Professional Documents
Culture Documents
HW30HA-3
ELECTRICAL INPUT
HW COP Graph
COP
Voltage/Phase
380 - 415 Volts / 3 Phase / 50 Hz
Full Load Amps Per Phase
15.66 Amps
Min. Circuit Size
20 Amps
Refrigerant
R407C
Nominal Heating capacity
29.08 kW
Power input
6.02 kW
COP
4.83
Noise Level
69 dBa @ 3 m
Rated Load Amps @ 12C SST / 51C SCT
12.84 Amps
8
7
6
5
4
3
2
1
0
35
30
25
20
15
10
5
0
0
TECHNICAL DATA.
Compressor
Make
Type
Number Per Unit
FLA (Full Load Amps)
Voltage / Phase
Pole/RPM
Air Flow
Copeland
Scroll 20014
1
14.38 Amps
380 - 415 / 3
2/2,900
N/A
HW30HA-3
10
Fan
20
30
40
50
EBM-Papst
Axial
2
0.64 Amps (Each)
220 - 240 / 1
6/890
1600 L/s
COP
Power (kW)
Copper
Shell and Tube
1.16 L/s
61C
80 kPa
2,450 kPa
UNIT CLEARANCES
GENERAL INFORMATION
Water Connections
Drain
Minimum Ambient
Cabinet Construction
Approx. shipping weight
Size L x W x H
32mm Copper
20mm PVC
15C
1.2mm Stucco Aluminium
120 kg
1150mm x 565mm x 980mm
HW30HA-3
Direction
Description
1
2
3
4
5
Evaporator Coil
Water Connections
Plain Back
Compressor Access
Top Fan Discharge
1000mm**
500mm
Nil
850mm
3500mm
**When units placed side by side allow 2000mm clearance between evaporator coils.