Prepared by: Lokesh Jain, Sr.Engineer(MID), Vikram Cement.

+91 9351962301, +91-7420-230268


SHAFT ALIGNMENT - RIM FACE METHOD
Fill dial gauge reading in highlighted yellow cell around circle. Fill dimension data in Table 1

R0
0
0.000

Radial reading(RIM)
R6
R9
20
20
0.200
0.200

R3
0
0.000

A0
0
0.000

Axial Reading(Face)
A6
A9
10
-5
0.100
-0.050

Table1
A3
15
0.150

Dimensions:
F1
100

F2
200

Dia D
50

MISALIGNMENT
0
R0

VERTICAL OFFESET
VERTICAL AXIAL /100 mm
HORIZONTAL OFFEST
HORIZONTAL AXIAL/100 mm

0
A0

VO
VA
HO
HA

0.100
0.200
0.100
-0.400

CORRECTION
20

R9

RADIAL

R3

R6
20

-5

A9

AXIAL

A3

A6
10

15

VERTICAL PLANE
SHIM F1
SHIM F2
Positive reasult means add shims
Negative reasult means remove shims
HORIZONTAL PLANE
MOVE F1
MOVE F2
Positive means move towards 3.0
Negative means move towards 9.0

0.100
0.300
at mov machine
at mov machine

Dail gauge on movable machine, tip on fix machine


F1, F2 - Distance between rim indicator to macine foot (Front and back)
D - Diameter of circle travelled by face indicator

RIM FACE Method - Dial gauge position

Fix

Mov

Prepared by: Lokesh Jain, Sr.Engineer(MID), Vikram Cement.+91 9351962301, +91-7420-230268

-0.500
-0.900