Details:
Manual: VERITAS NetBackup (tm) 6.0 Troubleshooting Guide for UNIX and Windows

Modification Type: Supplement

Modification:

The following general guidelines can be used to determine if a restart of NetBackup is required
after making changes to the configuration on a NetBackup server or client.

The following terminology is used in this document:

 Daemon: On UNIX, a daemon is a process that keeps running in the background


 Service: On Windows, a service is specifically registered with Windows and interacts with
a service management framework
 ltid: the "Media Manager device daemon"daemon on UNIX. On Windows, this is know as
the NetBackup Device Manager service
 Legacy logging: debug logs traditionally used in NetBackup, enabled by creating a
directory/folder
 Unified logging: debug logs introduced in NetBackup 6.0 under the VxUL (Unified
Logging) framework
 EMM: Enterprise Media Manager; centralized daemon/service that handles resource
management in NetBackup 6.0

The following are some common situations where it may be necessary to restart some or all of the
NetBackup 6.0 daemons:

I. Changing the storage unit configuration


When adding, removing, or modifying a storage unit in NetBackup 6.0, no restarts are necessary.
Changes will take effect for the next backup or restore that uses the storage unit. Any existing
backups will not be updated with the changes if they were started before the changes were made.
Adding: No daemons need to be restarted
Modifying: No daemons need to be restarted
Deleting: No daemons need to be restarted

II. Changing the device (robot/drive) configuration


When adding, removing or modifying a device, some restarts may be necessary depending on the
situation.
Adding: The ltid daemon on all the media servers that access the device need to be restarted.
Modifying: Daemon restart (on one or more than one media server) may or may not be required
depending on the device attributes that are changed.

file://H:\study\netbackup\Upload_site_done\done\New Folder\Some of the situations where is it necessary to... 7/6/2010


DOCUMENTATION: What are some of the situations where is it necessary to restart daemons / services i... Page 2 of 4

- If an attribute like drive cleaning frequency is changed, then no daemons need to be restarted.
- If an attribute like drive type or robot number is changed, then ltid on all the media servers that
access the device need to be restarted.
- If the status column of vmoprcmd displays RESTART for a device path, then the media server
corresponding to the device path needs to be restarted. In addition, if the robot attributes are
changed, then ltid on the server acting as the robot control host may have to be restarted.
Deleting: No daemons need to be restarted.

III. Adding/modifying/deleting a media server


Adding: After NetBackup has been installed, the daemons on that media server need to be started if
not already done so by the installation.
Modifying: No daemons need to be restarted.
Deleting: The media server should be deleted from the EMM server using the nbemmcmd -
deletehost command. No daemons need to be restarted on other media servers. Additional
steps are required to properly decommission a media server. Contact Symantec Enterprise
Technical Services for information on how to properly decommission a media server.

IV. Using the FORCE_RESTORE_MEDIA_SERVER option in the bp.conf file


To override the media server to use for a restore, the FORCE_RESTORE_MEDIA_SERVER
option can be added to the bp.conf file. This does not require any daemons be restarted. This
option will take effect for any future restores. Any restores started prior to making the change will
not be affected.
Adding: No daemons need to be restarted.
Modifying: No daemons need to be restarted.
Deleting: No daemons need to be restarted.

V. Changing policy and schedule configuration


The nbpem daemon in NetBackup 6.0 will handle any updates to policy information. The
nbpem daemon will receive and process updates based on the Policy Update interval set in the
Global Attributes of the master server. The default value is to check for and process updates to
polices every ten minutes.
Adding: No daemons need to be restarted.
Modifying: No daemons need to be restarted.
Deleting: No daemons need to be restarted.

VI. Adding or removing a client


Adding: After NetBackup has been installed, the daemons on the client need to be started if not
done so by the installation.
Deleting: The client being deleted should be removed from any active policies. No daemons need
to be restarted.

VII. Enabling NetBackup logging (legacy or vxlogs) or changing the verbosity


The daemons for which logging is being turned on/off need to be restarted.
Unified logging (VxUL): These logs will be created automatically in /usr/openv/logs. The
vxlogcfg command can be used to change logging levels for unified logging. Changes to the
unified log settings, such as the DebugLevel, will require restarting NetBackup daemons.
Legacy logging:
- Persistent daemons such as bprd, bpjobd, bpdbm, bpcompatd, nbproxy, etc. will
need to be restarted when creating or changing the VERBOSE logging level in the bp.conf file.

file://H:\study\netbackup\Upload_site_done\done\New Folder\Some of the situations where is it necessary to... 7/6/2010


DOCUMENTATION: What are some of the situations where is it necessary to restart daemons / services i... Page 3 of 4

- Other NetBackup processes that are called only when needed such as bpbrm, bptm, bpcd,
bpbkar, etc. will not need to be restarted when creating or changing the logging level. The
changes will take effect the next time the process is started. Note: This will not affect any
processes that were started before the change was made to the logging level.

VIII. Patch installation:


After the NetBackup patch has been installed, the daemons on the host on which the patch was
installed need to be started if not already done so by the installation. For a silent installation, it is
necessary to look at the /us/openv/tmp/install_trace log to determine whether a reboot is needed.

IX. Reboot on upgrade


Reboot only if prompted to do so by the installation
For a silent installation, look at the /us/openv/tmp/install_trace log to determine whether a reboot
is needed

Related Documents:

279295: VERITAS NetBackup (tm) 6.0 Troubleshooting Guide for UNIX and Windows
http://support.veritas.com/docs/279295

Products Applied:
NetBackup Enterprise Server 6.0
NetBackup Server 6.0

Last Updated: December 30 2007 11:44 PM


GMT
Expires on: 12-29-2008
Subscribe to receive critical updates about this
document
Subjects:
NetBackup Enterprise Server
Application: Informational
NetBackup Server
Application: Informational

Languages:
English (US)

Operating Systems:
Solaris
9.0

Symantec World Headquarters:


20330 Stevens Creek Blvd. Cupertino, CA 95014
World Wide Web: http://www.symantec.com/,
Tech Support Web: http://entsupport.symantec.com/,

file://H:\study\netbackup\Upload_site_done\done\New Folder\Some of the situations where is it necessary to... 7/6/2010


DOCUMENTATION: What are some of the situations where is it necessary to restart daemons / services i... Page 4 of 4

E-Mail Support:
http://seer.entsupport.symantec.com/email_forms,
FTP: ftp://ftp.entsupport.symantec.com/ or
ftp://ftp.entsupport.symantec.com/

THE INFORMATION PROVIDED IN THE SYMANTEC SOFTWARE KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY
OF ANY KIND. SYMANTEC SOFTWARE DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL SYMANTEC
SOFTWARE OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES,EVEN IF SYMANTEC SOFTWARE OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT
APPLY.

file://H:\study\netbackup\Upload_site_done\done\New Folder\Some of the situations where is it necessary to... 7/6/2010

You might also like