Ref.

: Q19134-A / SA-13-0050

3.2

Date: 14-5-2013

Sketch, pos. 010


: Al Hait
: SA-13-0050
: 14-mei-2013
:
170

min. 900 mm

max. 1750 mm

Project
Quotation nr.
Date
Type

1700 mm
Splash pattern diameter( 500 mm)=8200 mm

Oxygenation capacity,
standard conditions

38 kg O2/hr

Absorbed power (on the


motorterminals)
Material Impeller
GEARBOX
Power
E-MOTOR
Power

:
:
:
:
:
:

18,7 kW
SS 304
Flender or equal
42 kW DIN
Spaans selection
30 kW

Interruption of the splash pattern (in height as well as in diameter) could have a negative impact in the oxygenation
capacity.

Suitable for ambient temperature between -20 and +55 degrees Celsius. Drive unit to be placed in well ventilated area
(>4m/s) and direct sunlight is to be avoided. Altitude above sea level < 1000m.
To ensurethe lifespan of the gearbox, starting method witha softstarter or frequency converter is recommended. DOL
starting might shorten lifespan of the drive-unit.

All above mentioned data are mean values and based onthe Spaans Babcock standard design and cannot be seen as
strictly binding. We reserve the rightto modify our technical specifications.

Visit our website: www.spaansbabcock.com

You might also like