REFINERY PROCESSES
SAMPLER
Modelling and Optimization
John E. Edwards
Process Simulation Engineer, P & I Design Ltd
Refinery Processes
Section 2
Thermodynamics
Section 3
Crude Column
13
Section 4
Vacuum Still
23
Section 5
27
Section 6
Hydrotreater
43
Section 7
Catalytic Reformer
47
Section 8
Amine Treatment
53
Section 9
Miscellaneous Applications
57
Section 10
59
70
Preface
The process industry covers a broad spectrum of activities that involve the handling and treatment of
gases, liquids and solids over a wide range of physical and processing conditions. This manual provides
a comprehensive review of the fundamentals, definitions and engineering principles for the study of
processes encountered in hydrocarbon processing using steady state simulation techniques.
Applications are presented for a wide range of processing units involving design and operations.
Process simulations are carried out using CHEMCAD software by Chemstations, Inc. of Houston.
This manual has been developed with the full support of Chemstations simulation engineers based in
Houston.
The simulation of crude distillation at atmospheric pressure, vacuum distillation and sour gas amine
treatment is covered in Section 13 Process Measurement and Control of the book Chemical
Engineering in Practice by J.E.Edwards. This manual includes these topics and extends the study to
other refinery processes including splitters, stabilizers, hydrotreaters and reformers.
Thermodynamics are reviewed with special reference to the application of pseudocomponent curves
and crude oil databases
Each topic is in the form of a condensed refresher and provides useful practical information and data.
Each section is numbered uniquely for contents and references, with the nomenclature being section
specific. The references are not a comprehensive list and apologies for unintended omissions.
Reference is made to many classic texts, industry standards and manufacturers data. Information has
been mined from individual project reports and technical papers and contributions by specialists working
in the field.
.
The Author
http://uk.linkedin.com/pub/john-edwards/1b/374/924
John E.Edwards is the Process Simulation Specialist at P&I Design Ltd based in Teesside, UK.
In 1978 he formed P&I Design Ltd to provide a service to the Process and Instrumentation fields. He
has over fifty years experience gained whilst working in the process, instrumentation and control
system fields.
Acknowledgements
A special thanks to my colleagues at Chemstations, Houston, who have always given support in my
process simulation work and the preparation of the articles that make up this book:
N.Massey, Ming der Lu, S.Brown, D.Hill, A.Herrick, F.Justice and W.Schmidt of Germany
Also thanks to my associate P.Baines of Tekna Ltd for help with the organic chemistry topics.
Section 1
Refinery Processes
References
1.
2.
3.
4.
Shrieve, Chemical Process Industries, Chapter 37, 5 th Edition, McGraw Hill, 1984.
J.A.Moulijn, M.Makkee, A.Van Diepen, Chemical Process Technology, Wiley, 2001.
G.L.Kaes, Refinery Process Modelling, Athens Printing Company, 1st Edition, March 2000.
W.L.Nelson, Petroleum Refinery Engineering, 4th Edition, McGraw Hill, 1958.
Overview
Most refinery products are mixtures separated on the basis of boiling point ranges. The block diagram,
by API, shows overall relationship between the refining processes and refined products.
Refining is a mature, complex and highly integrated operation. Columns with a wide variety of internals
are used in many stages of the process. Fractional distillation under vacuum and pressure conditions is
used to separate components. Light ends are steam stripped and the heavy ends are vacuum distilled
at reduced the temperatures. Stabilizers are used to remove light ends, including LPG, to reduce the
vapor pressure for storage and subsequent processes. Absorbers and strippers are used to remove
unwanted components such as sulphur.
Simple distillation processes do not produce sufficient gasoline above the minimum required octane
number. This is achieved by converting heavy to light hydrocarbons using catalytic processes including
fluidic catalytic cracking (FCC), hydrotreating, hydrocracking, catalytic reforming and alkylation.
Crude petroleum consists of thousands of chemical species. The main species are hydrocarbons but
there can be significant amounts of compounds containing sulphur (0-6%), oxygen (0-3.5%) and
nitrogen (0-0.6%). The main groups are:
Descriptor
-ane
-ene
-ol
-one
Member
C2H6
ethane
C2H4
ethylene
C2H2
acetylene
C2H5OH ethyl alcohol
(CH3)2.CO acetone
>31.1 API
31.1 API to 22.3 API
22.3 API to 10 API
6
Extra-heavy
<10 API
Bitumen
Heavy or extra-heavy crude oils, as defined by the density ranges given, but with viscosities greater
than 10000 mPa.s measured at original temperature in the reservoir and atmospheric pressure, on a
gas-free basis
Natural Gas
Light hydrocarbon mixture that exists in the gaseous phase or in solution in crude oil in reservoirs but
are gaseous at atmospheric conditions. Natural gas may contain sulphur or other non-hydrocarbon
compounds.
Natural Gas Liquids
Hydrocarbon components recovered from natural gas as liquids including ethane, propane, butanes,
pentanes plus, condensate and small quantities of non- hydrocarbons.
Atmospheric and vacuum distillations produce the different fractions as detailed in the table below.
Temperature
<30C
Description
Gaseous
Hydrocarbon
Density
Composition
Applications
C3H8, C4H10
Gas fuel or
enrichment
Naptha
Benzene
0.65
0.72
0.76
0.8
C8H18, C9H20
C10H22,
C11H24
C12H26 to
C18H36
C5H12,
C6H14
C6H14,
C7H16
C8H18
Kerosene
General
Solvent
Solvent for
Home
solvent,
for oils,
oils, fats &
heating
aviation
fats &
varnishes
Jet fuel
spirit
varnishes
Gasoline, contains C6H14, C7H16, C8H18 40-180 C
>350 C
Heavy
oils
Residue
Asphalt
or
Bitumen
C18H38 to
C28H58
Diesel,
fuel oils
Roads,
Wax
paper
Further fractionation of the 70 to 150C cut is required to obtain the naptha and benzene cuts.
Vacuum distillation of the topped crude is required to obtain Light Vacuum Gas Oil (LGVO) and Heavy
Vacuum Gas Oil (HVGO)
When the difference in volatility between components is small a solvent of low volatility is added to
depress the volatility of one of the components. This process is known as extractive distillation. Butenes
are separated from butanes using this method with furfural as the extractant.
When a high volatility entrainer is used the process is known as azeotropic distillation. Anhydrous
alcohol is formed from 95% aqueous solution using benzene to free the azeotrope and high purity
toluene is separated using methyl ethyl ketone as the entrainer.
Typical Crude Oil Products Profile Ref EIA March 2004 Data
Product
Refined gallons/barrel (gal/bbl)
Gasoline
19.3
Distillate Fuel Oil (Inc. Home Heating and Diesel Fuel)
9.83
Kerosene Type Jet Fuel
4.24
Residual Fuel Oil
2.10
Petroleum Coke
2.10
Liquified Refinery Gases
1.89
Still Gas
1.81
Asphalt and Road Oil
1.13
Petrochemical Feed Supplies
0.97
Lubricants
0.46
Kerosene
0.21
Waxes
0.04
Aviation Fuel
0.04
Other Products
0.34
crude oil
dist
light gasses
Naptha (full range)
kerosenes
Diesels
Other high boilers
<30c
>30<200
>150<270
>180<315
Heavy Naptha
eg Mutineer (Aus)
Parafns
Napthenes
Aromatics
light naptha
heavy naptha
References
9
method 3
method 2
method 2
method 1
method 1
Catalytic cracking
and other methods
method 3
vol%
62
32
6
deg c
>35<145
>140<205
dist
RON 90STANDARD
10% n heptane
C7H16
straight chain hydrocarbon
90% iso octane
C8H18
branched chain hydrocarbon (ALSO KNOWN AS 2,2,4TRIMETHYL PENTANE)
Gasolines are compared to this mixture in relation to defagration performance under pressure in a test engine
Thermodynamics
C8H18
CH4
C6H6C2H5
2.5H2
C6H6
3H2
C8H18
C4H8
C8H18
C2H4
%vol?
50
technically 2,2,4trimethyl pentane
30
20
Iso octane
Methane
Ethyl Benzene
Benzene
Hydrogen
iso octane
Butene
iso octane
Ethene
Gasoline
(500components)
iso octane
Cyclopentane
Ethyl Benzene
Gasoline
Section 2
1. G.L.Kaes, Refinery Process Modelling, Athens Printing Company, 1st Edition, March 2000
2. American Society for Testing and Materials (ASTM International), Standards Library
Global K and H Models
The following table gives a summary of suitable K and H models for common refinery processes.
Refinery Processing Thermodynamic Models Summary
Process
K Model
H Model (Forced)
Crude Atmospheric Distillation
Grayson Streed
Lee Kessler
Vacuum Distillation
ESSO
Lee Kessler
Hydrotreater
SRK
SRK
Sour Gas Treatment
Amine
Amine
FCC Gas Treatment
Peng Robinson
Peng Robinson
Propylene Splitter
Peng Robinson
Peng Robinson
Compression
BWRS
BWRS
Grayson Streed K model is primarily applicable to systems of non-polar hydrocarbons. It is good for
modelling hydrocarbon units, depropanizers, debutanizers, or reformer systems. The approximate
range of applicability is as follows:
Temperature Range
0 to 800F
-18 to 430C
Pressure Range
< 3000 psia
< 20000 kPa
ESSO K model predicts K-values for heavy hydrocarbon materials at pressures below 100 psia. The
average error for pure hydrocarbons is 8% for p* > 1 mmHg, and 30% for p* between 10E-06 and 1
mmHg according to API Technical Data Book Vol 1. It is good for modelling vacuum towers.
Lee Kessler H model is good for hydrocarbon systems.
AMINE K model is based on the Kent Eisenberg method to model the reactions with diethanolamine
(DEA), monoethanolamine (MEA), methyl diethanolamine (MDEA) being included.
The chemical reactions in the CO2-Amine system are described by the following reactions:
RR'NH2+
RR'NCOO + H2O
CO2 + H2O
HCO3H2O
H+
RR'NH
HCO3CO3- H+
+ RR'NH
+ HCO3
+ H+
+ H+
+ OH-
Where R and R' represent alcohol groups. The reaction equations are solved simultaneously to obtain
the free concentration of CO2. The partial pressure of CO 2 is calculated by the Henry's constants and
free concentration in the liquid phase.
The AMINE K Model in CHEMCAD treats the absorption of CO 2 in aqueous MEA as a fast chemical
reaction, in other words, gas film controlled implying a very low stripping factor. However it is known that
this process is liquid film controlled since Henrys Law controls the diffusion of CO 2 into the liquid prior
to chemical reaction taking place.
10
Section 3
Crude Column
Case/File Name
R3.01
Desalted crude is preheated with the pump around and topped crude heat exchangers prior to being
heated to ~620F in the direct fired furnace. Above this temperature thermal decomposition (cracking)
will take place resulting in increased light ends and fouling of heat exchange surfaces due to carbon
based deposits. The following initial guidelines are suggested:
1.
2.
3.
For paraffin based crudes at moderate furnace temperatures, an estimated cracked gas rate of
5.0 SCF/bbl (42 gal/bbl) crude oil is reasonable.
For asphalt based crude oil a cracked gas production of 2.5 SCF/bbl crude oil is suggested.
The cracked gas may be given an arbitrary composition as follows:
50 mol% methane, 40 mole% ethane, and 10 mole% propane.
The feed to the atmospheric crude tower is a mixed vapor-liquid phase of ~0.4 vapor fraction. The
vapours flow upwards and are fractionated to yield the products.
Crude towers are typically 4m diameter, 2030m in height with 1530 trays.
11
A typical Process Flow Diagram for a crude unit, including pump-around circuits and side strippers, is
shown. The column is modelled on the basis of theoretical stages, as opposed to actual trays, so it is
necessary to apply tray efficiency to translate the actual trays NA to theoretical trays NT where
=NT/NA. Note that commercial simulators provide various tray efficiency models, which are not suitable
for crude distillation columns. Tray efficiency should be based on experience. The relationships
between NA and NT are indicated in the diagram.
The
liquid product sidestreams contain light hydrocarbons which must be removed to meet the initial boiling
point specification for the products. The liquid sidestreams are fed to strippers that use either a reboiler
or steam to strip out these light components which are returned to the crude tower. Current preference
is to use reboiled side strippers for the lower boiling products to reduce the heat load on the crude tower
condenser and the sour water stripper.
Side strippers are typically 1-2m diameter, 3m in height with 48 trays representing 23 theoretical
stages. Height limitations can be met by using structured packing which has high capacity and low
HETP values as compared to trays.
Pumparound cooling circuits provide reflux to remove the latent heat from hot flash zone vapors and
condense the side products. A pump-around zone may be considered equivalent to an equilibrium flash
where equilibrium liquid is recirculated. The large flow of pump-around liquid creates a region of
constant liquid composition that eliminates fractionation. The heat removed preheats the crude feed.
12
Section 4
Vacuum Still
Case/File Name
R4.01
Vacuum distillation is used to separate the high boiling bottoms from the crude column. The Vacuum
Unit process flow diagram is shown with distillation UnitOp 1 selected as Tower+.
13
14
Section 5
Splitting and Product Purification
Case/File Name
R5.01
R5.02
R5.03
R5.04
R5.05
R5.06
R5.07
1.
2.
3.
4.
References
H.Kister, Distillation Design, McGraw-Hill, ISBN 0-07-034909-6
G.L.Kaes, Refinery Process Modelling, Athens Printing Company, 1st Edition, March 2000
G.L.Kaes, Practical Guide to Steady State Modelling of Petroleum Processes
H.Kazemi Esfeh and I.Aalipour mohammadi, Simulation and Optimization of Deethanizer Tower,
2011 International Conference on Chemistry and Chemical Process, Singapore
Introduction
A primary activity in hydrocarbon processing involves the fractionation and purification
of light ends using columns, the most common being stabilizers, deethanizers,
debutanizers and depropanizers. A typical purification plant schematic is shown:
Deethanizer
The deethanizer removes ethane (C2H6) and lighter components which may be fed to
the olefines unit for production of ethylene (C 2H4) or polyethylene or polypropylene
products. Bottoms are fed to the debutanizer. Design for C 2 mole fraction or C 2/C3 mole
ratio in the bottoms.
Debutanizer
The debutanizer separates mixed LPG product (mostly C 3s and C4s) and a stabilized
condensate (C5+). Design for RVP in bottoms with 12 psia being typical and reflux ratio
0.5 1.0
Depropanizer
The depropanizer separates propane (C 3s) as overheads from the butane (C 4) to the
bottoms.
Stabilizer
Stabilizers are used to remove light ends (mainly C 4s) from condensate to meet Reed
Vapour Pressure (RVP) specification for future processing or to allow storage in floating
roof tanks. Design for RVP in bottoms with 12 psia being a typical maximum value
All purification units use the bottom tray or reboiler temperature and reflux for control.
The stabilizer uses bottom tray or reboiler temperature alone as there is no condenser
for reflux control. Using these parameters in process simulation allows predicted
product properties to be compared against actual process conditions. Simulation
15
16
Splitters are used extensively in hydrocarbon processing, including C 2s, C3s, C4s and Naphtha. The
process simulation methods used are similar to those for the purification process with the CHEMCAD
SCDS UnitOp being used.
Tray Column Industry Practice and Efficiencies (1)
Actual Trays
Overall Efficiency
25 - 35
70 - 75
110 - 130
95 - 100
200 - 250
95 - 100
70 - 80
85 - 90
Process
Naphtha Splitter
C2 Splitter
C3 Splitter
C4 Splitter
Theoretical Trays
18 - 25
105 - 125
190 - 240
60 - 68
17
the
on
the
18
Column Height
Column Diameter
Number of Trays
Weir Length (side)
Weir Length (centre)
Liquid Flowpath Length
Active Area
Downcomer Area (side)
m2
m
mm
m2
mm
mm
no/tray
%
0.86
0.6
39
0.922
51
2
772
18.82
SCDS simulation model is now changed to Tray Column Mass Transfer and the tray details are entered
as shown. Tray efficiency profiles were not entered but 85 to 90% is typical.
The side weir dimension is as shown in the
diagram below and is not to be confused with
weir length.
side
table
Area 0.43
0.335
1.859
2 Passes
in
19
Section 6
Hydrotreater
Case/File Name
R6.01
Hydrotreater Simulation
Description
Hydrotreater
References
1. J.A.Moulijn, M.Makkee, A.Van Diepen, Chemical Process Technology, Wiley, 2001.
2. G.L.Kaes, Refinery Process Modelling, Athens Printing Company, 1st Edition, March 2000.
3. W.L.Nelson, Petroleum Refinery Engineering, 4th Edition, McGraw Hill, 1958.
Process (1, 2)
Hydrotreaters are used to selectively remove undesirable elements and hydrogen saturate unsaturated
components. Reactor pressures vary 500-1000psig and temperatures 550-700F.
Hydroteating involves reaction with hydrogen to remove mainly sulfur, nitrogen and oxygen with some
hydrogenation of double bonds and aromatic rings taking place. Hydrotreating is always applied as a
pre-treatment to naphtha reforming to protect the catalyst against S-poisoning. Hydrotreating of heavy
residues is not considered here.
H2 reacts with mercaptans (1H2), thiophenes (3H2) and benzothiphenes (5H2) produce H2S
H2 reacts with pyridine (5H2) produces NH3
H2 reacts with phenols (1H2) produces H2O
Hydrotreater Hydrogen Usage and Losses (2)
Units
scf/barrel fresh
sm3/m3 fresh
Remarks
feed
Reactions(basis fresh feed
100 500
18 -89
Unsaturated components >H2
Solubility(basis fresh feed)
10 - 20
1.8 3.6
Purge
40 - 100
7.2 - 18
Depend H2 in makeup gas
Recycle
500 - 1500
89 - 267
Maintain H2/hydrocarbon ratio
The flow sheet is similar for all hydrotreating operations. The liquid feed stock is mixed with a hydrogenrich gas and preheated by exchange with the reactor effluent. The warm feed is brought to the desired
reaction temperature in a furnace and fed to the hydrotreating reactor. The reactor effluent is cooled
and the hydrogen-rich gas is separated from the liquid product. The separator liquid is sent to a
fractionator for removal of dissolved light hydrocarbon liquids and gases.
20
Case R6.01
Hydrotreater Unit
Simulation flowsheet
Simulation Parameters
Thermodynamics selection is K-SRK and L-SRK.
Pseudocomponents are created for the feed (FEEDC6 +) and product (PRODC6+) streams based on
predicted molecular weight, API gravity and normal boiling point.
21
Section 7
Catalytic Reformer
Case/File Name
R7.01
Reformer Simulation
Description
Catalytic Reformer
References
1. G.L.Kaes, Refinery Process Modelling, Athens Printing Company, 1st Edition, March 2000.
2. A.Askari et al, Simulation and Modelling of Catalytic Reforming Process, Petroleum & Coal ISSN
1337-7027.
Process Description
A traditional reforming process uses three fixed bed reactors in series. Endothermic dehydrogenation
reactions take place in the first two reactors requiring fired inter-heaters to raise the temperature for the
following reactor with hydrocracking reactions being significant in the final reactor.
Reforming catalysts are subject to poisoning by hydrogen sulphide and other sulfur compounds,
nitrogen, and oxygen which are removed from the naphtha by mild hydrotreating. The primary reformer
feed stock is virgin (uncracked) naphtha from the crude distillation process and other naphtha stocks of
suitable boiling point range are acceptable after hydrotreating.
The reactions do not occur evenly through the reactors so it is the convention in simulation work to
consider all the reaction taking place in the last reactor. Reactors 1 and 2 are set up for mass transfer
with the pressure drop being entered and the isothermal mode being used to set the outlet temperature.
Using the initial reactor inlet composition for the inter-furnace duty calculations does not result in
significant inaccuracies. The final reactor is set up in adiabatic mode with the kinetic reactions specified.
Pre-treated naphtha is combined with recycle gas with H2 composition in range 75 to 85 mole % and
preheated by exchange with the effluent from reactor 3. Typical reactor pressures and temperature
drops are shown:
Operating Data
Inlet temperature F
Inlet pressure
psia
Measures T (Typical) F
Recycle
MMSCFD
Catalyst Volume
ft3
Reactor 1
937
413
60 (90-130)
0.5-1% Naphtha Feed
274
Reactor 2
937
394
35 (40-60)
Reactor 3
937
394
25 (1) (10-20)
411
910
Note 1 Simulation temperature drop is much larger due to the example reactions considered
The temperature drops across the reactors are monitored to track catalyst activity.
Separator parameters
The separator feed is cooled to 90 - 100F using air and water coolers and the flash drum pressure was
run at 290 psia and with isentropic flash. The hydrogen rich gas stream is used in other refinery
operations and compressed and remainder recycled to the process where it combines with the naphtha
feed prior to the feed/effluent heat exchanger.
Operating Data
Temperature F
Pressure
psia
H2 Purity
Separator
100
290
0.79
22
Stabilizer parameters
The liquid is feed to the stabilizer to remove the light ends. Reformer stabilizers generally have 30 to 36
actual trays with overall tray efficiencies in the range 70 to 75%. The primary function is to strip the nbutane from the reformate product. The distillate is sent to a gas recovery plant and the column
bottoms product is stabilized reformate.
Operating Data
Number of stages
Feed tray
Feed temperature
F
Tray 1 temperature
F
Bottom temperature
F
Partial condenser pressure psia
Stabilizer
36
19
297
257
446 (Simulation 488)
239
To indicate the principles of configuring the catalytic reformer the following stoichiometric equations
have been used.
Paraffin
Naphthenes
Aromatics + 3H2
Hydrocracking of paraffin
Hydrocracking of naphthenes
Pseudocomponent groupings will include specific boiling ranges such as for C6 to C11 paraffins, C6 to
C11 naphthenes, benzene, toluene and C8 to C11 aromatics.
23
Thermodynamics selected:
K-Peng Robinson
H-Peng Robinson
24
Section 8
Amine Treatment
Case/File Name
R8.01
References
1. A.Kohl and R.Nielsen, Gas Purification, Gulf Publishing , 5th Edition, 1997
Process
Chemical absorption of CO2 and H2S with amines provides the most cost effective means of obtaining
high purity vapor from sour gases in a single step. The process is well established for refinery gas
sweetening which are carried out at high pressures. Several alkanolamines such as MEA
(monoethanolamine), DEA (diethanolamine) and MDEA (methylydiethanolamine) have been used, with
the selection being determined by the application.
The speciality amine aqueous solution strength can vary in the range 15 to 50% and can have a
significant effect on the process economics. Generic amines, such as MEA and DEA, are more
corrosive and strengths are limited to 30%. The higher the solution strength the liquid circulation
requirement is reduced. Steam consumption is highly dependent on this selection, with lower
concentrations requiring more steam. The boiling point for regeneration increases at higher MEA
concentrations which greatly increases the rate of corrosion of common metals. Also MEA tends to
degrade as the temperature rises, increasing the replacement expense and involving the removal of
degradation products.
MEA has a substantially higher vapor pressure than other amines and a water wash at the top of the
absorber can be used to minimize amine losses. The Lean Amine Feed temperature can have a
significant influence on the amine losses.
A typical gas sweetening flowsheet using amine solution is shown. It consists of an absorber in which
cooled lean solvent flows downward contacting with the upward flowing gas to be treated. The rich
liquid leaves the absorber at a higher temperature due to the heats of solution and reaction and is
preheated with stripper bottoms prior to being fed to the reboiled stripping column. The overhead
stripped gas is cooled to remove water vapor which is returned to the column to maintain the water
balance. If the gas stream to be treated contains condensable hydrocarbons the lean amine
temperature should be above the dew point temperature to prevent condensation of an immiscible
hydrocarbon liquid which will promote foaming in the absorber.
25
Section 9
Miscellaneous Application
Miscellaneous Application Simulations
Description
Biodiesel Blending
Case/File Name
R9.01
Biodiesel Blending
Diesel is blended with Methyl Ester (ME) during ship offloading. The diesel composition in the ester can
vary from 0 to 20%v/v and the product blend ester composition is in the range 5% to 15%v/v. The ship
discharge flow can vary from 800m3/h to 1000 m3/h at a maximum pressure of 10 barg.
The mass balance on the streams give:
DE
E
DE + E
VE
DS
DS + DE + E
VP
Where:
DE
E
VE
DS
VP
E
E DE
VE
We have:
DE
Rearranging gives:
Methyl Ester
%
100
80
VP
and
E 1 VE
VE
E
E DE DS
V P DS
1 VP VE
DE E
and
DS
VE
6.667
10.0
20.0
5.33
8.0
16.0
V P 1
Ship to Ester
Blend
Flow Ratio
0.176
0.111
0.053
0.231
0.143
0.067
A process control system would set the blender flow ratios by entering the ME blend (V E) and Final
Product blend (VP). The ME blend flow (E+D E) required for a wild Ship Discharge flow (D S) is
calculated. The flow ratio controller would manipulate the ME flow to achieve the desired ratio.
In the simulation the blend actual ME component standard liquid volume fraction and the product ME
standard liquid volume fraction are set in the appropriate controllers.
26
Fluid
Diesel
Methyl Ester !00%
Methyl Ester 80%
Viscosity
cps
2.78
7.48
5.72
The simulation results are in accordance with the theory developed above.
The
maximum and minimum ester blend flowrates obtained are 230.7 and 42.1 m 3/h.
27
Section 10
General Engineering Data
Contents
Units
Refinery Process Overview
Commercial Steel Pipe ANSI B36.10:1970 & BS 1600 Part 2: 1970
Typical Overall Heat Transfer Coefficients
Typical Fouling Resistance Coefficients
Heuristics for Process Equipment Design
Process Simulation Procedures and Convergence
References
1. Crane Co., Flow of Fluids Through Valves, Fittings and Pipes, Publication 410, 1988
Units
Volume
The basic measurement for crude oil liquid volume is referred to as a barrel (bbl). CHEMCAD unit
converter feature by selecting Fn f6 allows conversion between units as shown:
Gas Constant R
8.314 J/K-mol
1.986 Btu/R-lbmol
API gravity (API ) of petroleum liquids is determined from specific gravity (SG) at 60F:
The specific gravity of petroleum liquids can be derived from the API gravity:
28
Heavy oil with a specific gravity of 1.0 (density water at 60F) has an API gravity of:
Crude oil is often measured in metric tons (1000kg). The number of barrels per metric ton for a given
crude oil based on its API gravity is calculated from:
29
A metric ton of West Texas Intermediate 39.6 API would contain about 7.6 barrels.
Reid Vapor Pressure (RVP)
A measure of gasoline volatility being defined as the absolute vapor pressure exerted by a liquid at
100F(37.8 C) as determined by the test method ASTM-D-323. The test method applies to volatile
crude oil and volatile non-viscous petroleum liquids.
Cetane Index
Based on the density and distillation range ASTM D86 of a hydrocarbon using two methods ASTM D976
and D4737 (ISO 4264). Cetane index in some crude oil assays is often referred to as Cetane calcule,
while the cetane number is referred to as Cetane measure.
Aniline Point
Defined as the minimum temperature at which equal volumes of aniline and oil are miscible to give an
estimate of the content of aromatic compounds in the oil. The lower the aniline point, the greater is the
content of aromatic compounds.
VABP and MeABP
Petroleum fractions are cuts with specific boiling point ranges, API gravity and viscosity. Each cut can
be divided into narrow boiling fractions called pseudo-components where the average boiling point can
be estimated as either mid-boiling point or mid-percentage boiling point. The TBP curve is divided into
an arbitrary number of pseudo-components or narrow boiling cuts. Since the boiling range is small both
mid-points are close to each other and can be considered as the VABP or MeABP for that pseudocomponent.
Five different average boiling points can be estimated on the distillation curve. The volume average
boiling point (VABP) and the mean average boiling points (MeABP) are the most widely used.
VABP is calculated from the ASTM D86 distillation and is the average of the five boiling point
temperatures (F) at 10, 30, 50, 70 and 90% distilled:
MeABP (R) is used in the definition of the Watson K which is given by:
Factors Note 1
-12
10
10-9
10-6
10-3
10-2
10-1
101
102
103
106
109
1012
Prefix
pico
nano
micro
milli
centi
deci
deca
hecto
kilo
mega
giga
tera
E-12
E-09
E-06
E-03
E-02
E-01
E01
E02
E03
E06
E09
E12
30
Symbol
p
n
m
c
d
da
h
k
M Note 2
G
T
Note 1 Tip for setting power, make equal to number 0s so 0.00001 = 10 -5 and 100000 = 105
Note 2 Refinery industry practice sometimes uses MM to signify 10 6
31
d in
d in
d in
d mm
d mm
d mm
Air for combustion, unless otherwise stated, is at ISO conditions of 15C, 1.013 bar and 60% relative
humidity.
Air for compression is defined at Free Air Delivery(FAD) conditions of 20C, 1 bar and dry.
Pumps
Centrifugal pumps: single stage for 15-5000 gpm, 500 ft max head.
Centrifugal pumps: multistage for 20 11,000 gpm, 5500 ft max head.
Efficiency 45% at 100 gpm, 70% at 100 gpm and 80% at 10,000 gpm.
32
Feeds
Recycles
The chart below shows the basic steps involved in setting up a steady simulation.
It
is
recommended that the SCDS UnitOp is used for building fully integrated models because it has a
greater number of connection points.
SCDS 1 and SCDS 21-24 icons are the most developed having built in dynamic vessels and control
loops. However for our initial exercise we will use SCDS Column 1 icon.
For refinery operations the Tower UnitOp is more suitable as it includes pump around and stripping
facilities.
The stage numbering convention in CHEMCAD is from top to bottom, 1 to N. A stage is considered the
space above a plate. If a condenser is present it is stage 1; if a reboiler is present it is stage N. To
model a column which has ten stages plus condenser and reboiler 12 stages (10+condenser+reboiler =
12) must be specified.
If a condenser is present, the feed must not enter stage 1, as that is the reboiler. Top stage feeds should
enter stage 2, the top stage (plate), if a condenser is present. Likewise, if a reboiler is present a bottom
plate feed is connected to stage (N-1), not stage N.
Typically the user has a product specification, mass fraction of a key component in either the bottoms or
tops, for a column design or to achieve with an existing column.
Converging a column model in simulation is similar to converging a column in the real world; it is difficult
to go directly to high purity separation. It is best to start with an easy target, such as reflux ratio and
bottoms flowrate. Once the column is converged to this simple specification, we tighten the
specifications toward the target specification. Use the following procedure:
1.
2.
3.
4.
5.
6.
Generate TPxy and RCM plots to verify that the target is thermodynamically feasible with the
selected VLE K model.
On the SPECIFICATIONS page, set loose specifications such as Reflux Ratio and
Bottoms Flowrate or Reboiler Heat Input.
Run the column and converge. Change the specifications if necessary.
Go to the CONVERGENCE page of the column dialog. Set the initial flag to 0 Reload Column
Profile. This setting instructs CHEMCAD to use the current converged profile as its starting
point (initial conditions) in iterative calculations.
On the SPECIFICATIONS page change to more tight specifications. Run the column.
If the column converges, tighten the specifications and run again. If the column fails to converge, do not
save the profile of the failed attempt. Relax the specifications and run the column again.
Repeat from step 5 until you reach the target.
Often, it is difficult to obtain the first convergence on a column. If the column is run with no condenser or
reboiler, one does not have the option of loose specifications. If the column has a condenser or
reboiler, relaxing specifications does not always help.
1.
2.
3.
4.
5.
On the convergence page of the column dialog, specify estimates if you can make reasonable
estimates. Note that a bad guess will make the column more difficult to converge than no
estimate.
Remove non key components from the feed(s) to obtain the first convergence. Now set the
initial flag to 0 Reload Column Profile, return the other components, and run the unit again.
Specify a larger number of iterations on the convergence page of the column dialog. The
default is 50, but possibly 52 iterations will find the answer.
Try an alternate column model. If you are currently using the SCDS try the same separation
with a TOWER or vice versa. The two models use different mathematical models; often one will
find an answer in 10 iterations while the other is difficult to converge. It is not possible to obtain
different answers with the columns; the models are numerical methods to find a stable
composition profile.
Consider a partial condenser. If you have a condenser present but have a significant amount of
light ends, you may have difficulty converging the column. The default condenser type, total,
requires that no vapor leaves stage 1. If light ends are present, this may not be possible without
cryogenic temperatures. Changing condenser mode to partial allows the light ends gases to slip
past the condenser.
34