Precondition:
You have opened a project.
Options > Settings > Projects > "Project name" > Devices > Number using PLC
data
1. In the dialog Settings: Number using PLC data select a user-defined
scheme from the drop-down list, or create a new scheme using
(New).
EPLAN Training
4. In the Extent drop-down list, select the scope of numbering for the selected
group.
Note:
If you have selected the "Net" entry, then you can use the net extension to
increase the area affected by the numbering scheme, as described in the
section Defining Net Extensions.
EPLAN Training
EPLAN Training
8. If desired, you can change the sequence of the formatting elements using the
arrow buttons.
9. Click [OK].
The values entered will be saved in the selected scheme.
EPLAN Training
EPLAN Training
Typically a net ends at terminals, plugs, or connection points of functions. Use the net
extension function to expand the net with terminals and plugs. To do this, specify in
the net extension dialog which functions should not be treated as a boundary for the
net. This setting affects the designation if the range is selected as "Net".
Precondition:
You have opened a project.
Options > Settings > Projects > "Project name" > Devices > Number using PLC
data
1. In the dialog Settings: Number using PLC data select a user-defined
scheme from the drop-down list, or create a new scheme using
(New).
3. In the Net extension dialog use the arrow button to move the desired
functions from the Selection list into the Net extended with following
objects list.
The net will then no longer end at the selected functions, but rather it will be
extended by them.
EPLAN Training
4. Click [OK].
The setting will be saved in the selected scheme.
EPLAN Training
If the numbering should be continued after a function at which (based on the scope
configuration) the numbering would stop, then specify this at the function involved.
Precondition:
You have selected a function in the graphical editor.
Edit > Properties
1. In the Properties <...> dialog in the <Function category> tab, activate the
"Continue numbering with PLC data beyond this function" property
(Properties group box).
2. Click [OK].
When numbering with PLC data, those devices will also be numbered
which are connected to this function.
10
When numbering with PLC data, all devices connected to PLC connection points are
numbered by default if they are included in the scope. However, you can exclude
certain PLC connection points from the numbering.
Precondition:
You have selected a PLC connection point in the graphical editor.
Edit > Properties
1. In the Properties <...> dialog, in the PLC connection point tab, activate the
Prevent numbering with PLC data property.
2. Click [OK].
When numbering with PLC data, devices connected to this function will not
be numbered.
EPLAN Training
11
EPLAN Training
12
When numbering with PLC data, devices included in the scope of numbering are
numbered. General devices take the PLC data into their DT corresponding to the
settings; terminals and pins incorporate it into their designations.
Note:
When numbering with PLC data, only digital or analog inputs and outputs are taken
into account. Devices connected to general PLC connection points are not
numbered.
Preconditions:
In the graphical editor, PLC connection points are selected, or one or more
pages are selected in the page navigator on which PLC connection points are
located.
You have specified the scope and format of numbering.
EPLAN Training
13
3. Select the Mark as "Numbered using PLC data" check box so that functions
changed by numbering will be flagged.
During numbering, the "Numbered using PLC data" property will be set for
these functions.
4. Select the Preview of result check box to see a preview of the numbering
results before the new device tags / designations are adopted.
EPLAN Training
14
6. Click [OK].
The devices included in the scope of numbering will be numbered
according to the formatting settings and accept data from the PLC connection
point into the DT or designation.