You are on page 1of 2

OEM miniature circuit breakers

Line card

Globally rated UL and


IEC circuit breakers UL circuit breakers
FAZ-NA UL 489 breakers QC breakers
Single-, two- and three-pole breakers Single-, two-, three- and
Up to 14 kAIC at 277/480V four-pole breakers
Fulfills both ULT 489 and UL 1077 Up to 65 kAIC at 120/240V

DIN rail mounted HACR rated

B, C and D curves 1-inch breaker

IEC 60947-2

FAZ-NA-DC breakers QCR breakers


Single- and two-pole breakers Single-, two- and
10 kAIC at 125 and 250 Vdc three-pole breakers
125 Vdc per pole Up to 22 kAIC at 120/240V

DIN rail mounted DIN rail mounted

C curve HACR rated


-inch breaker

FAZ UL 1077 breakers QCF breakers


Single-pole, single-pole + neutral, two-, three-, Single-, two- and
four-pole and three-pole + neutral breakers three-pole breakers
Up to 10 kAIC at 277/480V Up to 22 kAIC at 120/240V
Fulfills UL 1077 Front panel mount
DIN rail mounted HACR rated
B, C, D, K, S and Z curves -inch breaker
IEC 60947-2
QCD breakers
FRCmM-NA RCCB Single-, two- and
UL 1053 ground fault three-pole breakers
Two- and four-pole residual 10 kAIC at 240V
current circuit breaker HACR rated
30 and 300 mA ground
DIN rail mounted
fault detection
1-inch breaker
120/208Y and 480/277V options

QC ground fault breakers


FAZ family accessories Single- and two-pole breakers
Shunt trip Up to 22 kAIC at 120/240V
Auxiliary contacts UL 943 ground fault
Busbars 5 mA and 30 mA ground
Lock-off devices fault protection
Undervoltage trip 1-inch breaker

QC family accessories
Mounting plates
DIN rail adapters
Lock-off devices
Specialty lugs

For more information, please visit


www.eaton.com/faz, www.eaton.com/faz-na.

For pricing and availability,


please contact your local sales engineer.
IEC-only circuit breakers
FRCdM digital RCCB FAZT breakers
Four-pole residual current Single-pole, single-pole + neutral,
circuit breaker two-, three-, four-pole and three-pole
System monitoring to prevent + neutral breakers
unwanted trips Up to 25 kAIC at 240/415V
30 mA and 300 mA DIN rail mounted
protection available B, C and D curves
DIN rail mounted Up to 40A

FRBdM digital RCBO AZ breakers


Single-pole + neutral and Single-pole, single-pole + neutral,
two-pole residual current two-, three-, four-pole and three-pole
circuit breaker with overload + neutral breakers
LED status lights Up to 25 kAIC at 240/415V
10 kAIC at 240V DIN rail mounted
DIN rail mounted C and D curves
10, 30 and 100 mA Up to 125A
protection available
Up to 25A Accessories
Shunt trip
xEffect industrial RCCB Auxiliary contacts
Two- and four-pole residual current
Busbars
circuit breaker
Lock-off devices
30, 100, 300 and 500 mA
Motor operators
protection available
DIN rail mounted
Types AC, A, G, G/A, S, S/A, U
and R available

RCBO devices
Single-pole + neutral and three-pole
+ neutral residual current circuit
breaker with overload
10, 30, 100 and 300 mA
protection available
DIN rail mounted
10 kAIC at 240 and 240/415V
Up to 40A

For more information, please visit


www.eaton.com/faz, www.eaton.com/faz-na
and www.eaton.com/mcb.

For pricing and availability,


please contact your local sales engineer.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

2013 Eaton
All Rights Reserved Eaton is a registered trademark.
Printed in USA
Publication No. PA011002EN / Z13862 All other trademarks are property
August 2013 of their respective owners.

You might also like