You are on page 1of 16

Datasheet

ACT20M
Signal Isolation and Conversion

NEW
Weidmullers new 8-pole housing, module power can
be distributed through the rail for minimized power
wiring and reduced installation costs. This Power Rail
provides the flexibility to add or remove individual
modules quickly and easily without affecting the wiring
or operation of other components on the rail.
The ACT20M range offers D.C. and temperature isolators
and converters for use in industrial and marine applications.
Configuration is simple because the ACT20M modules
require no calibration. Models with selectable temperature,
voltage and current ranges feature DIP switches. For the
Universal input model, Weidmuller provides vendorindependent, FDT-based configuration software available
for download from the Weidmuller website.

High quality signal isolation and conversion in a


slim 6mm wide housing format is now available with
Weidmullers ACT20M range. Features include
worldwide approvals for both standard and hazardous
area installations. This series of single- and dual-channel
models extends Weidmullers signal conditioning
portfolio with a package of solutions for industrial
process measurement and control applications.
ACT20M is designed to reduce the time and cost
of building control panels. DIN-rail mounted in

Weidmuller, Canada
10 Spy Court
Markham, Ontario L3R 5H6
Telephone: (800) 268-4080
Facsimile: (877) 300-5635
Email: info1@weidmuller.ca
Website: www.weidmuller.ca

Weidmuller, Mexico
Blvd. Hermanos Serdn 698,
Col. San Rafael Oriente
Puebla, Puebla, Mexico
C.P. 72029
Telephone: 01 222 2686267
Facsimile: 01 222 2686219
Email: clientes@weidmuller.com.mx
Website: www.weidmuller.com.mx

Features:
Very high density analog signal isolation
and conversion
Easy installation with Power Rail cross-connect option
DIP switches for calibration-free re-ranging
Universal input model uses FDT configuration software
(and CBX200 interface)
CE, cULus, cFMus Class 1 Div. 2 and Class 1 Zone 2
ATEX, IECEx Zone 2, DNV, GL approvals
Ambient temperature range typically -13F to 158F
(-25C to 70C)

Weidmuller, United States


821 Southlake Blvd.
Richmond, Virginia 23236
Telephone: (800) 849-9343
Facsimile: (804) 379-2593
Email: info@weidmuller.com
Website: www.weidmuller.com

ACT20M Signal Isolation and Conversion

Universal input converter

ACT20M-UI-AO-S

Isolating and converting of


temperature signals and DC signals
Configuration using FDT/DTM
software
Optional power supply via the DIN-railbus
3 way isolation

4
3
I, U, R
IN

I, U

OUT

1
82

83

Supply

Supply

Technical data
Input
Sensor

Thermocouples: B, E, J, K, L, LR, N, R, S, T, U, W3, W5


RTD: PT100, PT1000, Ni120, Ni100, Ni1000
2/3/4 wire
10 10 k
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
> 10 M
< 150
> 15 V DC at 20 mA

Potentiometer/Resistance
Input current
Input voltage
Input resistance, voltage
Input resistance, current input
Sensor supply
Output
Output current
Output voltage
Load resistance, current
Load resistance, voltage
General data
Supply voltage
Power consumption

0(4)20 mA
0(2)10 V
< 600
> 10 k

Temperature coefficient
Insulation coordination
Insulation voltage
Rated voltage
Pollution degree
Overvoltage category
Approvals
Dimensions
Length x width x height
Clamping range (nominal / min. / max.)
Note

mm
mm2

5
U, I,

6
U, I

2
Power

In

7
8

5
U, I,

6
U, I

2
Power

7
8

Out 1

Power
24 V

PLC
mA
passive

Out 1

PLC
mA
passive
Power
24 V

ACT20M-UI-AO-S
+
4-wire
V
active

4
3

In

5
U, I,

6
U, I

2.5 kV
300 V
2
II

cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone


2, DNV, GL

Power

TC
In

114.3 x 6.1 x 112.5


2.5 / 0.5 / 2.5

7
8

Type
ACT20M-UI-AO-S

Qty.
1

Part No.
1176030000

Note

Accessories
Marker
USB interface

In

5
U, I,

6
U, I

2
Power

7
8

Out 1

Power
24 V

PLC
mA
passive

Out 1

PLC
mA
passive
Power
24 V

ACT20M-UI-AO-S

Ordering data

Note

4-wire
mA
active

2-wire
mA
passive

24 V DC 30 %
0.4 W (24 V supply / Passive input / 20 mA input &
output / 100 load)
-25 C+70 C
-40 C+85 C
< 0.1 % span (DC, RTD)
< 0.2 % + CJ error (TC)
< 0.01 % /K

Ambient temperature (operational)


Storage temperature
Accuracy

ACT20M-UI-AO-S
4

Type
MF 5/7.5 MC NEUTRAL
CBX200 USB

Qty.

DIN-rail bus, refer to accessories page

Part No.
1877680000
8978580000

RTD

Sense +

R+

Sense

5
U, I,

6
U, I
Power

7
8

Out 1

PLC
mA
passive
Power
24 V

ACT20M Signal Isolation and Conversion

Signal splitter

ACT20M-CI-2CO-S

ACT20M-AI-2AO-S

Isolating, converting and splitting


DC signals
Configured using DIP switch
Optional power supply via the
DIN-rail bus
4 way isolation

I IN

I OUT 2

2
1

7
82

83

I OUT 1

Supply

I, U
IN

I, U
OUT 2

2
1

Supply

7
82

83

I, U
OUT 1
Supply

Supply

Technical data
Input
Input current
Input voltage

0(4)20 mA

0(4)20 mA
0(2)10 V
0(1)5 V
< 75
> 500 k
> 17 V DC at 20 mA

Input resistance, current input


Load resistance, voltage
Sensor supply
Output
Output current
Output voltage

< 75

Load resistance, current


Load resistance, voltage
General data
Supply voltage
Power consumption

< 300 / channel


10 k

0(4)20 mA
0(2)10 V
0(1)5 V
< 300 / channel
> 10k / channel

24 V DC 30 %

24 V DC 30 %

0.4 W (24 V supply / Passive input / 20 mA input &


output / 100 load)

0.4W (24 V supply / Passive input / 20 mA input &


output / 100 load)

Ambient temperature (operational)


Storage temperature
Accuracy
Temperature coefficient
Cut-off-frequency
Insulation coordination
Insulation voltage
Rated voltage
Pollution degree
Overvoltage category
Approvals

-25 C+70 C
-40 C+85 C
< 0.05 % of measurement range
< 0.01 % /K
100 Hz

-25 C+70 C
-40 C+85 C
< 0.05 % of measurement range
< 0.01 % /K
100 Hz

2.5 kV
300 V
2
II

2.5 kV
300 V
2
II

cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone


2, DNV, GL

cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone


2, DNV, GL

114.3 x 6.1 x 112.5


2.5 / 0.5 / 2.5

114.3 x 6.1 x 112.5


2.5 / 0.5 / 2.5

Dimensions
Length x width x height
Clamping range (nominal / min. / max.)

0(4)20 mA

mm
mm2

Note

Ordering data
Note

Accessories
Marker
Note

Type
ACT20M-CI-2CO-S

Qty.
1

Part No.
1175990000

Type
ACT20M-AI-2AO-S

Qty.
1

Part No.
1176020000

Type
MF 5/7.5 MC NEUTRAL

Qty.

Part No.
1877680000

Type
MF 5/7.5 MC NEUTRAL

Qty.

Part No.
1877680000

DIN-rail bus, refer to accessories page

DIN-rail bus, refer to accessories page

ACT20M Signal Isolation and Conversion

Converters for DC mA
and Volts

ACT20M-AI-AO-S

ACT20M-AI-AO-E-S

Isolating and converting DC signals


DIP switch for range changes
without re-calibration
Optional power supply via the
DIN-rail-bus
3 way isolation
Choice of active or passive mA input
(E model is not hazardous
location approved)
4

I, U
IN

I, U
OUT

2
82

83

Supply

82

Supply

I, U
OUT

I, U
IN

83

Supply

Supply

Technical data
Input
Input current
Input voltage
Input resistance, current input
Input resistance, voltage
Sensor supply
Output
Output current
Output voltage
Load resistance, current
Load resistance, voltage
General data
Supply voltage
Power consumption

0(4)20 mA
0(2)10 V; 0(1)5 V
< 75
> 500 k

0(4)20 mA
0(2)10 V; 0(1)5 V
<Input
600
> 10 k

0(4)20 mA
0(2)10 V; 0(1)5 V
<Input
600
> 10 k

Switch

1
2
3
4

0 V20DC
mA 30 %
24

4 20
0.4
W m(24 V supply / Passive
input
/ 20mA input
&

0 10 V/ 100 load)
output

2 C+70
10 V
-25
C

0 C+85
5V
-40
C

5 V % of measurement range
<10.05

... 20 mA
loop
<00.01
% /K

4 ... 20
100
HzmA loop

Ambient temperature (operational)


Storage temperature
Accuracy
Temperature coefficient
Cut-off-frequency
Insulation coordination
Insulation voltage
Rated voltage
Pollution degree
Overvoltage category
Approvals
Dimensions
Length x width x height
Clamping range (nominal / min. / max.)

0(4)20 mA
0(2)10 V; 0(1)5 V
< 75
> 500 k
> 17 V DC at 20 mA

mm
mm2

2.5 kV
Switch
300
V1
Output
2
5
6
7
II

0 20 mA
ATEX
zone
cULus
cFMus Div.2,
2, IECEx Zone
4 2061010-1,
m

2,0 DNV,
10 VGL

2 10 V

114.3
0 5 Vx 6.1 x 112.5

2.5
1 5/ 0.5
V / 2.5

1
2
3
4

0 20 mA
24 V DC 30 %

4 20 m
0.4 W (24 V supply / Passive
input
/ 20mA input
&

0 10 V
output / 100 load)

2 10 V
0 C+70 C

05V
-40 C+85 C

1 5 V
< 0.2 % of measurement range

0 ... 20 mA loop
< 0.015 % /K

4 ... 20 mA loop
100 Hz
2.5 kV
Output
300
V1
2
5
II

0 20 mA

4 20 m
cULus
DNV, GL
0 10 61010-1,
V

2 10 V

0 5 Vx 6.1 x 112.5
114.3

1 5/ 0.5
V / 2.5
2.5

ACT20M-AI-AO-S

In

4
3

U, I
U, I
Power

4-wire
V, mA
active

7
8

5
6

U, I

Marker
Note

In

Type
ACT20M-AI-AO-S 2

Accessories

ACT20M-AI-AO-E-S
5

Ordering data

Switch

= on
= off

= on
= off

2-wire
mA
passive

Switch

Type
MF 5/7.5 MC NEUTRAL

U, I
Power

Qty.
71
8

Qty.

DIN-rail bus, refer to accessories page

Out 1

Power
24 V

PLC
V, mA
passive

Out 1

PLC
V, mA
passive

4-wire
V, mA
active

In

4
3

5
6

U, I
U, I

2
1

Power

7
8

Out 1

PLC
V, mA
passive
Power
24 V

Part No.
1176000000
Power

Type
ACT20M-AI-AO-E-S

Qty.
1

Part No.
1176010000

Part No.
1877680000

Type
MF 5/7.5 MC NEUTRAL

Qty.

Part No.
1877680000

24 V

DIN-rail bus, refer to accessories page

ACT20M Signal Isolation and Conversion

ILP and OLP isolators

ACT20M-CI-CO-ILP-S

ACT20M-CI-CO-OLP-S

Isolation of DC mA signals
Takes power from the input loop (ILP)
or output loop (OLP)
Available as either single-channel or
double-channel version
2 way isolation

I IN 1

I IN 2

I OUT 1

I IN 1

I OUT 2

I IN 2

I OUT 1

I OUT 2

Technical data
Input
Input current
Input resistance, current input
Output
Output current
Load resistance, current
General data
Power consumption
Ambient temperature (operational)
Storage temperature
Accuracy
Temperature coefficient
Cut-off-frequency
Insulation coordination
Insulation voltage
Rated voltage
Pollution degree
Overvoltage category
Approvals
Dimensions
Length x width x height
Clamping range (nominal / min. / max.)

0(4)20 mA
< 65 at 25 C

0(4)20 mA
typ. < 125

0(4)20 mA
< 600

4 - 20 mA
< 600

30 mW per channel - from input loop


-25 C+70 C
-40 C+85 C
< 0.1 % of measurement range
< 0.01 % /K
100 Hz

55 mW per channel - from output loop


-25 C+70 C
-40 C+85 C
< 0.1 % of measurement range
< 0.01 % /K
100 Hz

2.5 kV
300 V
2
II

2.5 kV
300 V
2
II

ACT20M-CI-CO-ILP-S

4-wire
cULus
61010-1,+
mA
In

2, DNV,
active GL

mm
mm2

4
cFMus
3

5
PLC
Div.2, ATEX zone
+ 2, IECEx Zone
6

Out

mA
passive

114.3 x 6.1 x 112.5


2.5 / 0.5 / 2.5 1

ACT20M-CI-CO-OLP-S

4
5
2-wire
PLC
cULus
61010-1,+ cFMus
Div.2, ATEX zone
+ 2, IECEx Zone
mA
mA
In
Out
2, DNV,
3
passiveGL
active
6
I
2
114.3 x 6.1 x 112.5
1
2.5 / 0.5 / 2.5

ACT20M-2CI-2CO-ILP-S
4-wire
mA
active

In 1

4-wire
mA
active

In 2

4
3
2

6
7

ACT20M-2CI-2CO-OLP-S
5

7
I

Out 1

Out 2

PLC
mA
passive

2-wire
mA
passive

In 1

PLC
mA
passive

2-wire
mA
passive

In 2

4
3
2

5
I
I

Out 1

PLC
mA
active

Out 2

PLC
mA
active

Ordering data
Single-channel version
Double-channel version

Type
ACT20M CI-CO-ILP-S
ACT20M 2CI-2CO-ILP-S

Qty.
1
1

Part No.
1176070000
1176080000

Type
ACT20M- CI-CO-OLP-S
ACT20M-2CI-2CO-OLP-S

Qty.
1
1

Part No.
1176040000
1176050000

Marker

Type
MF 5/7.5 MC NEUTRAL

Qty.

Part No.
1877680000

Type
MF 5/7.5 MC NEUTRAL

Qty.

Part No.
1877680000

Accessories

ACT20M Signal Isolation and Conversion

DC isolator

ACT20M-CI-CO-S

Isolating DC signals
Optional power supply via the
DIN-rail-bus
3 way isolation

I IN

I OUT

1
82

83

Supply

Supply

Technical data
Input
Input current
Load resistance, current input
Output
Output current
Load resistance, current
General data
Supply voltage
Power consumption

0(4)20 mA
< 75
0(4)20 mA
< 600

2.5 kV
300 V
2
II
cULus 61010-1, cFMus Div.2, ATEX zone 2, IECEx Zone
2, DNV, GL
mm
mm2

114.3 x 6.1 x 112.5 mm


2.5 / 0.5 / 2.5 mm

Note

Ordering data
Type
ACT20M-CI-CO-S

Qty.
1

Part No.
1175980000

Type
MF 5/7.5 MC NEUTRAL

Qty.

Part No.
1877680000

Note

Accessories
Marker
Note

In

4
3

5
6

I
I

24 V DC 30 %
0.4 W (24 V supply / Passive input / 20 mA input &
output / 100 load)
-25 C+70 C
-40 C+85 C
< 0.05 % of measurement range
< 0.01 % span/K
100 Hz

Ambient temperature (operational)


Storage temperature
Accuracy
Temperature coefficient
Cut-off-frequency
Insulation coordination
Insulation voltage
Rated voltage
Pollution degree
Overvoltage category
Approvals

Dimensions
Length x width x height
Clamping range (nominal / min. / max.)

ACT20M-CI-CO-S
4-wire
mA
active

DIN-rail bus, refer to accessories page

Power

7
8

Out 1

PLC
mA
passive
Power
24 V

ACT20M Signal Isolation and Conversion

Temperature transmitter

ACT20M-RTCI-CO-OLP-S

ACT20M-RTI-CO-EOLP-S

Choice of isolating or non-isolating


converters for J or K thermocouples
and RTDs.
Hundreds of min/max range
combinations
Configuration via DIP switches
Power supplied from the output loop
2-way isolation (OLP-S model only)
Output is linear with temperature

+
PT 100
TC

+
Optional
external
CJC

8 V DC...35 V DC

PLC

PT 100

2
1

8 V DC...35 V DC

PLC

2
1

Technical data
Input
Sensor
Input measurement range

Temperature input range


Output
Output current
Load Resistance
Wire break detection
General data
Configuration
Supply voltage
Power consumption
Accuracy

Temperature coefficient
Galvanic isolation
Step response time
Ambient temperature (operational)
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height

mm
mm

PT100 / 2-/3-/4-wire, Thermocouple acc. to IEC 584,


type: J, Thermocouple acc. to IEC 584, type: K
PT100 -200+850 C, Thermocouple type J -100
+1200 C, Thermocouple type K -200+1370 C
(internal or external CJC)
Selectable by DIP Switch

PT100 / 2-/3-/4-wire

4...20 mA, 204 mA


<600
3.5 mA 23 mA none Selectable by DIP Switch

4...20 mA, 204 mA


<600
3.5 mA 23 mA none Selectable by DIP Switch

DIP switch
8...35 V DC Loop powered
ca. 1 W
absolute accuracy: < 0.05 % of the measurement
range, RTD (PT100) Basic accuracy: < 0.1 C of the
measurement range, TC (J,K) Basic accuracy: < 0.5
C of the measurement range
RTD (PT100) 0.01 % of the measurement rangeC
or 0.02 CC, TC (J,K) 0.1 CC
2-way isolator
30 ms / 300 ms Selectable by DIP Switch
-25...+70 C

DIP switch
8...35 V DC Loop powered
ca. 1 W
absolute accuracy: < 0.1 % of the measurement
range, Basic accuracy: < 0.2 C of the measurement
range

2.5 kVeff
300 Veff

N/A

2
II

2
II

cULus; FMEX; IECEXKEM; KEMAATEX;


DETNORVER; GL

cULus; FMEX; IECEXKEM; KEMAATEX;


DETNORVER; GL

2.5 / 0.5 / 2.5


114.3 / 6.1 / 112.5

2.5 / 0.5 / 2.5


114.3 / 6.1 / 112.5

PT100 -200+850 C

Selectable by DIP Switch

RTD (PT100) 0.01 % of the measurement rangeC


or 0.02 CC
Without isolation
30 ms / 300 ms Selectable by DIP Switch
-25...+70 C

Note

Ordering data
Type
ACT20M-RTCI-CO-OLP-S

Qty.
1

Part No.
1435590000

Type
ACT20M-RTI-CO-EOLP-S

Qty.
1

Part No.
1435610000

Note

ACT20M Signal Isolation and Conversion

Temperature transmitter

ACT20M-RTI-AO-S

ACT20M-RTI-AO-E-S

Choice of isolating or non-isolating


converters for RTDs.
Hundreds of min/max range
combinations
Optional Power Rail accessory
simplifies jumpering and saves
wiring time.
Configuration via DIP switches
3-way isolation (AO-S model only)

PT 100

82 83

I, V
PLC

PT 100
Supply

I, V
OUT 1

Supply

Supply

Technical data
Input
Sensor
Input measurement range
Temperature input range
Output
Output current
Output voltage
load impedance current
load impedance voltage
Wire break detection
General data
Configuration
Supply voltage
Power consumption
Accuracy

Galvanic isolation
Temperature coefficient
Step response time
Ambient temperature (operational)
Insulation coordination
Insulation voltage

PT100 / 2-/3-/4-wire
PT100 -200+850 C
Selectable by DIP Switch

PT100 / 2-/3-/4-wire
PT100 -200+850 C
Selectable by DIP Switch

0...20 mA, 4...20 mA Selectable by DIP Switch


0(1)...5 V, 0(2)...10 V Selectable by DIP Switch
600
10 k
3.5 mA 23 mA none Selectable by DIP Switch

0...20 mA, 4...20 mA Selectable by DIP Switch


0(1)...5 V, 0(2)...10 V Selectable by DIP Switch
600
10 k
3.5 mA 23 mA none Selectable by DIP Switch

DIP switch
24 V DC 30 %
1W
absolute accuracy: < 0.05 % of the measurement
range, Basic accuracy: < 0.1 % of the measurement
range
3-way isolator
0.01 % of the measurement range C or 0.02 C C
30 ms / 300 ms Selectable by DIP Switch
-25...+70 C

DIP switch
24 V DC 30 %
1W
absolute accuracy: < 0.1 % of the measurement
range

2.5 kVeff

N/A
N/A

Without isolation
0.01 % of the measurement range C or 0.02 C C
30 ms / 300 ms Selectable by DIP Switch
-25...+70 C

Rated voltage

300 Veff

Pollution severity
Surge voltage category
Approvals

2
II

2
II

cULus; FMEX; IECEXKEM; KEMAATEX;


DETNORVER; GL

cULus; FMEX; IECEXKEM; KEMAATEX;


DETNORVER; GL

2.5 / 0.5 / 2.5


114.3 / 6.1 / 112.5

2.5 / 0.5 / 2.5


114.3 / 6.1 / 112.5

Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height

mm
mm

Note

Ordering data
Type
ACT20M-RTI-AO-S
Note

Qty.
1

Part No.
1375510000

Type
ACT20M-RTI-AO-E-S

Qty.
1

Part No.
1375520000

ACT20M Signal Isolation and Conversion

Temperature transmitter

ACT20M-TCI-AO-S

ACT20M-TCI-AO-E-S

Choice of isolating or non-isolating


converters for J or K thermocouples
Hundreds of min/max range
combinations
Optional Power Rail accessory
simplifies jumpering and saves
wiring time.
Configuration via DIP switches
3-way isolation (AO-S model only)

+
TC
+
Optional
external
CJC

82 83

I, V

+
PLC

TC
+
Supply

Optional
external
CJC

I, V
OUT

Supply

Supply

Technical data
Input
Sensor
Input measurement range
Temperature input range
Output
Output current
Output voltage
load impedance current
load impedance voltage
Wire break detection
General data
Configuration
Supply voltage
Power consumption
Accuracy

Galvanic isolation
Temperature coefficient
Step response time
Ambient temperature (operational)
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals

Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height

mm
mm

Thermocouple (Type J, K)
Thermocouple type J -100+1200 C, Thermocouple
type K -200+1370 C (internal or external CJC)
Selectable by DIP Switch

Thermocouple (Type J, K)
Thermocouple type J -100+1200 C, Thermocouple
type K -200+1370 C (internal or external CJC)
Selectable by DIP Switch

0...20 mA, 4...20 mA Selectable by DIP Switch


0(1)...5 V, 0(2)...10 V Selectable by DIP Switch
600
10 k
3.5 mA 23 mA none Selectable by DIP Switch

0...20 mA, 4...20 mA Selectable by DIP Switch


0(1)...5 V, 0(2)...10 V Selectable by DIP Switch
600
10 k
3.5 mA 23 mA none Selectable by DIP Switch

DIP switch
24 V DC 30 %
ca. 1 W
absolute accuracy: < 0.05 % of the measurement
range, TC (J,K) Basic accuracy: < 0.5 C of the
measurement range
3-way isolator
< 0.1 % / C
30 ms / 300 ms Selectable by DIP Switch
-25...+70 C

DIP switch
24 V DC 30 %
ca. 1 W
absolute accuracy: < 0.1 % of the measurement
range, Basic accuracy: < 1 C

2.5 kVeff
300 Veff
2
II

N/A
N/A
2
II

cULus; FMEX; IECEXKEM; KEMAATEX;


DETNORVER; GL

cULus; FMEX; IECEXKEM; KEMAATEX;


DETNORVER; GL

2.5 / 0.5 / 2.5


114.3 / 6.1 / 112.5

2.5 / 0.5 / 2.5


114.3 / 6.1 / 112.5

Without isolation
0.01 % / C
30 ms / 300 ms Selectable by DIP Switch
-25...+70 C

Note

Ordering data
Type
ACT20M-TCI-AO-S

Qty.
1

Part No.
1375480000

Type
ACT20M-TCI-AO-E-S

Qty.
1

Part No.
1375500000

Note

ACT20M Signal Isolation and Conversion

Bipolar converters

ACT20M-BAI-AO-S

ACT20M-BAI-2AO-S

For use with center-zero sensors,


e.g. actuator position control, or
bi-directional flow monitoring.
DIP switches simplify configuration
Conversion choices: bipolar in/unipolar
out, or bipolar in/2x unipolar out.
Optional Power Rail accessory simplifies
jumpering and saves wiring time.

I, V
IN

82 83

I, V
OUT 1

I, V
IN

OUT 2

Supply

I, V

Supply

7
82 83

I, V
OUT 1

Supply

Supply

Technical data
Input
Input current
Input voltage
Input resistance, voltage
Input resistance, current inputs
Output
Cut-off frequency (-3 dB)
load impedance voltage
Number of outputs
load impedance current
Output voltage, note
Output current
General data
Accuracy
Configuration
Galvanic isolation
Mounting rail
Power consumption
Power consumption, max.
Step response time
Supply voltage
Temperature coefficient
Type of connection
Insulation coordination
EMC standards
Galvanic isolation
Insulation voltage
Pollution severity
Rated voltage
Standards
Surge voltage category
Approvals
Approvals
ROHS
Dimensions
Depth x width x height (mm)

-10 mA0+10 mA, -20 mA0+20 mA


-5 V0+5 V, -10 V0+10 V
Selectable by DIP Switch
1 M
50 at 20 mA

-10 mA0+10 mA, -20 mA0+20 mA


-5 V0+5 V, -10 V0+10 V
Selectable by DIP Switch
1M
50 at 20 mA

100 Hz, 10 Hz Selectable by DIP Switch


10 k
1
600
0(2)...10 V, 0(1)...5 V Selectable by DIP Switch
0...20 mA, 4...20 mA Selectable by DIP Switch

100 Hz, 10 Hz Selectable by DIP Switch


10 k
2
2 x 300
0(2)...10 V, 0(1)...5 V Selectable by DIP Switch
0...20 mA, 4...20 mA Selectable by DIP Switch

< 0.05 % of measuring range


DIP switch
3-way isolator;
TS 35
Typ. 400 mW
0.8W
7 ms, 100 ms, Selectable by DIP Switch
24 V DC 30 %
< 0.01% of span/C (TU)
Screw connection

< 0.05 % of measuring range


DIP switch
4-way isolator;
TS 35
Typ. 400 mW
0.8W
7 ms, 100 ms, Selectable by DIP Switch
24 V DC 30 %
< 0.01% of span/C (TU)
Screw connection

EN 61326-1
3-way isolator;
2.5 kVeff

EN 61326-1
4-way isolator;
2.5 kVeff

2
300 Veff

2
300 Veff

DIN EN 61010-1, DIN EN 60079


II

DIN EN 61010-1, DIN EN 60079


II

cULus, DNV, FM, IECEx, Ex


Conform

cULus, DNV, FM, IECEx, Ex


Conform

114.3 x 6.1 x 112.5

114.3 x 6.1 x 112.5

Note

Ordering data
Note

10

Type
ACT20M-BAI-AO-S

Qty.
1

Part No.
1375450000

Type
ACT20M-BAI-2AO-S

Qty.
1

Part No.
1375470000

ACT20M Signal Isolation and Conversion

Rail bus accessories


CH20M BUS-PROFIL TS35x7.5/1000

CH20M BUS-PROFIL TS35x15/1000

CH20M BUS 4.50/05 AU/1000

Support section for TS35 x 7.5


Length: 250, 500 or 750 mm

Support section for TS35 x 15


Length: 250, 500 or 750 mm

Bus PCB for use on TS35 x 7.5 and TS 35 x 15


Length: 250, 500 or 750 mm
Five conductor paths, gold plated
Electrical rating: 63 V AC, 5 A/conductor path

Support section for bus PCB

Ordering data

Type
CH20M BUS-PROFIL
TS35x7.5/250
CH20M BUS-PROFIL
TS35x7.5/500
CH20M BUS-PROFIL
TS35x7.5/750

Qty.

Part No.

10 1248150000
10 1248160000
5 1248170000

Support section for bus PCB

Ordering data

Type
CH20M BUS-PROFIL
TS35x15/250
CH20M BUS-PROFIL
TS35x15/500
CH20M BUS-PROFIL
TS35x15/750

Qty.

Part No.

1248180000

1248190000

1248210000

Bus PCB

Ordering data

Type
CH20M BUS 4.50/
05 AU/250
CH20M BUS 4.50/
05 AU/500
CH20M BUS 4.50/
05 AU/750

Qty.

Part No.

10

1248220000

10

1248230000

1248240000

CH20M BUS-ADP TS35/1000

CH20M BUS-AP LI TS35x7.5 & 15

CH20M BUS-AP RE TS35x7.5 & 15

Cover plate for rail bus


Length: 250, 500 or 750 mm

End plate for rail bus


Fits on TS35 x 7.5 and TS 35 x 15
Left

End plate for rail bus


Fits on TS35 x 7.5 and TS 35 x 15
Right

Cover plate

Ordering data
Type

Qty.

End plate

Part No.

CH20M BUS-ADP TS35/250

10 1248250000

CH20M BUS-ADP TS35/500

10 1248260000

CH20M BUS-ADP TS35/750

5 1248270000

Ordering data

Type
CH20M BUS-AP LI TS35x7.5
& 15

Ordering data
Qty.

Part No.

50

1193160000

SET CH20M BUS 250MM TS 35X15

SET CH20M BUS 250MM TS 35X7.5

S
 ET consists of one each of

S
 ET consists of one each of

Set

CH20M BUS 4.50/05 AU/250

CH20M BUS-ADP TS 35/250

CH20M BUS-ADP TS 35/250

CH20M BUS-AP LI TS 35X7.5 & 15

CH20M BUS-AP LI TS 35X7.5 & 15

CH20M BUS-AP RE TS 35X7.5 & 15

CH20M BUS-AP RE TS 35X7.5 & 15

CH20M BUS-PROFIL TS 35X15/250

CH20M BUS-PROFIL TS 35X7.5/250

Type
Qty.
SET CH20M BUS 250MM TS
1
35X15

Part No.
1335150000

Type
CH20M BUS-AP RE
TS35x7.5 & 15

Qty.

Part No.

50

1193170000

Set

CH20M BUS 4.50/05 AU/250

Ordering data

End plate

Ordering data

Type
Qty.
SET CH20M BUS 250MM TS
1
35X7.5

Part No.
1335140000

11

ACT20M Signal Isolation and Conversion

Output-current loop-powered
Galvanic isolation
Very low power consumption
Input range selected via DIP switch
No calibration necessary

OLP
UL Class I, Div. 2

U/I
I

Technical data
Input
Input voltage
Input resistance, voltage/current
Input current
Rated current
Output
Output current
Output signal limit
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Ambient temperature
Default setting
Accuracy
Temperature coefficient
Step response time
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage

Setting options/switch position


0...5V: 210 k; 0...10V: 430 k / 51
0(4)...20 mA
40 mA
4...20 mA (current loop)
Approx. 31 mA
/ RL = (UB-12 V) / 20 mA z.B. 600 at 24 V
10 Hz/ 100 Hz switchable
DIP switch
min. 12 V DC/ max. 30 V DC
0 C...+55 C
0...20mA, 10 Hz
0.2% of measuring range final value
150 ppm/K
< 10 Hz: 80 ms; 100 Hz: 50 ms
CE; cULus

n
0 20 mA

4 20 mA

05V
0 10 V
n
Transmission frequency
10 Hz
n
100 Hz
n

mm
mm

24V DC

24 V DC

230 V AC

1
3

WAVE ANALOGUE
OLP

8543720000/8543730000

Sensor

Part No.
8543720000

7
8
9
4 ... 20mA

0...10V

Ordering data
Screw connection

230 V AC

Qty.
1

SW 1
3

= on
= off

2.5 / 0.5 / 2.5


92.4 / 17.5 / 112.4

Type
WAS5 OLP

Example of application

III
2
5.5 mm

Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note

12

DIN EN 50178, DIN EN 61000-4-2


EN 55011, EN 61000-6
300 V
4 kV
4 kVeff / 5 s

Surge voltage category


Pollution severity
Clearance & creepage distances

Note

Input

RL

SPS

ACT20M Signal Isolation and Conversion

Thermal converter type:


K,J,T,E,N,R,S,B

PRO Thermo
Select of
thermocoupler
SW1
Typ
1
2
3

UL Class I, Div. 2

3-way isolation
Internal cold-junction compensation
Power supply can be cross-connected
using plug-in jumpers
Suitable for insulated and uninsulated
thermocouples
W AVETOOL software helps with
configuration, download at
www.weidmuller.com

K
J
T
E
N
R
S
B

U/I

Selection of
temperature span
SW2
Span 1 2 3 4 5

VC

Technical data
Input
Sensor
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
Offset current / Offset voltage
Line resistance in measuring circuit
Wire break detection
Fine adjustment
Status indicator

Thermo element (IEC 584) type: K,J,T,E,N,R,S,B


-200...+1820 C
0...10 V / 0(4)...20 mA
1 k / 600
max. 100 A / max. 0.05 V
50
LED flashing (output value: > 20 mA, >10 V)
5% (switchable)
Module active: LED on/ wire breakage: LED flashing/
Error: LED off

General data
Configuration
Supply voltage
Power consumption
Step response time
Current-carrying capacity of cross-connect.
Ambient temperature
Storage temperature
Default setting

DIP switch
24 V DC 25 %
800...850...950 mW at IOUT = 20 mA
without filter: max. 1.4 s; with filter: max. 7.5 s
2A
0 C...+55 C
-20 C...+85 C
Type K; 0...1000C; 4...20mA; filter: off; man.
calibration: off
CE; cULusEX; GL

Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage

DIN EN 50178, DIN EN 61000-4-2


EN 55011, EN 61000-6
300
4 kV
2 kVeff / 5 s

Surge voltage category


Pollution severity
Clearance & creepage distances

mm
mm

2.5 / 0.5 / 2.5


92.4 / 17.5 / 112.4

Ordering data
Screw connection

Type
WAS5 PRO Thermo

Qty.
1

100 C
150 C
200 C
250 C
300 C
350 C
400 C
450 C
500 C
550 C
600 C
650 C
700 C
750 C
800 C
850 C
900 C
950 C
1000 C
1050 C
1100 C
1150 C
1200 C
1250 C
1300 C
1350 C
1400 C
1450 C
1500 C
1600 C
1700 C
1800 C

Accuracy

III
2
3 mm

Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note

Note

Part No.
8560720000

K -200 C -150 C
-150 C 1200 C
1200 C 1372 C
J -200 C -150 C
-150 C 1200 C
T -200 C -150 C
-150 C 400 C
E -200 C -150 C
-150 C 1000 C
N -200 C -150 C
-150 C 1300 C
R -50 C 200 C
200 C 1760 C
S -50 C 200 C
200 C 1760 C
B 50 C 250 C
250 C 500 C
500 C 1820 C

Selection of minimum
temperature
SW1
min
1 2 3 4
0 C
10 C
20 C
30 C
40 C
50 C
100 C
150 C
200 C
+ 50 C
+ 100 C
+ 150 C
+ 200 C
+ 250 C
+ 500 C
Special range

Selection of output
Switch 2
Output
6
7

0 ... 10 V

0 ... 20 V

4 ... 20 V
Switching on the
manual fine adjustment
SW 2
man.
adjust.
6

off

on
Switching on the
filter function
SW 2
Filter
off
on

= on
= off

(5K + 0.1 % of set range)


(3K + 0.1 % of set range)
(4K + 0.1 % of set range)
(4K + 0.1 % of set range)
(3K + 0.1 % of set range)
(5K + 0.1 % of set range)
(3K + 0.1 % of set range)
(4K + 0.1 % of set range)
(3K + 0.1 % of set range)
(6K + 0.1 % of set range)
(3K + 0.1 % of set range)
(10K + 0.1 % of set range)
(6K + 0.1 % of set range)
(10K + 0.1 % of set range)
(6K + 0.1 % of set range)
(25K + 0.1 % of set range)
(10K + 0.1 % of set range)
(6K + 0.1 % of set range)

13

ACT20M Signal Isolation and Conversion

RTD signal isolator/converter

Universally adjustable via DIP switch


3-way isolation
Linearisation
Power supply can be cross-connected
using plug-in jumpers
W AVETOOL software helps with
configuration,download at
www.weidmuller.com

RTD
J,R

PRO RTD
UL Class I, Div. 2

U/I

VC

Technical data
Input
Sensor

PT100/2-/3-/4-wire, Ni100/2-/3-/4-wire, potentiometer: min. 0100 , max. 0100 k,


Resistance: 0450
configurable

Temperature input range


Output
Output current / Output voltage
Offset current / Offset voltage
Load impedance, voltage/current
Wire break detection
Fine adjustment

0(4)...20 mA / 0...10 V
max. 100 A / max. 0.05 V
1 k / 600
LED flashing (output value: > 20 mA, >10 V)
5 %, Version 1 and later: 12.5 % /
potentiometer: 12.5%...25%
Module active: LED on/ wire breakage: LED flashing/
Error: LED off

Status indicator
General data
Configuration
Supply voltage
Power consumption
Step response time

DIP switch, Potentiometer


24 V DC 25 %
830...880...980mW at IOUT = 20 mA
fast/slow: 2-/3-/4-conductor: 1.2 s/2.2 s;
potentiometer: 0.5 s/1.1 s
0 C...+55 C
CE; cULus; GL

Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage

DIN EN 50178, DIN EN 61000-4-2


EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s

Surge voltage category


Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note

III
2
3 mm
mm
mm

2.5 / 0.5 / 2.5


92.4 / 17.5 / 112.4

Ordering data
Screw connection
Note

14

Type
WAS5 PRO RTD

Qty.
1

Part No.
8560700000

ACT20M Signal Isolation and Conversion


PRO RTD
Switch position / setting options

Choice of inputs
Switch 1
Input
1
2
3
PT100 2-wire

PT100 3-wire

PT100 4-wire

R
2-wire

NI100 2-wire

NI100 3-wire

NI100 4-wire

Potentiometer

= on
= off

Choice of outputs
Switch 2
Output
6
7
0...10 V

0...5 V

0...20 mA

4...20 mA

Choice of step
response time
Step response time
slow
fast

min

0 C
-10 C
-20 C
-25 C
-30 C
-40 C
-50 C
-60 C
-70 C
-80 C
-90 C
-100 C
-150 C
-200 C

Choice of minimum input size


Switch 1
Rmin
Potimin
4
5
6
0
0%

10
10 %

20
20 %

20
25 %

30
30 %

40
40 %

50
50 %

60
60 %

70
70 %

80
80 %

90

100

150

200

Special area

T
40 K
50 K
60 K
70 K
80 K
90 K
100 K
110 K
120 K
125 K
130 K
140 K
150 K
160 K
170 K
180 K
190 K
200 K
250 K
300 K
350 K
400 K
450 K
500 K
550 K
600 K
650 K
700 K
750 K
800 K
850 K
900 K

Choice of measuring range


Switch 2
Poti
R
1 2 3 4
20
20 %

25
25 %

30
30 %

35
35 %

40
40 %

45
45 %

50
50 %

55
55 %

60
60 %

62,5 62,5 %

65
65 %

70
70 %

75
75 %

80
80 %

85
85 %

90
90 %

95
95 %

100 100 %

125
--
150
--
175
--
200
--
225
--
250
--
275
--
300
--
325
--
350
--
375
--
400
--
425
--
450
--

Switch on the manual fine


adjustments
S. 1
Man. adjustment
8
off

on

S. 2
8

Accuracy, slow/fast step response time


PT 100,Ni 100: 0,3 % from measuring range 0,8 %
from measuring range < 100 K / 0,3 K / 0,8 K
Potentiometer: 0.2 % from end value / 0.3 %
Resistance: 0.2 % from end value / 0.3 %

Temperature coefficient
Measuring range 200 K
100 K Measuring range < 200 K
40 K Measuring range < 100 K

200 ppm / C
250 ppm / C
400 ppm / C

Adjustment example for zero and span


Temperature adjustment:
Output
420 mA
DIP switch
-10 C+110 C
Span
75110 C
Range
120 C
Adjustment range
12.5 %

Zero
25 C
10 C

95 C
110 C
125 C

5 C
Span
5 C

110 C
125 C
140 C

Wavetool adjustment tool


This service tool enables quick and
straightforward configuration of the
WAVEANALOG PRO.
Internet download:
http://www.weidmuller.com

15

ACT20M Signal Isolation and Conversion

ACT20 power feed module

ACT20M-FEED-IN-PRO-S

ACT20-FEED-IN-BASIC-S

Distributes the voltage supply on the


busbar
Compatible with Weidmullers CH20
rail bus
Optional backup supply connection
Approved for installation in Ex Zone 2
/Div. 2
Monitors the supply voltage
Alarm alerts via the status relay

Alarm
Power supply, 0 V 51

44 NC

Power supply, +24 V 52

Power supply, +24 V

43 Status relay, N.C.

Backup, +24 V 53

42 Status relay, shared

Backup, 0 V 54

41 Status relay, N.O.

NC

0V

NC

+24 V

81

NC

82

Status

0V

83

+24 V

NC

84

NC

85

Power supply, 0 V

Technical data
Input
Power supply
Max. input current
Backup power supply
Trigger level for the power supply
Output, power supply
Output voltage
Output power
Output current
Output, status relay in safe zone
Max. voltage
Max. current
Max. AC power
General data
Efficiency degree
Ambient temperature
Storage temperature
Power consumption
Protection degree
Weight
Humidity
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height

21.6...26.4 V DC
4A
21.6...26.4 V DC
Fault < 21 V DC

16.8...31.2 V DC
2.5A

Input voltage -0.5 V DC @ 4 A


max. 96 W
max. 4 A

= U input
= P input
= I input

250 AC / 30 V DC
2 A AC / 2 A DC
500 VA / 60 W

mm
mm2

> 97.9 %
-20...+60 C
-20...+85 C
<2W
IP20
140 g
< 95 %, no condensation
cULus, cFMus, ATEX, IECEx Zone 2, DNV, GOST
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6

100 %
-25...+70 C
-40...+85 C
<2W
IP20
70 g
< 95 %, no condensation
cULus, ATEX, IECEx Zone 2, GL, DNV, cFMus, GOST
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5

Type
ACT20-Feed-In-PRO-S

Type
ACT20-FEED-IN-BASIC-S

Note

Ordering data
Qty.
1

Part No.
8965500000

Qty.
1

Part No.
12824900000

Note

16

Subject to technical changes 03/14 2.15M LIT1126