You are on page 1of 8

BSW Replacement on DALIA FPSO.

Tag number: 33101A, 33101B, 34201A, 34201B, 35001

AT34201A
New Spare part.

Model Number
Reference Drawing
Flange Size
Probe length (Face to Face)
Serial Number
Kept on 3rd Deck.

OW302
OW302001-CD114( SHEET 1)
2 150 # RF
132 cm
3012361

Old Installed Analyzer

Model Number
Flange Size

Clearance is enough for new installation.


New support/ stand has been installed on site.

Connection Cable from Hockey Puck to Analyzer is missing.


Cable Glands are missing.
Power and signal cable can used old one.

OW202
2 150 (Adopted) from 3 150

AT34201B
New Spare part.

Model Number
Reference Drawing
Flange Size
Probe length (Face to Face)
Kept on Floor Deck.

OW302
OW302001-CD114( SHEET 1)
2 150 # RF
132 cm

Old Installed Analyzer.

Model Number
Flange Size

Clearance is enough for new installation.


New support/ stand has been installed on site.

Connection Cable from Hockey Puck to Analyzer is missing.


Cable Glands are missing.
Power and signal cable can used old one.

OW202
2 150 (Adopted) from 3 150

AT33101A
New Spare part.

Model Number
Reference Drawing
Flange Size
Probe length (Face to Face)
Serial Number
Kept on 3rd Deck.

OW302
OW302001-CD114( SHEET 2)
2 300 # RF
132 cm
*****************

Old Installed Analyzer

Model Number
Flange Size

Clearance is not much enough for new installation but can be installed.
New support/ stand is installed, but new transmitter need to remove.

Connection Cable from Hockey Puck to Analyzer is missing.


Cable Glands are missing.
Ball Valve 2 300 # RF full Bore required
Power and signal cable can used old one.

OW302
3 300 # RF

AT33101B
New Spare part.

Model Number
Reference Drawing
Flange Size
Probe length (Face to Face)
Serial Number
Kept on P52

OW302
OW302001-CD114( SHEET 2)
2 300 # RF
132 cm
**********************

Old Installed Analyzer

Model Number
Flange Size

Clearance is not much enough for new installation but can be installed.

OW202
3 300 # RF

New support/ stand is not installed on site

Connection Cable from Hockey Puck to Analyzer is missing.


Cable Glands are missing.
Ball Valve 2 300 # RF full Bore required
Power and signal cable can used old one.

You might also like