4th stage outlet of sulphur trioxide heat duty

for FAT outlet(m)


Tln
R
S
Tm
assume U=40 w/m2*C
area
Nt
Db
at
Gt
Re
Pr
hi
As
Gs
us
de
Re
Pr
hs
U

74628.023274 kj/hr
20.730023049 kw
69.909807172
42.56291005
0.8835820896
0.9279778393
38.306619045
40
13.529008541
135.70398256
291.27169533
0.0047471406
16667.05065
7967.9216638
1.7331608392
38.932510778
0.0036100871
21916.599823
8766.6399293
11.436357224
8951.6451687
1.7331608392
268.40974553
32.949402154

heat transfer area needed


% excess heat transfer area
shell side pressure drop

16.423980596
21.398257282
9280449110