2.Specifications
Characteristics
HSM-20G
DC 5.00.2V
DC 1.03.0 V
5% RH
2mA
0 to 99% RH
20 to 95% (100% RH intermittent)
< 3%RH
-20 to 70
0 to 50
MAX 2%RH
1.5%
Linearity
1 min
34mm*22mm
3.Reliability Test
No
Item
Method
Impact test
Vibration test
Heat
Resistance
Cool
Resistance
Humidity
Resistance
3
4
5
Temperature
cycle test
Requirment
No breakge,
nor racks
Should be
electrically
normal
Within
5%RH
Within
5%RH
Within
5%RH
Within
5%RH
Within
5%RH
Remark :
- All standard figures are based on humidity variation under
60%RH (at 25 )
- Upon completion of all test, module will be left over under nominal
environment
- And humidity for 24hours.
STANDARD CHARACTERISTICS
%RH
10
20
30
40
50
60
70
80
90
OutpotV 0.74
0.95
1.31
1.68
2.02
2.37
2.69
2.99
3.19
10
20
25
30
40
50
60
Resistance(k)
R-T
10000
100
Center
(k)
10
11
0
12
5
95
80
65
50
35
20
-1
0
-2
5
-4
0
1
-5
5
Rk
1000
10
20
25
30
40
50
60
10
20
25
30
40
50
60
HSM-20G47K
HSM-20S(50K)
R-T
180
160
140
RK
120
100
80
60
40
20
0
0
10
20
30
T
40
50
60