Rancangan tangki penyimpanan 60 hari jika diketahui flow rate sebesar 40 Kgmol/jam n-hexana pa

tekanan atmospheris. Bahan kontruksi SA 265 grade C


Diket
Flow rate =
45 kgmol/jam
rho =
654.8 kg/m3
waktu =
1440 jam
bm =
86 kg/kmol
faktor koreksi =
20%
suhu simpan=
150 oF
Karakteristik
285 grade c
phi
3.14
Kapasitas
konversi

8510.6902871106 m3
300321.426062309 ft3

Faktor keselamatan
Total kapasitas
V (BBL)

10% 30032.1426
330353.56866854 ft3
58834.3974676352 bbl

Goal seek

h=
rho=
t=
tabel
t1
t2
t3
t4
t5
t6
t7

d/h
d
h

=/4 ^2

100
100
1
42.0832571552
0.6548 gr/ml
40.7920780865 lb/ft3
0.0001545154 (h-1)*D

0,000154515*(h-1)*D
42
36
30
24
18
12
6

karena tebal min 0,25 maka t6 = t7 = 0,25 in

=((1))/
144
=(.)/(4..)
+
didapat butt joint

r 40 Kgmol/jam n-hexana pada

13750
0.8

F= 13750
E= 0.8
x

cek volume

330353.569

0.6335133339 in
0.5408040655 in
0.4480947972 in
0.3553855288 in
0.2626762604 in
0.169966992 in
0.0772577236 in

karena tebal min 0,25 maka t6 = t7 = 0,25 in