You are on page 1of 2

Datasheet

USI 16
M i d g e t F u s e Te r m i n a l s

Weidmuller offers DIN rail mounted terminal


blocks for the popular 13/32 x 1 midget fuses.
Compact and touch safe, these terminals meet
CSA, UL and IEC requirements.

NEW

Features:
CSA certified for 600V, 30A max.
UL rated 600V, 30A max.
(terminals without indication only)
1, 2, 3, and 4 pole versions available
metal foot for secure mounting on
35mm DIN rail
only 17.5mm wide per pole
lever mechanism for quick and safe fuse
replacement
vented housing to reduce internal heating
and extend fuse life
optional fuse failure indication available

United States

Canada

Mexico

Weidmuller Inc.

Weidmuller Ltd.

Weidmuller, S.A. de C.V.

821 Southlake Blvd.

10 Spy Court

5 Sur No. 4311

Richmond, Virginia 23236

Markham, Ontario L3R 5H6

Col. Huexotitla

Telephone: (800) 849-9343

Telephone: (800) 268-4080

72534 Puebla, Pue. Mexico

Facsimile: (804) 379-2593

Facsimile: (905) 475-2798

Telephone: (22) 37 2549

Email: info@weidmuller.com

Email: info1@weidmuller.ca

Facsimile: (22) 43 1981

Website: www.weidmuller.com

Website: www.weidmuller.ca

Email: weidmull@acnet.net

USI 16
Specifications:
Dimensions (LxWxH)
Moulding material
Wire Size
Mounting
Rating

86mm x 17.5mm x 66mm


polyamide, UL94 -V2
18 - 6 AWG
TS35 (35mm) DIN rail
CSA 600V 30A
UL 600V 30A max.
13
/32 x 1 midget fuses, including CC types

Fuse Size

NOTE: Disconnect fuse terminals are NOT designed to be operated under load

Ordering Data:
Catalog Numbers

without indication

with LED indication*

1
2
3
4

991073
991074
991075
991076

991077
991078
991079
991080

pole
pole
pole
pole

with neon indication


for 120-600V
990975
991627
991770
-

* Indicator is flashing LED which illuminates if the fuse blows. A unique feature of the indicator circuitry is that under some circumstances it is possible to get a fuse failure indication even when the load is disconnected. This is accomplished by capacitively coupling the indicator signal to the system neutral or, in the case of 3 phase circuits, to another phase. The rate of flash of the
indicator is proportional to the line voltage and whether the load is connected or not. Typical flash rates and indicator current
draws are as follows:
120Vac, load
load
220Vac, load
load

connected:
open:
connected:
open:

50A,
10A,
125A,
20A,

100 per minute


20 per minute
150 per minute
40 per minute

The indicator is optimised for 220Vac operation and may be dim at other voltages. An alternative would be Weidmullers VM8
voltage monitor (consult factory for details.)

Dimensional drawing:

71mm

80mm

66mm

60mm
44mm

64mm
40mm

68mm to bottom of rail

45mm

17.5mm
DIN rail 35x7.3mm
80mm
86mm max

Subject to technical changes Printed in Canada 99990088 06/2001