GEMCO Milner Bay Port Upgrade

Current Action
Data:
Drag coefficient (CD) =
Water density () =
Pile diameter (D) =
Water depth (d) =
Contact Area (An) =
Current speed (v) [m/s]
Drag Force (FD)

1.4
1.025 t/m3
0.433 m
12.8 m
1.888 m2
2
1.5
kN
kN/m
tonne
kN/m
5.419192 0.423374 3.0482953 0.238148

Drag Force (FD) = 0.5 CD v^2 An