Professional Documents
Culture Documents
: Q19134-A / SA-13-0050
3.2
Date: 14-5-2013
min. 900 mm
max. 1750 mm
Project
Quotation nr.
Date
Type
1700 mm
Splash pattern diameter( 500 mm)=8200 mm
Oxygenation capacity,
standard conditions
38 kg O2/hr
:
:
:
:
:
:
18,7 kW
SS 304
Flender or equal
42 kW DIN
Spaans selection
30 kW
Interruption of the splash pattern (in height as well as in diameter) could have a negative impact in the oxygenation
capacity.
Suitable for ambient temperature between -20 and +55 degrees Celsius. Drive unit to be placed in well ventilated area
(>4m/s) and direct sunlight is to be avoided. Altitude above sea level < 1000m.
To ensurethe lifespan of the gearbox, starting method witha softstarter or frequency converter is recommended. DOL
starting might shorten lifespan of the drive-unit.
All above mentioned data are mean values and based onthe Spaans Babcock standard design and cannot be seen as
strictly binding. We reserve the rightto modify our technical specifications.