You are on page 1of 14

M2000 Platform Parameter

Check Guidence for Meditel RF


Team
Name

Xiang Wenjie 00244655

Version

1.0

Date

2015-04-19

Change History
Date

Date Revision

change Description

Author

Completed the draft.

Xiang Wenjie

version
2012-12-29

2015-04-19 1.0

00244655

M2000 Platform Parameter Check Guidence for Meditel


Contents
M2000 Platform Parameter Check Guidence for Meditel ........................................... 3
Using MML Commands to get Paras .................................................................. 5
1. LST ENODEBFUNCTIONincluding site name and eNodeBID, etc ............... 5
1.1Following the steps to get eNodeBID and Sitename on M2000 ................. 5
2. LST CELLCellid, Cellname, Localcellid, EARFCN, Band, Bandwidth, PCI,
Root sequence, etc ................................................................................................. 5
2.1 Following the steps to get Localcellid, Cellname and other important praras
on M2000 ....................................................................................................... 5
3. LST CNOPERATORTATAC ........................................................................ 6
3.1 Following the steps to get the sites TAC on M2000 ................................. 6
4. LST PDSCHCFGRS Power and PB ............................................................... 6
4.1 Following the steps to get the cells RS Power and PB on M2000 ............. 6
5. LST CELLDLPCPDSCHPAPA ..................................................................... 7
5.1 Following the steps to get the cells PA on M2000.................................... 7
5. LST CELLSELminimum required RX Level ................................................. 8
5.1 Following the steps to get the cells minimum required RX RSRP on M2000
........................................................................................................................... 8
6. LST RRCCONNSTATETIMERdifferent timer settings ................................. 8
6.1 Following the steps to get the sites Timer on M2000 .............................. 8
7.Neighbor related parametersExternal neighbor cells, intra-frequency neighbor
cells and inter-frequency neighbor cells ................................................................. 9
7.1 Following the steps to check cells external cell configuration on M2000 9
7.2 Following the steps to check cells intra-frequency cell configuration on
M2000 .......................................................................................................... 10
7.3 Following the steps to check cells inter-frequency cell configuration on
M2000 .......................................................................................................... 10
8.CSFB ParametersCSFB Algo Switch, UTRAN EARFCN ............................. 11
8.1 Following the steps to check sites CSFB Switch on M2000 ..................... 11
8.2 Following the steps to check sites CSFB Switch on M2000 ..................... 11

10.AlarmsCurrent alarms and History alarms ................................................... 12


10.1 Following the steps to check sites current alarms on M2000............... 12
10.2 Following the steps to check sites history alarms on M2000 ............... 12

M2000 Platform Parameter Check

Using MML Commands to get Paras


1. LST ENODEBFUNCTION including site name and
eNodeBID, etc
1.1Following the steps to get eNodeBID and Sitename on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST ENODEBFUNCTION
4.Result

2. LST CELL Cellid, Cellname, Localcellid, EARFCN,


Band, Bandwidth, PCI, Root sequence, etc
2.1 Following the steps to get Localcellid, Cellname and other important praras on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST CELL
4.Result

3. LST CNOPERATORTATAC
3.1 Following the steps to get the sites TAC on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST CNOPERATORTA
4.Result

4. LST PDSCHCFGRS Power and PB


4.1 Following the steps to get the cells RS Power and PB on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE

3.Input MML CommandLST PDSCHCFG


4.Result

5. LST CELLDLPCPDSCHPAPA
5.1 Following the steps to get the cells PA on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST CELLDLPCPDSCHPA
4.Result

5. LST CELLSELminimum required RX Level


5.1 Following the steps to get the cells minimum required RX RSRP on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST CELLSEL
4.Result

From the above figure, it shows that only RSRP>-128dbm, UE can access the LTE network.

6. LST RRCCONNSTATETIMERdifferent timer settings


6.1 Following the steps to get the sites Timer on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST CELLSEL
4.Result

7.Neighbor related parameters External neighbor cells,


intra-frequency neighbor cells and inter-frequency neighbor
cells
7.1 Following the steps to check cells external cell configuration on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST EUTRANEXTERNALCELL
4.Result

7.2 Following the steps to check cells intra-frequency cell configuration on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST EUTRANINTRAFREQNCELL
4.Result

7.3 Following the steps to check cells inter-frequency cell configuration on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST EUTRANINTERFREQNCELL
4.Result

8.CSFB ParametersCSFB Algo Switch, UTRAN EARFCN


8.1 Following the steps to check sites CSFB Switch on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST ENODEBALGOSWITCH
4.Result

8.2 Following the steps to check sites CSFB Switch on M2000


1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST UTRANNFREQ
4.Result

10.AlarmsCurrent alarms and History alarms


10.1 Following the steps to check sites current alarms on M2000
1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST ALMAF
4.Result

10.2 Following the steps to check sites history alarms on M2000


1.Login OMC
2.Login MML Window, Choosing a LTE NE
3.Input MML CommandLST ALMLOG
4.Result

We also can check the alarms like the following: