into a LON bus system in accordance with the LonWorks standard.
All modules can be simply integrated via the MATRIX.Net bus
system. In addition, the service tools MATRIX.PDA and MATRIX.PC can be used for parameterization, initial startup, maintenance, and data recording from the MATRIX control system.

[8]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MATRIX

Operator panels

Operator panel for MATRIX 2000

MATRIX OP 21
Enclosure without display, pure white
Recirculated-air operation,
IP 20 enclosure-protection class*
Desired-temperature setting
Fan-speed selection switch for permanent
operating mode
Button for temperature-reduction mode
LED display: operation / malfunction /
external influence
Integrated room-temperature sensor
MATRIX.Net data bus: network interface for MATRIX add-on
module via operator panel OP 21

Operator panels for MATRIX 3000 and MATRIX 4000

Operator panels for MATRIX 3000 and MATRIX 4000

MATRIX OP 31

MATRIX OP 44

Enclosure without display, pure white


Recirculated-air operation,
IP 20 enclosure-protection class*
Desired-temperature setting
Button for temperature-reduction mode
Fan-speed selection switch for permanent /
automatic operating modes
LED display: operation / malfunction /
external influence
Integrated room-temperature sensor

Same as the OP31 control unit, but with

Operator panels for MATRIX 3000 and MATRIX 4000

Operator panels for MATRIX 3000 and MATRIX 4000

MATRIX OP 50 without clock


MATRIX OP 51 with clock

Example: IP 54 enclosure-protection class


MATRIX OP 51

Enclosure with display, pure white


Recirculated-air /
mixed-air modes of operation
IP 20 enclosure-protection class*
Operation by rotary navigator
LCD display with plain text
Status report by pictograms
Integrated room-temperature sensor

Function: same as IP 20 enclosureprotection class, but with loose enclosed


room-temperature sensor

Switching for heating / cooling /


automatic modes of operation
Switching for recirculated-air /
mixed-air modes of operation
All control units are without display.
With protective cover as option.

A s option: IP 54 enclosure-protection class, with loose enclosed room-temperature sensor

GEA Series MC thermostat/fan-speed selection switch


Simple thermostat controls are also available for minimal control-system requirements.
Optional with additional contacts for 2-point control activation of louvers and valves.

MC303

MC303

PR-2010-0003-GB Subject to modifications K2-10/2012

MC302K

MC333

Room thermostat IP 54

[9]

GEA MultiMAXX

Complete program

Heating / cooling with GEA MultiMAXX

[5 system versions:
HN, HS, HX, HD, HE]
[5 model sizes] [5100 kW]
[1,000 13,000 m3/h]
Decentral solutions for mixed und outdoor air

With a complete program for each area of operation, the GEA MultiMAXX system satisfies requirements placed on decentral air handling
by users in trade, commerce, and industry. The HN and HX ranges furthermore make cooling operations possible via a 2-conductor
change-over function: for both wall and for ceiling installation.

[10]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MAXX Ergo

System energy recuperation

Energy recuperation with GEA MAXX Ergo

[F7 outdoor-air filter]


[7 44 kW] [3 model sizes]
[12 duty levels]
[1,000 7,700 m3/h]
High-efficiency supply-air system with F7 filter

The extraordinary component diversity of GEA MultiMAXX is rounded off by the GEA MAXX Ergo, the high-efficiency energy-recuperation system. The GEA MAXX Ergo offers a high-efficiency liquid-coupled energy-recovery system for decentral ventilation of hall-type
buildings: such as production floors, logistics facilities, and many other similar possibilities. Combined with the GEA MATRIX control
system, the GEA MAXX Ergo implements a maximum of cost efficiency. For detailed information on this possibility, please consult our
separate product brochures at www.gea-airtreatment.com This system is provided only as complete assemblies, including extracted-air
unit, hydraulics modules, and the GEA MATRIX control system.

PR-2010-0003-GB Subject to modifications K2-10/2012

[11]

HN range: heating

GEA MultiMAXX

Model sizes
IP 54 sickle-blade fan

Duty
1 2 3 4

HN 1




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

2,460
8.4
8
2,140
9.7
7

2,170
6.3
12
1,950
7.5
12

1,970
5.2
17
1,810
6.3
16

1,830
4.5
20
1,700
5.5
19

HN 2




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

3,810
9.3
12
3,570
11.5
12

3,630
7.5
20
3,400
9.3
19

3,410
6.5
26
3,210
8.1
25

3,240
5.7
33
3,050
7.1
32

HN 3




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range
Heating duty

m/h
m
kW
m/h
m
kW

5,890
10.1
19
5,400
12.4
18

5,450
7.9
31
5,030
9.8
30

5,080
6.8
41
4,720
8.4
39

4,770
5.9
50
4,470
7.4
48

HN 4




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

9,170
11.4
29
8,250
13.5
27

8,340
8.8
47
7,610
10.6
45

7,680
7.4
61
7,100
9.0
58

7,170
6.4
76
6,700
7.9
72

HN 5




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

12,570
12.3
39
11,420
15.2
38

11,500
9.6
63
10,580
12.0
61

10,790
8.2
84
10,020
10.4
80

9,970
7.1
104
9,330
9.0
100

System characteristics





Sickle-blade fan
3-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED MIN
Technical data for MAX speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50C; air entry 18C

Dimensions for
Model sizes
design enclosures
Wall installation


HN 1


HN 2


HN 3


HN 4


HN 5
1

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
642

642

571

34 38

72

58

738

738

586

41 47

75

60

866

866

587

58 68

73

59

1,026

1,026

667

82 98

78

64

1,154

1,154

649

108 129

80

66

M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

[12]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX

HN range: heating or cooling

Model sizes
IP 54 wide-blade fan

Duty
1 2 3 4

HN 1




Air flow for basic air outlet


Air-projection range for wall installation
Heating / cooling duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating / cooling duty

m/h
m
kW
m/h
m
kW

1,900
6.7
7/3
1,610
7.6
6/2

1,640
5.6
11/4
1,440
5.9
10/4

1,460
4.1
14/6
1,310
4.9
13/6

1,330
3.5
16/8
1,220
4.3
15/8

HN 2




Air flow for basic air outlet


Air-projection range for wall installation
Heating / cooling duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating / cooling duty

m/h
m
kW
m/h
m
kW

3,160
7.9
11/5
2,740
9.2
11/4

2,780
6.0
18/7
2,430
7.1
16/6

2,470
5.0
22/9
2,190
6.0
20/8

2,220
4.3
26/13
2,010
5.2
24/12

HN 3




Air flow for basic air outlet


Air-projection range for wall installation
Heating / cooling duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating / cooling duty

m/h
m
kW
m/h
m
kW

4,860
8.6
17/7
4,300
10.2
16/7

4,350
6.6
28/11
3,900
7.9
26/10

3,940
5.5
35/15
3,580
6.7
33/14

3,620
4.8
41/20
3,330
5.9
39/19

HN 4




Air flow for basic air outlet


Air-projection range for wall installation
Heating / cooling duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating / cooling duty

m/h
m
kW
m/h
m
kW

7,680
9.8
26/11
6,920
11.6
25/10

6,990
7.2
43/17
6,310
9.6
41/16

6,390
6.4
55/23
5,810
7.7
51/22

5,870
5.5
66/32
5,390
6.7
62/31

HN 5




Air flow for basic air outlet


Air-projection range for wall installation
Heating / cooling duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating / cooling duty

m/h
m
kW
m/h
m
kW

9,210
9.4
34/14
8,440
11.8
33/13

8,630
7.6
55/21
7,970
9.5
53/21

8,030
6.5
70/30
7,460
8.2
67/29

7,530
5.7
85/42
7,050
7.3
82/40

System characteristics






Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MED MIN
Technical data for MED speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50 C; air entry 18C
Cooling medium: PCW 6 / 12 C; air entry 27C / 46%

Dimensions for
Model sizes
design enclosures
Wall installation


HN 1


HN 2


HN 3


HN 4


HN 5

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
642

665

631

33 ... 37

66

51

738

761

646

40 ... 46

67

53

866

889

647

57 ... 66

68

54

1,026

1,049

727

80 ... 96

73

59

1,154

1,177

709

106 ... 126

71

57

Measuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

PR-2010-0003-GB Subject to modifications K2-10/2012

[13]

HS range: heating

GEA MultiMAXX

Model sizes
IP 54 wide-blade fan
Duty
1 * 2 * 3 *
HS 1







HS 2







HS 3







HS 4





Air flow for basic air outlet


m/h

Air-projection range for wall installation
m
Heating duty
kW
Air flow for profile-louver air outlet
m/h
Air-projection range for wall installation
m
Heating duty
kW
Maximum weight
kg



Air flow for basic air outlet
m/h
Air-projection range for wall installation
m
Heating duty
kW
Air flow for profile-louver air outlet
m/h
Air-projection range for wall installation
m
Heating duty
kW
Maximum weight
kg



Air flow for basic air outlet
m/h
Air-projection range for wall installation
m
Heating duty
kW
Air flow for profile-louver air outlet
m/h
Air-projection range for wall installation
m
Heating duty
kW
Maximum weight

2,590
10.2
5
2,280
11.1
4
47

4,180
11.7
8
3,690
12.7
8
58

6,130
12.0
13
5,380
13.0
12
86

1,810
5.3
12
1,710
6.1
12
81

2,920
6.1
20
2,730
6.9
19
106

4,200
6.1
31
3,940
7.0
29
153

4,300
7.1
22
4,020
8.0
21
146

Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for profile-louver air outlet
Air-projection range for wall installation
Heating duty
Maximum weight

10,400
14.1
22
9,000
15.0
20
122

7,030
7.2
52
6,620
8.1
50
208

7,190
8.3
36
6,740
9.4
35
206

m/h
m
kW
m/h
m
kW
kg

1,840
6.3
7
1,730
7.2
7
75
3,000
7.1
13
2,800
8.0
13
100

System characteristics




Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED
Technical data for MAX speed level

LG 1 = heat exchanger 1RR, zinc-plated steel, with 6.0-mm louvers


LG 2 = heat exchanger 2RR, zinc-plated steel, with 3.0-mm louvers
*
LG 3 = heat exchanger 3RR, stainless steel V4a, with 2.8-mm louvers

Heating medium: PWW 70/50C; air entry 18C
*

Dimensions for
Model sizes
industrial enclosures
Wall installation


HS 1


HS 2


HS 3


HS 4

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
642

520

521

47 ... 81

71

67

738

616

536

58 ... 106

76

62

866

744

537

86 ... 153

76

62

1,026

904

617

122 ... 298

81

67

Measuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

[14]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX

HX range: heating

Model sizes
IP 54 wide-blade fan EEx

Duty
1 2 3 4

HX 1
Air flow for basic air outlet
m/h
2,660
2,340
2,130
1,980

Air-projection range for wall installation
m
9.0
6.7
5.5
4.8

Heating duty
kW
8
13
17
21

Air flow for profile-louver air outlet
m/h
2,330
2,120
1,970
1,860

Air-projection range for wall installation
m
9.6
7.4
6.2
5.5

Heating duty
kW
7
12
17
20

HX 2
Air flow for basic air outlet
m/h
4,300
3,990
3,710
3,450

Air-projection range for wall installation
m
10.3
8.1
6.9
6.0

Heating duty
kW
13
21
28
35

Air flow for profile-louver air outlet
m/h
3,910
3,650
3,410
3,200

Air-projection range for wall installation
m
11.4
9.1
7.8
6.8

Heating duty
kW
12
20
26
33
HX 3
Air flow for basic air outlet
m/h
5,800
5,190
4,740
4,390

Air-projection range for wall installation
m
10.0
7.6
6.4
5.6

Heating duty
kW
19
30
39
47

Air flow for profile-louver air outlet
m/h
5,180
4,730
4,380
4,100

Air-projection range for wall installation
m
10.9
8.5
7.2
6.3

Heating duty
kW
18
29
37
45

HX 4
Air flow for basic air outlet
m/h
9,190
8,230
7,530
6,990

Air-projection range for wall installation
m
11.4
8.7
7.3
6.3

Heating duty
kW
29
47
60
75

Air flow for profile-louver air outlet
m/h
8,210
7,510
6,980
6,550

Air-projection range for wall installation
m
12.4
9.6
8.2
7.2

Heating duty
kW
27
44
57
71

System characteristics





Wide-blade fan EEx-e (safety class EEx-d upon request)


2-speed motor; 3-phase 400 V EEx-e
Fan-speed ranges: MAX MED
Technical data for MAX speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50C; air entry 18C

Dimensions for
Model sizes
industrial enclosures
Wandmontage


HX 1


HX 2


HX 3


HX 4

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
642

520

521

32 36

71

57

738

616

536

40 46

75

61

866

744

537

57 67

73

59

1,026

904

617

83 99

80

66

Measuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

PR-2010-0003-GB Subject to modifications K2-10/2012

[15]

HD range: heating

GEA MultiMAXX

Model sizes
IP 54 diagonal-blade fan

Duty
1 2 3 4

HD 1




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

2,800
9.4
8
2,570
11.3
8

2,600
7.3
14
2,420
8.9
13

2,440
6.1
19
2,280
7.5
18

2,430
5.6
25
2,270
6.9
23

HD 2




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

4,680
11.1
13
4,310
13.6
13

4,350
8.8
22
4,040
10.8
21

4,080
7.5
29
3,820
9.3
28

3,850
6.5
37
3,630
8.2
36

HD 3




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

6,610
11.2
20
6,310
14.1
19

6,340
9.0
34
6,070
11.4
33

6,100
7.8
45
5,850
10.0
44

5,880
7.0
57
5,650
8.9
56

HD 4




Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW

13,350
15.7
33
12,530
19.4
32

12,610
12.4
57
11,900
15.3
56

11,980
10.7
78
11,360
13.2
76

11,430
9.3
102
10,890
11.6
99

System characteristics

Diagonal-blade fan

3-speed motor; 3-phase 400 V; IP 54

Fan-speed ranges: MAX MED MIN

Technical data for MAX speed level

Heat exchanger: Cu/Al

Heating medium: PWW 70/50C; air entry 18C

Dimensions for
Model sizes
design enclosures
Wall installation


HD 1


HD 2


HD 3


HD 4
1

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
642

642

852

54 58

77

63

738

738

975

76 83

79

65

866

866

1,076

103 114

84

70

1,026

1,026

1,236

159 175

89

75

M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

HD range with high-efficiency energy recuperation via a liquid-coupled system, together with the GEA RoofJETT.
For more details, please see the separate GEA MAXX Ergo documentation.

Ceiling installation
Model sizes
Max. air flow (m/h)
Heat-recovery efficiency
Ergo duty (kW)


HD 2
2,300
63%
36

HD 3

3,800

54%

52

HD 4

7,700

50%

65

Data for the Ergo duty: taken from separate GEA MAXX Ergo documentation

[16]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX

HE range: heating

Model sizes
IP 54 wide-blade fan Duty (heating levels)
1
2
3
HE 1
Air flow for basic air outlet
m/h
2,470
2,470
2,470

Air-projection range for wall installation
m
8.2
8.2
8.2

Heating duty
kW
4
8
12

Air flow for profile-louver air outlet
m/h
2,200
2,200
2,200

Air-projection range for wall installation
m
8.8
8.8
8.8

Heating duty
kW
4
8
12

Air flow for secondary-air louver
m/h
2,180
2,180
2,180

Air-projection range for wall installation
m
9.5
9.5
9.5

Heating duty
kW
4
8
12

HE 2
Air flow for basic air outlet
m/h
3,980
3,980
3,980

Air-projection range for wall installation
m
9.3
9.3
9.3

Heating duty
kW
7
14
21

Air flow for profile-louver air outlet
m/h
3,560
3,560
3,560

Air-projection range for wall installation
m
10.0
10.0
10.0

Heating duty
kW
7
14
21

Air flow for secondary-air louver
m/h
3,520
3,520
3,520

Air-projection range for wall installation
m
10.8
10.8
10.8

Heating duty
kW
7
14
21
HE 4







Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for profile-louver air outlet
Air-projection range for wall installation
Heating duty
Air flow for secondary-air louver
Air-projection range for wall installation
Heating duty

m/h
m
kW
m/h
m
kW
m/h
m
kW

9,900
12.3
14
8,800
13.1
14
8,710
14.1
14

9,900
12.3
28
8,800
13.1
28
8,710
14.1
28

9,900
12.3
42
8,800
13.1
42
8,710
14.1
42

System characteristics






Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED
Technical data for MAX speed level
Heat exchanger: electric heating battery
Heating medium: 3-phase 400 V; operating range = -5C +40C
IP 42 enclosure-protection class (as per EN60529)

Dimensions for
Model sizes
industrial enclosures
Wall installation


HP 1


HP 2


HP 4
1

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
520

642

387

23 34

71

56

616

738

387

28 41

76

61

904

1,026

452

53 77

81

66

M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

PR-2010-0003-GB Subject to modifications K2-10/2012

[17]

HP range: heating (data from Series HN; delivery ex warehouse)

GEA MultiMAXX

Model sizes
IP 54 wide-blade fan
Duty
1 2
HP 1







Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for profile-louver air outlet
Air-projection range for wall installation
Heating duty
Air flow for basic air outlet, 2 sides
Max. suspension height for ceiling installation
Heating duty

m3/h
m
kW
m3/h
m
kW
m3/h
m
kW

2,200

6.4

12
2,010

7.1

12
2,150

7.3

12

HP 2







Air flow for basic air outlet


m3/h
Air-projection range for wall installation
m
Heating duty
kW
Air flow for profile-louver air outlet
m3/h
Air-projection range for wall installation
m
Heating duty
kW
Air flow for basic air outlet, 2 sides
m3/h
Max. suspension height for ceiling installation
m
Heating duty

3,620

7.5

20
3,280

8.3

19
3,520

7.5

20

HP 3







Air flow for basic air outlet


Air-projection range for wall installation
Heating duty
Air flow for profile-louver air outlet
Air-projection range for wall installation
Heating duty
Air flow for basic air outlet, 2 sides
Max. suspension height for ceiling installation
Heating duty

m3/h 5,840 5,200


m
10.1
7.6
kW
19
30
m3/h 5,180 4,720
m
10.9
8.5
kW
18
29
m3/h 5,660 5,070
m
11.1
7.4
kW
18
30

System characteristics





Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED
Technical data for MAX speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50C; air entry 18C

Dimensions for
Model sizes
industrial enclosures
Wall installation


HP 1


HP 2


HP 3

Max.
width

Max.
height

Max.
depth

Max.
weight

Sound power Sound pressure


level (Lw)
level (Lp)1

mm mm mm kg dB(A)
dB(A)
642

520

521

27 30

71

57

738

616

866

744

572

35 39

76

62

591

46 52

76

62

Selection of available air outlets for Prompt units on stock in the warehouse.

Wall basic

Wall profile

Ceiling basic

Ceiling profile

M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2

[18]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX

Wall versions of air outlets

Air outlets for wall installation

Type B
Basic air-outlet louver


Model sizes

Type P
Profile air-outlet louver

Air outlets
Air-projection ranges
Wall version
V1

V2

V3

Type U
Secondary-air louver

Air flow V1 ... V9


V4
V5
V6

V7

V8

V9

m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h

3,000 2,700 2,400 2,100 1,800 1,500 1,200 900 600


Air-projection range
m m m m m m m m m
Basic louver, 1-side
Profile louver
Secondary-air louver

Type B
Type P
Type U

9.3 8.7 8.0 7.3 6.6 5.8 5.0 4.1 3.2


11.1 10.4 9.6 8.8 7.9 7.0 6.0 5.0 3.8
12.1 11.2 10.4 9.5 8.6 7.6 6.5 5.4 4.1
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
5,000 4,500 4,000 3,500 3,000 2,500 2,000 1,500 1,000


Air-projection range
m m m m m m m m m
Basic louver, 1-side
Type B
Profile louver
Type P
Secondary-air louver
Type U



3

11.0 10.3 9.5 8.7 7.8 6.9 6.0 4.9 3.7


13.2 12.3 11.4 10.4 9.4 8.3 7.2 5.9 4.5
14.4 13.4 12.4 11.3 10.2 9.1 7.8 6.4 4.9
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
7,000 6,300 5,600 4,900 4,200 3,500 2,800 2,100 1,400


Air-projection range
m m m m m m m m m
Basic louver, 1-side
Type B
Profile louver
Type P
Secondary-air louver
Type U



4

11.2 10.4 9.6 8.8 7.9 7.0 6.0 5.0 3.8


13.4 12.5 11.5 10.6 9.5 8.4 7.3 6.0 4.6
14.7 13.7 12.6 11.6 10.4 9.2 7.9 6.6 5.0
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
13,000 11,700 10,400 9,100 7,800 6,500 5,200 3,900 2,600

Air-projection range
m m m m m m m m m

Basic louver, 1-side


Type B
Profile louver
Type P
Secondary-air louver
Type U

m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h

13,000 11,700 10,400 9,100 7,800 6,500 5,200 3,900 2,600

14.0 13.0 12.0 11.0 9.9 8.8 7.6 6.2 4.8


16.7 15.6 14.4 13.2 11.9 10.5 9.0 7.5 5.7
18.2 16.9 15.6 14.3 12.9 11.4 9.8 8.1 6.2


Air-projection range
m m m m m m m m m
Basic louver, 1-side
Profile louver
Secondary-air louver

Type B
Type P
Type U

12.3 11.5 10.6 9.7 8.7 7.7 6.7 5.5 4.2


14.7 13.7 12.6 11.6 10.4 9.2 7.9 6.6 5.0
16.5 15.4 14.2 13.0 11.7 10.4 8.9 7.4 5.6

The data on air-projection ranges applies to a warm-air flow that is 10 K above room temperature.

PR-2010-0003-GB Subject to modifications K2-10/2012

[19]

Ceiling versions of air outlets

GEA MultiMAXX

Ceiling air outlets

Type Z
Basic air-outlet louver


Model sizes

Air outlets
Suspension heights
Ceiling version

Type P
Profile air-outlet louver

V1

V2

V3

Type C
Secondary-air louver

Air flow V1 ... V9


V4
V5
V6

V7

V8

V9

m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h


3,000 2,700 2,400 2,100 1,800 1,500 1,200 900 600

Suspension height
m m m m m m m m m
Basic louver, 2-side
Profile louver
Secondary-air louver

Type Z
Type P
Type C

11.0 9.9 8.8 7.7 6.6 5.5 4.4 3.3 2.2


14.7 13.2 11.7 10.3 8.8 7.3 5.9 4.4 2.9
20.2 18.2 16.2 14.2 12.1 10.1 8.1 6.1 4.0
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
5,000 4,500 4,000 3,500 3,000 2,500 2,000 1,500 1,000

Suspension height
m m m m m m m m m
Basic louver, 2-side
Type Z
Profile louver
Type P
Secondary-air louver
Type C



3

13.7 12.3 11.0 9.6 8.2 6.9 5.5 4.1 2.7


18.3 16.5 14.7 12.8 11.0 9.2 7.3 5.5 3.7
25.2 22.7 20.2 17.6 15.1 12.6 10.1 7.6 5.0
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
7,000 6,300 5,600 4,900 4,200 3,500 2,800 2,100 1,400

Suspension height
m m m m m m m m m
Basic louver, 2-side
Type Z
Profile louver
Type P
Secondary-air louver
Type C



4

13.5 12.2 10.8 9.5 8.1 6.8 5.4 4.1 2.7


18.0 16.2 14.4 12.6 10.8 9.0 7.2 5.4 3.6
24.8 22.4 19.9 17.4 14.9 12.4 9.9 7.5 5.0
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
13,000 11,700 10,400 9,100 7,800 6,500 5,200 3,900 2,600

Suspension height
m m m m m m m m m

Basic louver, 2-side


Type Z
Profile louver
Type P
Secondary-air louver
Type C

m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h

13,000 11,700 10,400 9,100 7,800 6,500 5,200 3,900 2,600

17.9 16.1 14.3 12.5 10.7 8.9 7.2 5.4 3.6


24.0 21.6 19.2 16.8 14.4 12.0 9.6 7.2 4.8
32.8 29.6 26.3 23.0 19.7 16.4 13.1 9.9 6.6

Suspension height
m m m m m m m m m
Basic louver, 2-side
Profile louver
Secondary-air louver

Type Z
Type P
Type C

14.3 12.9 11.5 10.0 8.6 7.2 5.7 4.3 2.9


19.3 17.4 15.4 13.5 11.6 9.7 7.7 5.8 3.9
26.5 23.8 21.2 18.5 15.9 13.2 10.6 7.9 5.3

The data on suspension heights applies to a warm-air flow that is 10 K above room temperature.

[20]

PR-2010-0003-GB Subject to modifications K2-10/2012

GEA MultiMAXX

Ceiling versions of air outlets

Ceiling air outlets

Type L
Air-deflection louver


Model sizes

Type V
Air outlet unit, 4 sides

Air outlets
Suspension heights
Ceiling version

V1

V2

Type A
Air outlet nozzle, square

V3

Air flow V1 ... V9


V4
V5
V6

Type T
Air outlet nozzle, rectangular

V7

V8

V9

m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h


3,000 2,700 2,400 2,100 1,800 1,500 1,200 900 600

Suspension height
m m m m m m m m m
Air-deflection louver
Outlet to 4 sides
Square nozzle
Rectangular nozzle

Type L
Type V
Type A
Type T

8.9 8.0 7.1 6.2 5.3 4.4 3.5 2.7 1.8


6.2 5.6 4.9 4.3 3.7 3.1 2.5 1.9 1.2
16.8 15.1 13.4 11.7 10.1 8.4 6.7 5.0 3.4
16.8 15.1 13.4 11.7 10.1 8.4 6.7 5.0 3.4
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
5,000 4,500 4,000 3,500 3,000 2,500 2,000 1,500 1,000

Suspension height
m m m m m m m m m
Air-deflection louver
Type L
Outlet to 4 sides
Type V
Square nozzle
Type A
Rectangular nozzle
Type T



3

11.0 9.9 8.8 7.7 6.6 5.5 4.4 3.3 2.2


7.7 7.0 6.2 5.4 4.6 3.9 3.1 2.3 1.5
21.0 18.9 16.8 14.7 12.6 10.5 8.4 6.3 4.2
21.0 18.9 16.8 14.7 12.6 10.5 8.4 6.3 4.2
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
7,000 6,300 5,600 4,900 4,200 3,500 2,800 2,100 1,400

Suspension height
m m m m m m m m m
Air-deflection louver
Type L
Outlet to 4 sides
Type V
Square nozzle
Type A
Rectangular nozzle
Type T



4

10.9 9.8 8.7 7.6 6.5 5.5 4.4 3.3 2.2


7.7 6.9 6.1 5.4 4.6 3.8 3.1 2.3 1.5
20.8 18.7 16.6 14.6 12.5 10.4 8.3 6.2 4.2
20.8 18.7 16.6 14.6 12.5 10.4 8.3 6.2 4.2
m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h
13,000 11,700 10,400 9,100 7,800 6,500 5,200 3,900 2,600

Suspension height
m m m m m m m m m

Air-deflection louver
Type L
Outlet to 4 sides
Type V
Square nozzle
Type A
Rectangular nozzle
Type T

m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h m3/h

13,000 11,700 10,400 9,100 7,800 6,500 5,200 3,900 2,600

14.5 13.0 11.6 10.1 8.7 7.2 5.8 4.3 2.9


10.1 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0
27.5 24.7 22.0 19.2 16.5 13.7 11.0 8.2 5.5
27.5 24.7 22.0 19.2 16.5 13.7 11.0 8.2 5.5

Suspension height
m m m m m m m m m
Air-deflection louver
Outlet to 4 sides
Square nozzle
Rectangular nozzle

Type L
Type V
Type A
Type T

11.6
10.4 9.3 8.1 6.9 5.8 4.6 3.5 2.3
8.1 7.3 6.5 5.7 4.9 4.0 3.2 2.4 1.6
22.1 19.9 17.6 15.4 13.2 11.0 8.8 6.6 4.4
22.1 19.9 17.6 15.4 13.2 11.0 8.8 6.6 4.4

The data on suspension heights applies to a warm-air flow that is 10 K above room temperature.

PR-2010-0003-GB Subject to modifications K2-10/2012

[21]

Versions of air-intake units

GEA MultiMAXX

Air-intake modules

Mat-filter module

Bag-filter module

Mixed-air module

Blocking louvre, outdoor air

Flexible intake connector

Rectangular duct

Duct bend

Wall intake hood

Wall weather-protection grate

Spacer for
wall openings

Roof duct

Roof air-intake hood

Flat roof-duct base

[22]

PR-2010-0003-GB Subject to modifications K2-10/2012

PR-2010-0003-GB Subject to modifications K2-10/2012

[23]

We live our values.


Excellence Passion Integrity Responsibility GEA-versity
GEA Group is a global engineering company with multi-billion euro sales and operations in more than
50countries. Founded in 1881, the company is one of the largest providers of innovative equipment and
process technology. GEA Group is listed in the STOXX Europe 600 Index.

www.gea-airtreatment.com