HOW TO USE HYSYS FOR BUBBLE AND DEW POINT CALCULATIONS
1. Open Aspen HYSYS
2. Start New Case 3. In Simulation Basis Manager add a component list
4. In Component List View, Add Pure Components
5. In Fluid Pkgs add a fluid package
6. Add Peng-Robinson Fluid Package
7. Enter Simulation Environment
8. Add a material stream
9. Double click on material stream
10. Click composition tab to enter composition and enter composition
11. Click conditions tab
Calculation of dew point temperature
To calculate dew point temperature enter pressure, molar flow and vapor fraction. In dew point calculation all system is just on the limit of condensation (thus vapor fraction is 1).
Dew point temperature is calculated automatically. Compare with textbook.
Calculation of bubble point temperature To calculate dew point temperature enter pressure, molar flow and vapor fraction. In dew point calculation all system is just on the limit of vaporization (thus vapor fraction is 0).
Bubble point temperature is calculated automatically. Compare with textbook.
Calculation of dew point pressure
To calculate dew point temperature enter temperature, molar flow and vapor fraction. In dew point pressure calculation all system is just on the limit of condensation (thus vapor fraction is 1).
Dew point pressure is calculated automatically. Compare with textbook.
Calculation of bubble point pressure To calculate dew point temperature enter temperature, molar flow and vapor fraction. In dew point pressure calculation all system is just on the limit of condensation (thus vapor fraction is 0).
Bubble point pressure is calculated automatically. Compare with textbook.