Professional Documents
Culture Documents
GEA MultiMAXX PDF 29 MB PDF
GEA MultiMAXX PDF 29 MB PDF
You can achieve your goal only by employing components exactly matched to your requirements. The GEA MultiMAXX family offers
the most reliable, most efficient, and most cost-effective solution for each profile of specifications. The great diversity of the individual
GEA MultiMAXX air-treatment components is your guarantee for the optimal solution.
Fans
Sickle-blade fan, IP 54
Wide-blade fan, IP 54
Diagonal-blade fan, IP 54
Copper/Copper
Galvanized steel
Stainless steel
Heat exchangers
Copper/Aluminum
[2]
The HP sub-range is part of the HN range. HP models are on stock and can be delivered
immediately.
[3]
Product overview
[4]
GEA MultiMAXX HP
the fast one, on stock in the logistics center
Same as the GEA MultiMAXX HN model, but with predefined technical characteristics featuring only the heating
function
Three model sizes: 1 3
IP 54 motors 3-phase, 400 V; 2-speed
Fans wide-blade
Heat exchanger Cu-Al
Enclosure industrial versions (zinc-plated)
Air outlets wall basic, wall profile, ceiling basic,
ceiling profile
Since the characteristics of this model are limited as
listed here, fast delivery from the logistics center is
possible.
PR-2010-0003-GB Subject to modifications K2-10/2012
[5]
0.6 m
Limited air-projection range
1.75 m
Air speed
0.3 m/s
Comfort zone
[6]
0.2 m
Variable air-projection range
Air speed:
variable from 4-10 m/s
1.75 m
Additional
secondary air
Air speed
0.2 m/s
Comfort zone
[7]
Plug-and-play functionality
LON interface
Service tools
[8]
GEA MATRIX
Operator panels
MATRIX OP 21
Enclosure without display, pure white
Recirculated-air operation,
IP 20 enclosure-protection class*
Desired-temperature setting
Fan-speed selection switch for permanent
operating mode
Button for temperature-reduction mode
LED display: operation / malfunction /
external influence
Integrated room-temperature sensor
MATRIX.Net data bus: network interface for MATRIX add-on
module via operator panel OP 21
MATRIX OP 31
MATRIX OP 44
MC303
MC303
MC302K
MC333
Room thermostat IP 54
[9]
GEA MultiMAXX
Complete program
[5 system versions:
HN, HS, HX, HD, HE]
[5 model sizes] [5100 kW]
[1,000 13,000 m3/h]
Decentral solutions for mixed und outdoor air
With a complete program for each area of operation, the GEA MultiMAXX system satisfies requirements placed on decentral air handling
by users in trade, commerce, and industry. The HN and HX ranges furthermore make cooling operations possible via a 2-conductor
change-over function: for both wall and for ceiling installation.
[10]
The extraordinary component diversity of GEA MultiMAXX is rounded off by the GEA MAXX Ergo, the high-efficiency energy-recuperation system. The GEA MAXX Ergo offers a high-efficiency liquid-coupled energy-recovery system for decentral ventilation of hall-type
buildings: such as production floors, logistics facilities, and many other similar possibilities. Combined with the GEA MATRIX control
system, the GEA MAXX Ergo implements a maximum of cost efficiency. For detailed information on this possibility, please consult our
separate product brochures at www.gea-airtreatment.com This system is provided only as complete assemblies, including extracted-air
unit, hydraulics modules, and the GEA MATRIX control system.
[11]
HN range: heating
GEA MultiMAXX
Model sizes
IP 54 sickle-blade fan
Duty
1 2 3 4
HN 1
m/h
m
kW
m/h
m
kW
2,460
8.4
8
2,140
9.7
7
2,170
6.3
12
1,950
7.5
12
1,970
5.2
17
1,810
6.3
16
1,830
4.5
20
1,700
5.5
19
HN 2
m/h
m
kW
m/h
m
kW
3,810
9.3
12
3,570
11.5
12
3,630
7.5
20
3,400
9.3
19
3,410
6.5
26
3,210
8.1
25
3,240
5.7
33
3,050
7.1
32
HN 3
m/h
m
kW
m/h
m
kW
5,890
10.1
19
5,400
12.4
18
5,450
7.9
31
5,030
9.8
30
5,080
6.8
41
4,720
8.4
39
4,770
5.9
50
4,470
7.4
48
HN 4
m/h
m
kW
m/h
m
kW
9,170
11.4
29
8,250
13.5
27
8,340
8.8
47
7,610
10.6
45
7,680
7.4
61
7,100
9.0
58
7,170
6.4
76
6,700
7.9
72
HN 5
m/h
m
kW
m/h
m
kW
12,570
12.3
39
11,420
15.2
38
11,500
9.6
63
10,580
12.0
61
10,790
8.2
84
10,020
10.4
80
9,970
7.1
104
9,330
9.0
100
System characteristics
Sickle-blade fan
3-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED MIN
Technical data for MAX speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50C; air entry 18C
Dimensions for
Model sizes
design enclosures
Wall installation
HN 1
HN 2
HN 3
HN 4
HN 5
1
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
642
642
571
34 38
72
58
738
738
586
41 47
75
60
866
866
587
58 68
73
59
1,026
1,026
667
82 98
78
64
1,154
1,154
649
108 129
80
66
M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
[12]
GEA MultiMAXX
Model sizes
IP 54 wide-blade fan
Duty
1 2 3 4
HN 1
m/h
m
kW
m/h
m
kW
1,900
6.7
7/3
1,610
7.6
6/2
1,640
5.6
11/4
1,440
5.9
10/4
1,460
4.1
14/6
1,310
4.9
13/6
1,330
3.5
16/8
1,220
4.3
15/8
HN 2
m/h
m
kW
m/h
m
kW
3,160
7.9
11/5
2,740
9.2
11/4
2,780
6.0
18/7
2,430
7.1
16/6
2,470
5.0
22/9
2,190
6.0
20/8
2,220
4.3
26/13
2,010
5.2
24/12
HN 3
m/h
m
kW
m/h
m
kW
4,860
8.6
17/7
4,300
10.2
16/7
4,350
6.6
28/11
3,900
7.9
26/10
3,940
5.5
35/15
3,580
6.7
33/14
3,620
4.8
41/20
3,330
5.9
39/19
HN 4
m/h
m
kW
m/h
m
kW
7,680
9.8
26/11
6,920
11.6
25/10
6,990
7.2
43/17
6,310
9.6
41/16
6,390
6.4
55/23
5,810
7.7
51/22
5,870
5.5
66/32
5,390
6.7
62/31
HN 5
m/h
m
kW
m/h
m
kW
9,210
9.4
34/14
8,440
11.8
33/13
8,630
7.6
55/21
7,970
9.5
53/21
8,030
6.5
70/30
7,460
8.2
67/29
7,530
5.7
85/42
7,050
7.3
82/40
System characteristics
Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MED MIN
Technical data for MED speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50 C; air entry 18C
Cooling medium: PCW 6 / 12 C; air entry 27C / 46%
Dimensions for
Model sizes
design enclosures
Wall installation
HN 1
HN 2
HN 3
HN 4
HN 5
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
642
665
631
33 ... 37
66
51
738
761
646
40 ... 46
67
53
866
889
647
57 ... 66
68
54
1,026
1,049
727
80 ... 96
73
59
1,154
1,177
709
71
57
Measuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
[13]
HS range: heating
GEA MultiMAXX
Model sizes
IP 54 wide-blade fan
Duty
1 * 2 * 3 *
HS 1
HS 2
HS 3
HS 4
2,590
10.2
5
2,280
11.1
4
47
4,180
11.7
8
3,690
12.7
8
58
6,130
12.0
13
5,380
13.0
12
86
1,810
5.3
12
1,710
6.1
12
81
2,920
6.1
20
2,730
6.9
19
106
4,200
6.1
31
3,940
7.0
29
153
4,300
7.1
22
4,020
8.0
21
146
10,400
14.1
22
9,000
15.0
20
122
7,030
7.2
52
6,620
8.1
50
208
7,190
8.3
36
6,740
9.4
35
206
m/h
m
kW
m/h
m
kW
kg
1,840
6.3
7
1,730
7.2
7
75
3,000
7.1
13
2,800
8.0
13
100
System characteristics
Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED
Technical data for MAX speed level
Dimensions for
Model sizes
industrial enclosures
Wall installation
HS 1
HS 2
HS 3
HS 4
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
642
520
521
47 ... 81
71
67
738
616
536
58 ... 106
76
62
866
744
537
86 ... 153
76
62
1,026
904
617
81
67
Measuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
[14]
GEA MultiMAXX
HX range: heating
Model sizes
IP 54 wide-blade fan EEx
Duty
1 2 3 4
HX 1
Air flow for basic air outlet
m/h
2,660
2,340
2,130
1,980
Air-projection range for wall installation
m
9.0
6.7
5.5
4.8
Heating duty
kW
8
13
17
21
Air flow for profile-louver air outlet
m/h
2,330
2,120
1,970
1,860
Air-projection range for wall installation
m
9.6
7.4
6.2
5.5
Heating duty
kW
7
12
17
20
HX 2
Air flow for basic air outlet
m/h
4,300
3,990
3,710
3,450
Air-projection range for wall installation
m
10.3
8.1
6.9
6.0
Heating duty
kW
13
21
28
35
Air flow for profile-louver air outlet
m/h
3,910
3,650
3,410
3,200
Air-projection range for wall installation
m
11.4
9.1
7.8
6.8
Heating duty
kW
12
20
26
33
HX 3
Air flow for basic air outlet
m/h
5,800
5,190
4,740
4,390
Air-projection range for wall installation
m
10.0
7.6
6.4
5.6
Heating duty
kW
19
30
39
47
Air flow for profile-louver air outlet
m/h
5,180
4,730
4,380
4,100
Air-projection range for wall installation
m
10.9
8.5
7.2
6.3
Heating duty
kW
18
29
37
45
HX 4
Air flow for basic air outlet
m/h
9,190
8,230
7,530
6,990
Air-projection range for wall installation
m
11.4
8.7
7.3
6.3
Heating duty
kW
29
47
60
75
Air flow for profile-louver air outlet
m/h
8,210
7,510
6,980
6,550
Air-projection range for wall installation
m
12.4
9.6
8.2
7.2
Heating duty
kW
27
44
57
71
System characteristics
Dimensions for
Model sizes
industrial enclosures
Wandmontage
HX 1
HX 2
HX 3
HX 4
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
642
520
521
32 36
71
57
738
616
536
40 46
75
61
866
744
537
57 67
73
59
1,026
904
617
83 99
80
66
Measuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
[15]
HD range: heating
GEA MultiMAXX
Model sizes
IP 54 diagonal-blade fan
Duty
1 2 3 4
HD 1
m/h
m
kW
m/h
m
kW
2,800
9.4
8
2,570
11.3
8
2,600
7.3
14
2,420
8.9
13
2,440
6.1
19
2,280
7.5
18
2,430
5.6
25
2,270
6.9
23
HD 2
m/h
m
kW
m/h
m
kW
4,680
11.1
13
4,310
13.6
13
4,350
8.8
22
4,040
10.8
21
4,080
7.5
29
3,820
9.3
28
3,850
6.5
37
3,630
8.2
36
HD 3
m/h
m
kW
m/h
m
kW
6,610
11.2
20
6,310
14.1
19
6,340
9.0
34
6,070
11.4
33
6,100
7.8
45
5,850
10.0
44
5,880
7.0
57
5,650
8.9
56
HD 4
m/h
m
kW
m/h
m
kW
13,350
15.7
33
12,530
19.4
32
12,610
12.4
57
11,900
15.3
56
11,980
10.7
78
11,360
13.2
76
11,430
9.3
102
10,890
11.6
99
System characteristics
Diagonal-blade fan
3-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED MIN
Technical data for MAX speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50C; air entry 18C
Dimensions for
Model sizes
design enclosures
Wall installation
HD 1
HD 2
HD 3
HD 4
1
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
642
642
852
54 58
77
63
738
738
975
76 83
79
65
866
866
1,076
103 114
84
70
1,026
1,026
1,236
159 175
89
75
M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
HD range with high-efficiency energy recuperation via a liquid-coupled system, together with the GEA RoofJETT.
For more details, please see the separate GEA MAXX Ergo documentation.
Ceiling installation
Model sizes
Max. air flow (m/h)
Heat-recovery efficiency
Ergo duty (kW)
HD 2
2,300
63%
36
HD 3
3,800
54%
52
HD 4
7,700
50%
65
Data for the Ergo duty: taken from separate GEA MAXX Ergo documentation
[16]
GEA MultiMAXX
HE range: heating
Model sizes
IP 54 wide-blade fan Duty (heating levels)
1
2
3
HE 1
Air flow for basic air outlet
m/h
2,470
2,470
2,470
Air-projection range for wall installation
m
8.2
8.2
8.2
Heating duty
kW
4
8
12
Air flow for profile-louver air outlet
m/h
2,200
2,200
2,200
Air-projection range for wall installation
m
8.8
8.8
8.8
Heating duty
kW
4
8
12
Air flow for secondary-air louver
m/h
2,180
2,180
2,180
Air-projection range for wall installation
m
9.5
9.5
9.5
Heating duty
kW
4
8
12
HE 2
Air flow for basic air outlet
m/h
3,980
3,980
3,980
Air-projection range for wall installation
m
9.3
9.3
9.3
Heating duty
kW
7
14
21
Air flow for profile-louver air outlet
m/h
3,560
3,560
3,560
Air-projection range for wall installation
m
10.0
10.0
10.0
Heating duty
kW
7
14
21
Air flow for secondary-air louver
m/h
3,520
3,520
3,520
Air-projection range for wall installation
m
10.8
10.8
10.8
Heating duty
kW
7
14
21
HE 4
m/h
m
kW
m/h
m
kW
m/h
m
kW
9,900
12.3
14
8,800
13.1
14
8,710
14.1
14
9,900
12.3
28
8,800
13.1
28
8,710
14.1
28
9,900
12.3
42
8,800
13.1
42
8,710
14.1
42
System characteristics
Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED
Technical data for MAX speed level
Heat exchanger: electric heating battery
Heating medium: 3-phase 400 V; operating range = -5C +40C
IP 42 enclosure-protection class (as per EN60529)
Dimensions for
Model sizes
industrial enclosures
Wall installation
HP 1
HP 2
HP 4
1
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
520
642
387
23 34
71
56
616
738
387
28 41
76
61
904
1,026
452
53 77
81
66
M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
[17]
GEA MultiMAXX
Model sizes
IP 54 wide-blade fan
Duty
1 2
HP 1
m3/h
m
kW
m3/h
m
kW
m3/h
m
kW
2,200
6.4
12
2,010
7.1
12
2,150
7.3
12
HP 2
3,620
7.5
20
3,280
8.3
19
3,520
7.5
20
HP 3
System characteristics
Wide-blade fan
2-speed motor; 3-phase 400 V; IP 54
Fan-speed ranges: MAX MED
Technical data for MAX speed level
Heat exchanger: Cu/Al
Heating medium: PWW 70/50C; air entry 18C
Dimensions for
Model sizes
industrial enclosures
Wall installation
HP 1
HP 2
HP 3
Max.
width
Max.
height
Max.
depth
Max.
weight
mm mm mm kg dB(A)
dB(A)
642
520
521
27 30
71
57
738
616
866
744
572
35 39
76
62
591
46 52
76
62
Selection of available air outlets for Prompt units on stock in the warehouse.
Wall basic
Wall profile
Ceiling basic
Ceiling profile
M easuring parameters for the sound pressure level (Lp): interval = 5 m; space volume = 1,500 m/h; reverberation time = 2 s; directional factor = 2
[18]
GEA MultiMAXX
Type B
Basic air-outlet louver
Model sizes
Type P
Profile air-outlet louver
Air outlets
Air-projection ranges
Wall version
V1
V2
V3
Type U
Secondary-air louver
V7
V8
V9
Air-projection range
m m m m m m m m m
Basic louver, 1-side
Profile louver
Secondary-air louver
Type B
Type P
Type U
Air-projection range
m m m m m m m m m
Basic louver, 1-side
Type B
Profile louver
Type P
Secondary-air louver
Type U
3
Air-projection range
m m m m m m m m m
Basic louver, 1-side
Type B
Profile louver
Type P
Secondary-air louver
Type U
4
Air-projection range
m m m m m m m m m
Air-projection range
m m m m m m m m m
Basic louver, 1-side
Profile louver
Secondary-air louver
Type B
Type P
Type U
The data on air-projection ranges applies to a warm-air flow that is 10 K above room temperature.
[19]
GEA MultiMAXX
Type Z
Basic air-outlet louver
Model sizes
Air outlets
Suspension heights
Ceiling version
Type P
Profile air-outlet louver
V1
V2
V3
Type C
Secondary-air louver
V7
V8
V9
Suspension height
m m m m m m m m m
Basic louver, 2-side
Profile louver
Secondary-air louver
Type Z
Type P
Type C
Suspension height
m m m m m m m m m
Basic louver, 2-side
Type Z
Profile louver
Type P
Secondary-air louver
Type C
3
Suspension height
m m m m m m m m m
Basic louver, 2-side
Type Z
Profile louver
Type P
Secondary-air louver
Type C
4
Suspension height
m m m m m m m m m
Suspension height
m m m m m m m m m
Basic louver, 2-side
Profile louver
Secondary-air louver
Type Z
Type P
Type C
The data on suspension heights applies to a warm-air flow that is 10 K above room temperature.
[20]
GEA MultiMAXX
Type L
Air-deflection louver
Model sizes
Type V
Air outlet unit, 4 sides
Air outlets
Suspension heights
Ceiling version
V1
V2
Type A
Air outlet nozzle, square
V3
Type T
Air outlet nozzle, rectangular
V7
V8
V9
Suspension height
m m m m m m m m m
Air-deflection louver
Outlet to 4 sides
Square nozzle
Rectangular nozzle
Type L
Type V
Type A
Type T
Suspension height
m m m m m m m m m
Air-deflection louver
Type L
Outlet to 4 sides
Type V
Square nozzle
Type A
Rectangular nozzle
Type T
3
Suspension height
m m m m m m m m m
Air-deflection louver
Type L
Outlet to 4 sides
Type V
Square nozzle
Type A
Rectangular nozzle
Type T
4
Suspension height
m m m m m m m m m
Air-deflection louver
Type L
Outlet to 4 sides
Type V
Square nozzle
Type A
Rectangular nozzle
Type T
Suspension height
m m m m m m m m m
Air-deflection louver
Outlet to 4 sides
Square nozzle
Rectangular nozzle
Type L
Type V
Type A
Type T
11.6
10.4 9.3 8.1 6.9 5.8 4.6 3.5 2.3
8.1 7.3 6.5 5.7 4.9 4.0 3.2 2.4 1.6
22.1 19.9 17.6 15.4 13.2 11.0 8.8 6.6 4.4
22.1 19.9 17.6 15.4 13.2 11.0 8.8 6.6 4.4
The data on suspension heights applies to a warm-air flow that is 10 K above room temperature.
[21]
GEA MultiMAXX
Air-intake modules
Mat-filter module
Bag-filter module
Mixed-air module
Rectangular duct
Duct bend
Spacer for
wall openings
Roof duct
[22]
[23]
www.gea-airtreatment.com