You are on page 1of 3

MAINTENANCE REPORT

TITLE
REPORT BY
TECHNICIANS
PTW NUMBER
DATE COMPLETED

Promore Data At BOC Unable to Operate/Function


Asmawi Alias, Shahizam omar
Asmawi Alias, Shahizam omar
Work Order: 176356
Open issue

A. REPORT
Installation: Bunga Orkid Charlie (BOC)
Equipment: Down Hole Gauge (PROMORE DATA)
Manufacture: B&B Electronics
Model: PVB-IE-SND-M4-08M-N4
SN : PVB-696
Mfg date : Feb 2007
NEMA 4,12
CORE LABORATORIES LTD. PROMO DIVISION PVB-SERIES
CLASS1, DIV 2, GR C&D T4
10-30 VDC 2 AMPS MAX.
120-240AC 50-60HZ
240 WATTS-MAX 1PH
CERTTIED TO: CSA C22.2 NO 142 87 CEC (2006)
Summary of failures
Empty Screen at Display Panel. Supply checked 12.3 Vdc.
Missing Pi Data from BOC Downhole Gauge System.

B. FINDINGS
Suspected Optical Isolator/Repeater Data Card Faulty:

B.O.A Maintenance Department


Page 1

LED light For Data Transfer not illuminated (Red LED)


Suspected CPU/Memory Card Faulty/Empty:

Memory card Status only showing 0.6% From 8 Mb

No data captured & display showing nothing (no data) after performing
soft/hard reset. (After Perform Reset, Display Show DSP Booting Please
wait, then Showing System OK, and display panel go Blank (showing Nothing).

--Perform soft/Hard reset.

--display panel show system ok after reset.

B.O.A Maintenance Department

Page 2

-But there is no data show on display panel.

C. SUGGESTIONS AND RECOMMENDATIONS


Short term solution
To consult onshore support engineer or vendor for assistance.
Long term solution

D. PERSONNEL ON THE JOB


1) Asmawi Alias TML Operation E&I Technician
2) Shahizam Omar TML Operation E&I Technician

B.O.A Maintenance Department