When its necessary to equalize the fluid levels between the A and B hydraulic
reservoirs , you can use the procedures below.
Make sure the total quantity displayed on the gauge is approx 2/3 between refill and
FULL (classic) , or approx 92% on the DU (NG). This is to prevent overfilling and
fumes in the airco system , see maintenance tip 737-MT-12-002.
Hydraulic fluid transfer:
A>B
1.
2.
A pump
Park brake
ON
ON
3.
B pump
ON
4.
A pump
OFF
5.
6.
Park brake
OFF
7.
A pump
ON
8.
B pump
OFF
9.
Depress B sys
ON
2.
Reverse #1
DEPLOY
3.
OFF
4.
A pump
ON
5.
Reverse #1
STOW
6.
A pump
OFF
7.
Depress A syst.
8.
Make sure the REV light on the P5 OVHD panel extinguishes after T/R stow, else
reset.
Another easy method is almost similar, but transfers the fluid in small steps from B to
A:
In both cases A pump must be ON.
From A > B: 1-apply brakes, 2-b pump on, 3-release brakes, 4-b pump off, repeat as
required.
From B>A: 1-b pump on, 2-apply brakes, 3-b pump off, 4-release brakes, repeat as
required. When switching b pump, wait a moment (approx 2 sec.) with the next step,
so the system can switch from alt to norm or from norm to alt. This can be felt/heard
as a click on the brake pedals. Thanks to Virgil.