Professional Documents
Culture Documents
Brookfield Viscometer Factor Finder
Brookfield Viscometer Factor Finder
in
Viscosity
measurement
LABORATORY INSTRUMENT
CALIBRATION & CERTIFICATION
Annual service program for your Brookfield
Viscometer which includes replacement of parts
as necessary and cleaning of the sensing system
to guarantee long life and good performance.
Program includes an updated Certificate of
Calibration. Rush 24-hour and 48-hour service
available as well as loan instruments.
TEMPERATURE CONTROL
SYSTEMS
Brookfield TC series digital
baths/circulators and coolers with
range capability -20C to 200C.
Brookfield Thermosel System for
measurement of small samples to
300C.
PRACTICAL COURSE ON
VISCOSITY MEASUREMENTS
A single day course which covers such topics as the
principle of viscometer operation, calibration,
rheology, methodology and data interpretation.
Classes available at major metropolitan areas
throughout the United States and at our plant.
Customer on-site classes may also be arranged.
FACTOR FINDER
VISCOMETER
TORQUE RANGE
SPEED-RPM
SPINDLE
NUMBER*
FACTOR
INSTRUCTIONS
This Factor Finder applies to Brookfield Dial Reading
Viscometers. Torque ranges include LV, RV, HA and HB with
standard spindles. Insert slide in sleeve so appropriate torque/
spindle selection is visible in window.
To convert Viscometer dial readings to centipoise (mPas),
adjust slide until Viscometer torque range and spindle number
being used appear in window. Multiply reading noted on
Viscometer dial (0-100 scale) by factor shown beside speed at
which measurement is being made. Turn slide over for HA/
HB factors.
Dial Reading x Factor = Viscosity in Centipoise (mPas)
Example: LVT with #61 spindle at 6 rpm
Dial Reading: 75
Factor: 10
75 x 10 = 750 centipoise (mPas)
Full scale viscosity range for any speed and spindle combination is the maximum viscosity that can be measured. Calculate
as shown.
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Blvd., Middleboro, MA 02346-1031 USA
T: 508-946-6200 or 800-628-6139
F: 508-946-6262
W: www.brookfieldengineering.com
K = 1000
*LV spindles may be marked as
either 1, 2, 3, 4 (for use with Dial
Viscometers) or 61, 62, 63, 64
(for use with Digital Viscometers)
Factor: 10
RV
RV
RV
RV
RV
RV
RV
01
02
03
04
05
06
07
LV
LV
LV
LV
1 or 61 2 or 62 3 or 63 4 or 64
.5
200
.5
800
.5
2K
.5
4K
.5
8K
.5
20K
.5
80K
100
400
1K
2K
4K
10K
50
200
500
1K
2K
5K
2.5
40
2.5
160
20
100
400
2K
25
100
250
500
1K
2.5K
10K
10
50
200
1K
20
80
200
400
800
2K
8K
12
12
25
12
100
12
500
2.5 400
2.5 800
2.5 1.6K
2.5 4K
.3
200
40K
.6
100
20K
1.5 40
2.5 16K
.3
1K
.6
500
1.5 200
.3
4K
.6
2K
1.5 800
.3
20K
.6
10K
1.5 4K
10
10
10
40
10
100
10
200
10
400
10
1K
10
4K
30
30
10
30
40
30
200
20
20
20
20
50
20
100
20
200
20
500
20
2K
60
60
60
20
60
100
50
50
50
20
50
40
50
80
50
200
50
800
100 1
100
100 10
100 20
100 40
100 100
100 400
HA
H01
.5
1
2
2.5
5
10
20
50
100
400
200
100
80
40
20
10
4
2
HA
H02
.5
1
2
2.5
5
10
20
50
100
1.6K
800
400
320
160
80
40
16
8
HA
03
.5
1
2
2.5
5
10
20
50
100
HA
04
4K
.5
2K
1
1K
2
800 2.5
400
5
200 10
100 20
40
50
20
100
8K
4K
2K
1.6K
800
400
200
80
40
HA
05
.5
1
2
2.5
5
10
20
50
100
16K
8K
4K
3.2K
1.6K
800
400
160
80
HA
06
.5
1
2
2.5
5
10
20
50
100
HA
07
40K .5
20K 1
10K 2
8K
2.5
4K
5
2K
10
1K
20
400 50
200 100
160K
80K
40K
32K
16K
8K
4K
1.6K
800
HB
H01
HB
H02
.5
1
2
2.5
5
10
20
50
100
.5
1
2
2.5
5
10
20
50
100
1.6K
800
400
320
160
80
40
16
8
6.4K
3.2K
1.6K
1.28K
640
320
160
64
32
HB
03
.5
1
2
2.5
5
10
20
50
100
16K
8K
4K
3.2K
1.6K
800
400
160
80
HB
04
.5
1
2
2.5
5
10
20
50
100
32K
16K
8K
6.4K
3.2K
1.6K
800
320
160
HB
05
.5
1
2
2.5
5
10
20
50
100
64K
32K
16K
12.8K
6.4K
3.2K
1.6K
640
320
HB
06
.5
1
2
2.5
5
10
20
50
100
HB
07
160K .5
80K 1
40K 2
32K 2.5
16K 5
8K 10
4K 20
1.6K 50
800 100
640K
320K
160K
128K
64K
32K
16K
6.4K
3.2K