Reclosers

Electrical Apparatus

Types NOVA15, NOVA27, and NOVA38


Three-Phase, Microprocessor-Controlled 280-42
DESCRIPTION
The Kyle Type NOVA three-phase,
electronically controlled, vacuum-
interrupting automatic circuit
reclosers provide reliable, economi-
cal overcurrent protection, advanced
metering, and automation systems
for distribution circuits rated through
34.5 kV.
The NOVA recloser combines solid
cycloaliphatic-epoxy polymer-
encapsulated vacuum interrupters
with a reliable, lightweight operating
mechanism that utilizes a magnetic
actuator to provide a lifetime of trou-
ble-free operation. The solid polymer
system does not rely on a gaseous,
liquid, or foam dielectric. The Type
NOVA recloser is highly resistant to
ozone, oxygen, moisture, contamina-
tion, and ultraviolet light.
The Type NOVA recloser is available
with two configuration options: control-
powered interface and auxiliary-pow-
ered interface. Designed and tested
to be compatible with Cooper Power
Systems three-phase controls, these Figure 1.
automatic circuit reclosers offer Kyle Type NOVA vacuum-interrupting, three-phase, microprocessor-
superior coordination, protection, controlled automatic circuit recloser.
and application capabilities.
Recloser operations are pro-
grammed in an electronic control Cooper Power Systems is strongly When needed, application expertise,
with accurate characteristics and a committed to improving the reli- backed by world-wide systems engi-
host of advanced features. Precise ability of the electric power industry. neering knowledge and experience,
operating tolerances enable close Technological advances, including is available. Customer-focused
coordination with other protective the newest microprocessor-based design capability, based on more
devices on the system. When system controls and solid insulation NOVA than 65 years of recloser experi-
requirements change, program set- distribution switchgear products, ence, has made Cooper Power Sys-
tings are easily altered with no sacri- represent our investment in the tems the industry leader.
fice of accuracy or consistency. future.
Type NOVA reclosers, like all Kyle
Compact and lightweight, NOVA The Type NOVA recloser is not only reclosers, are designed and manu-
reclosers are easily installed on poles a technological breakthrough, but factured in accordance with ANSI
or in substations. Mounting equip- a valuable component that brings C37.60.
ment is available for both pole and significant operational savings to
ISO 9001:2000 Certified Quality
substation applications. the utility business unit, lowering the
Management System
installation, operation, training, and
Recloser and control accessories maintenance costs on your power
enable further tailoring of the protec- distribution system.
tive program to achieve maximum
system operating flexibility.

December 2009 Supersedes 7/2009 1


Types NOVA15, NOVA27, and NOVA38 Three-Phase, Microprocessor-Controlled Reclosers

RATINGS AND CHARAC- Vacuum Interruption ORDERING


TERISTIC FEATURES A single break on each phase is INFORMATION
Three-phase protection on systems accomplished by separating con- All Type NOVA reclosers include
rated 2.4 through 14.4 kV is provided tacts inside the vacuum interrupter. a Form 6 microprocessor-based
by Type NOVA15 reclosers. Type All arcing is contained within the vac- recloser control. The Form 6 control
NOVA27 reclosers can be applied uum envelope. The patented axial- includes full protection, TCC Editor,
on systems rated through 27.6 kV. magnetic vacuum interrupters, used metering, and diagnostics for your
Higher-voltage system protection at in NOVA reclosers, offers extended application needs.
34.5 kV is provided by Type NOVA38 and increased duty cycles compared
To order a NOVA recloser, electronic
reclosers. A ratings summary for with oil or radial-magnetic interrupt-
control, and control cable:
Type NOVA reclosers is shown in ers. The axial-magnetic field keeps
Tables 13. For ratings and basic the arc in a diffused mode, resulting 1. See the Constructing a Cata-
application information of other Kyle in less arc power to be dissipated, log Number section to construct
reclosers, see Catalog Section 280-05. resulting in low thermal stress, suit- a catalog number that describes
able for encapsulation. the required recloser.
Operation
Surge Protection 2. From Tables 613, specify the
Sensing current transformers, catalog numbers that describe
embedded in the recloser, supply Best operating results are achieved the required recloser accesso-
fault-sensing information to the elec- if reclosers are protected with surge ries.
tronic control. Tripping and closing arresters. On line applications,
signals from the control energize the arrester protection is recommended 3. Order the required electronic
operating circuits in the recloser. Due on both sides of the recloser. (If pro- recloser control (Base catalog
to a single CT ratio for all ratings, tection is on one side only, it should number of the control must be
minimum-trip values of the electronic be on the source side. In substations, included when ordering a Type
control are independent of the arresters should be on the load side.) NOVA recloser).
continuous-current and interrupting Cooper Power Systems distribution- A) From 280-01, Part 70, specify
ratings of the recloser. class arresters provide excellent the required Form 6 recloser
protection and are available with control.
Flexibility in coordination with other mounting brackets to fit Kyle reclos-
protective devices is provided by ers (see Catalog Section 235).
varied timecurrent characteristics from
a choice of standard or customized
curves, minimum trip values, reclosing
and resetting time settings, and a
selection of accessories.

Data plate
Manual OPEN handle

Figure 2.
Kyle Type NOVA recloser.

2
280-42

FEATURES AND DETAILED DESCRIPTION


Kyle NOVA microprocessor- Construction Hydrophobicity
controlled, three-phase reclosers The module maintains excellent
protect systems operating through Recloser
hydrophobicity, a property character-
34.5 kV (see Ratings and Speci- Designed for long service life and no ized by water beading into isolated
fications section of this catalog). maintenance, the NOVA recloser has drops, and is highly resistant to
These ratings and the wide range of three solid-polymer interrupter mod- moisture absorption. Hydrophobicity
programmable settings provided by ules with embedded current trans- prevents continuous sheets of water
Cooper Power Systems electronic formers and a standard aluminum from forming leakage current paths
controls permit meeting a variety of mechanism housing; light gray is the that deteriorate the creepage with-
application requirements. standard color. stand level.
Recloser Operation Cycloaliphatic-epoxy polymer encap- Ultraviolet Resistance
Fault currents are sensed by three sulation provides solid insulation and
maintenance-free, environmentally The cycloaliphatic epoxy resists
1000:1 ratio sensing current trans- ultraviolet radiation damage even in
formers embedded in the recloser. safe operation. There is no monitor-
ing or maintaining of gas pressure harsh climates, maintaining a smooth,
These CTs provide a continu- unblemished, self-cleansing surface
ous measurement of line current, or oil levels; there are no toxic or
environmentally unfriendly materials. with low-adhesion to contaminants.
monitored by the electronic control.
When current level exceeds the There are no foam fillers or insulation Tensile Strength
programmed minimum trip level, seals, eliminating potential moisture
ingress areas. The NOVA recloser Outstanding tensile and flexural
the magnitude of the overcurrent strength characteristics mean the
is integrated with time, using a pro- module exhibits good absorption
of elastic energy and resistance to NOVA recloser modules are tough
grammed timecurrent curve char- and non-fragmenting, reducing ship-
acteristic. The control then signals cracking and crack propagation.
Additionally, durable environmental ment and handling charges.
the trip in the recloser, opening the
main contacts of all three phases. properties make the solid polymer Shed Design
suitable for outdoor applications,
The control signals tripping and clos- including seacoasts, deserts, and The shed design utilizes alternate-
ing. The recloser always maintains areas of high pollution. sized skirts. The major sheds shield
energy for a tripping operation fol- and protect the minor sheds to
lowing a closing operation. Surface Tracking enhance the hydrophobicity and
The cycloaliphatic epoxy is highly ultraviolet resistance of the module,
The electronic recloser control provides eliminate formation of microcracks,
determination of phase- and ground- resistant to contaminants and
resists tracking and flashovers under and ensure extra-protected creep-
trip sequences and operations to age. Additionally, sharp edges direct
lockout and reclosing and resetting extreme pollution levels to reduce
both flashovers and the associated water away from the unit. Water
timing, adjustable with the control paths and ice formations are effec-
without de-energizing the recloser. cost of repairs.
tively eliminated.
Heater Magnetic Actuator OPEN/CLOSE Manual OPEN Handle Mechanical Operations Counter Heater
Contact Position
Indicator

Aluminum Mechanism Trip-and-Close Actuator Board Auxiliary Input Control Cable Ground Connector
Housing (Standard) Capacitors Power Receptacle Receptacle #10 - #2 Stranded
Figure 3. 020051KM

Kyle Type NOVA recloser Type B mechanism with auxiliary-powered interface (view from bottom of recloser
with bottom cover and actuator board safety shield removed).

3
Types NOVA15, NOVA27, and NOVA38 Three-Phase, Microprocessor-Controlled Reclosers

Flashover Recovery Enclosed in the interrupter are a Control-Powered


Flashovers occur when an object, stationary and a moving contact Interface
usually wildlife, contacts energized assembly. The moving contact has a
travel of approximately one-half inch, The Type D NOVA recloser mecha-
parts of the equipment. The NOVA nism (see Figure 5) with the control-
recloser minimizes the effect of flash- its shaft passing through a flexible
bellows that maintains vacuum integ- powered interface is fully operational
overs with remarkable physical resil- with Kyle Form 5 and Form 6
ience, arc-quenching properties, and rity. Contacts consist of a high purity
copper sintered with aluminathermic VTC-ready, microprocessor-based
a self-healing ability. NOVA recloser controls equipped with the required
can withstand the enormous forces chromium.
DC-to-DC converter, interface cir-
experienced during faults without Because the smallest amount of cuit, and a fully shielded 19-pin
wholesale damage and allows re- internal contamination can signifi- cable. It is not compatible with the
energizing after external flashover cantly shorten the life of a vacuum Types F3A nor FXB controls. The
without cleaning. interrupter, special care is taken to control-powered interface includes
avoid even minute contamination a 19-pin receptacle on the recloser
Vacuum Interrupters from any source, including dust par- and an internal heater (for humidity
Type NOVA reclosers use vacuum ticles, machining oils, or human body control) powered from the control
as the interrupting medium. Vacuum salts. No paraffinic oils are used in input power supply (AC or DC). The
interrupters (Figure 4) provide fast, the machining process, all machined DC-to-DC converter board converts
low-energy arc interruption with parts are put through a cleaning/ the controls 24 VDC battery supply
long contact and interrupter life, low degreasing process, and then all to 53 VDC to charge the trip/close
mechanical stress, and maximum components are electro-polished capacitors in the NOVA recloser
operating safety. With arc interrup- in a positive-pressure, air-filtered mechanism. The DC-to-DC con-
tion taking place in a vacuum, con- area. A Class 100 clean room facil- verter board also houses voltage
tact and interrupter life are several ity is used for the final interrupter monitoring and conditioning circuits
times greater than with interruption production. The furnaces employ that protect the battery from failure
in oil, virtually eliminating interrupter a custom-designed, three-stage and provide trip/close operations
maintenance. pumping system to yield high levels without ac power. In the absence of
of vacuum. Every vacuum interrupter AC power to the electronic control,
is then tested and tracked with indi- the control battery will provide the
vidual serial numbers. trip and close operations. A com-
Electronic Control plete four-trip sequence with minimal
reclose intervals as configurated for
Types NOVA15, NOVA27, and each control is obtainable without
NOVA38 reclosers are controlled AC power. The recloser and control
by a Cooper Power Systems three- system is capable of exceeding over
phase electronic recloser control. one thousand operations on battery
A choice of microprocessor-based power only.
controls are available to use in con-
junction with these reclosers.

Figure 4.
Cross section of a vacuum inter-
rupter used in NOVA reclosers. Potential
Transformer
(120/240 Vac)
Kyle vacuum interrupters are designed
O
P
E
N

with a metal and ceramic housing for


C
L
O
S
E
D

maximum strength and long-term


vacuum integrity. Oxygen-free, high-
conductivity copper, stainless steel,
and a nickel-copper alloy are used
in the vacuum interrupters. The high- Electronic
alumina ceramic has more than five Control
times the strength of glass, which
permits a higher processing tempera- 120/240 Vac
ture to develop maximum purity of Power Cable
19-Pin
the assembly, and is impervious to (optional)
Control Cable
helium penetration, maintaining the
vacuum level. Additionally, it provides Figure 5.
wear resistance, chemical resistance, Control-powered NOVA recloser configuration with potential trans-
and a high dielectric strength. former input power.

4
280-42
Similarly, the recloser can be operated
from the manual control switch on the
electronic control panel, provided the
Potential manual operating handle is up. A red
Transformer contact position indicator flag, adja-
E
P
O
(120/240 Vac) cent to the manual operating handle,
shows recloser contact position.
N

Internal Voltage Sensor


Option
Electronic
Control The NOVA recloser is available with
internal voltage sensors at time of
120/240 Vac order. Using a high-voltage resistor
Power Cable
14-Pin
(optional)
within each interrupter module with
Control Cable source-side connections, the sensing
option, cable, and control support
2-Pin Auxiliary-Powered Output Cable* a magnitude accuracy of 2% or bet-
ter and a phase degree accuracy of
*Note: Control receptacle ordered separately. 1.5. The internal voltage sensing
Figure 6. option is compatible with a Form 5 or
Auxiliary-powered NOVA recloser mechanism configuration with Form 6 Pole-Mount controls.
potential transformer input power.
Accessories
Auxiliary-Powered AC Auxiliary Input Auxiliary Switch
Interface The trip-and-close capacitors are
A three-stage auxiliary switch can be
The Type B NOVA recloser mechanism charged through both the AC aux-
provided as an accessory. Each stage
(see Figure 6) with the auxiliary-pow- iliary input power and the recloser
has two independent contacts that permit
ered interface is fully operational with control. Upon loss of AC power,
any desired combination of a (follow
standard Form 6 microprocessor- the capacitors will be continuously
state of recloser contacts) and b
based controls and standard 14-pin charged from the control battery to
(opposite recloser contacts) positions.
control cables. The auxiliary-powered allow tripping and will also be trickle-
The switch contacts are insulated for
interface includes a 14-pin recep- charged to allow for back-up clos-
600 V and have a continuous current
tacle on the recloser and an internal ing. The charge on the capacitors
rating of 10 A. Their interrupting rat-
heater (for humidity control) powered will be maintained for the duration of
ings are shown in Table 5.
from the auxiliary input power supply. the control battery power. Allow one
The Type B NOVA recloser mecha-
minute between back-up close oper- Terminals
ations to recharge the capacitors.
nism, with the auxiliary-powered The standard terminal is an eyebolt,
However, the NOVA recloser is ready
interface, requires a voltage source 1/0500 mcm (630 A). Eyebolt 4/0
to trip immediately after performing a
of 48 VDC, 125 VDC, 250 VDC, 120 1000 mcm (800 A), 2-hole and
back-up closing. Should the battery
VAC, or 240 VAC, which must be 4-hole, flat-pad terminals, and stud-
power discharge to the disconnect
specified at the time of order. The type terminals are available as an
level, back-up closing is disabled
auxiliary-powered interface is con- accessory.
until AC auxiliary power is resumed.
nected to a 2-pin male receptacle Apply AC auxiliary input power to Pole-Mounting Hanger
located next to the 14-pin female the NOVA recloser to recharge the
control receptacle. The voltage A pole-mounting hanger, which bolts
capacitors.
source is used to maintain power to directly to the recloser frame, is avail-
the trip-and-close capacitors in the Manual Operation able for pole-mounting installation.
recloser and to power the heaters.
The recloser can be opened manu- Arrestor-Mounting Brackets
DC Auxiliary Input ally with a hotstick to pull down the
yellow manual OPEN handle under The arrestor-mounting bracket acces-
The trip-and-close capacitors are sory can be bolted to the recloser
the sleet hood. With the handle in
maintained from the DC source. frame and pole-mounting hanger for
the OPEN position, the control can-
Upon loss of the DC power, the trip- the addition of inboard and outboard
not close the recloser.
and-close capacitors will maintain trip arresters. The arresters are not
and close power for several minutes. The recloser is closed, following a included with the brackets.
If the trip-and-close capacitors are manual open, by pushing the yellow
discharged, the recloser is inoperative handle back under the sleet hood Substation-Mounting Frame
until DC power is resumed. and then using the microprocessor
control to close the recloser. A substation-mounting frame acces-
sory is available for substation-
mounting applications.

5
Types NOVA15, NOVA27, and NOVA38 Three-Phase, Microprocessor-Controlled Reclosers

RATINGS AND SPECIFICATIONS

TABLE 1
Voltage Ratings (kV)
Description 15 kV 15 kV 27 kV 27 kV 38 kV

Maximum Voltage 15.5 kV 15.5 kV 29.2 kV 29.2 kV 38.0 kV


Rated Basic Impulse Level 110.0 kV 125.0 kV 125.0 kV 150.0 kV 170.0 kV
Radio Noise Limit (V) 100 @ 9.4 kV 100 @ 9.4 kV 100 @ 16.4 kV 100 @ 16.4 kV 100 @ 23.0 kV
Power Frequency Withstand, Dry 50 kV 50 kV 60 kV 60 kV 70 kV
Power Frequency Withstand, Wet 45 kV 45 kV 50 kV 50 kV 60 kV

TABLE 2
Current Ratings (Amperes)
Description 15 kV 15 kV 27 kV 27 kV 38 kV

Rated Continuous Current 630 A* 630 A* 630 A* 630 A* 630 A*


Short Circuit Current, Symmetrical 12.5 kA** 12.5 kA** 12.5 kA** 12.5 kA** 12.5 kA
Making Current, Asymmetrical Peak 31.0 kA 31.0 kA 31.0 kA 31.0 kA 31.0 kA
Cable Charging Current 10 A 10 A 25 A 25 A 40A

*800 amp accessory is also available.


**16.0 kA option is also available. (Making Current is 40.0 kA Asymmetrical Peak.)

TABLE 3
Mechanical Ratings
Description 15 kV 15 kV 27 kV 27 kV 38 kV

Min. Mechanical/Electrical Operations


Without Maintenance (C-O) 10,000 10,000 10,000 10,000 10,000
Mass (Weight) - kg (lbs) 86 (190) 91 (200) 91 (200) 101 (223) 101 (223)

TABLE 4
Duty Cycle
Percentage of Number of Minimum
Type Interrupting Rating Unit Operations Circuit X/R Value
NOVA 15-20 88 4
45-55 112 8
90-100 32 15
Total 232

TABLE 5
Auxiliary Switch Interrupting Ratings
Non- Non-
Inductive Inductive Inductive Inductive
AC AC DC DC
Volts (amps) (amps) (amps) (amps)

24 15.0 20.0
48 7.5 10.0
120 60 80
125 1.5 2.0
240 30 60
250 0.45 0.5

6
280-42

DIMENSIONS

271
Terminal (10.75) A
Connectors
1/0 - 500 MCM 388 388
(Standard)
(15.5) (15.5)
A
A

Terminal
Connectors B
1/0 - 500 MCM
(Standard) C

O
P
N
E 285
(11.25)
C
L
O
S
E
D

285 1000
(11.25) (39.50)
413
(16.25)
Note:
NOTE:AllAlldimensions areare
dimensions mmmm (inches).
(inches).
Dimensions
Dimensions shown
shown are approximate.
are approximate.

Terminal Options A B C

yebolt, 1/0 - 500 mcm


E 80 (3.25) NOVA15 791 508
Cable Range (630 A maximum) 110 kV BIL (31.25) (20)

Eyebolt, 4/0 - 1000 mcm 108 (4.25) NOVA15 847 564


Cable Range (800 A maximum) 125 kV BIL (33.25) (22.25)

lat Pad, 2-hole


F 114 (4.5) NOVA27 847 564
(630 A maximum) 125 kV BIL (33.25) (22.25)

lat Pad, 4-hole


F 121 (4.75) NOVA27 946 663
(800 A maximum) 150 kV BIL (37.25) (26.0)

Stud Type, 1.125 - 12 threads 82 (3.25) NOVA38 946 663


(800 A maximum) 170 kV BIL (37.25) (26.0)

Creepage Distances

Description 15 kV 15 kV 27 kV 27 kV 38 kV
110 kV BIL 125 kV BIL 125 kV BIL 150 kV BIL 170 kV BIL

Terminal to terminal 1052 1052 1052 1052 1052


(41.5) (41.5) (41.5) (41.5) (41.5)

Lower terminal to ground/earth 673 772 772 950 950


(26.5) (30.5) (30.5) (37.5) (37.5)

Figure 7.
Type NOVA recloser dimensions, NOVA27 shown.

7
Types NOVA15, NOVA27, and NOVA38 Three-Phase, Microprocessor-Controlled Reclosers

Note: All dimensions are mm (inches).


Dimensions shown are approximate.

Pole

1089
(43.0)
637
(25.0)
592 Min.
(23.25) A

Mounting
Holes 290 N
E
P
O

for (11.5)
0.75 Bolts
686 mm
(27 in)

779
(30.75)
Pole
Pole

Terminal Options A

yebolt, 1/0 - 500 mcm
E 80 (3.25) Dimension B
Cable Range (630 A maximum)
NOVA15 791
Eyebolt, 4/0 - 1000 mcm 108 (4.25) 110 kV BIL (31.25)
Cable Range (800 A maximum)
NOVA15 847
lat Pad, 2-hole
F 114 (4.5) 125 kV BIL (33.25)
(630 A maximum) NOVA27 847
125 kV BIL (33.25)
lat Pad, 4-hole
F 121 (4.75)
(800 A maximum) NOVA27 946
150 kV BIL (37.25)
Stud Type, 1.125 - 12 threads 82 (3.25) NOVA38 946
(800 A maximum) 170 kV BIL (37.25)

Figure 8.
Dimensions of Type NOVA recloser with pole-mounting hanger and arrester-mounting bracket accessories.

8
280-42
Note: All dimensions are mm (inches).
NOTE: All dimensions
Dimensions areapproximate.
shown are mm (inches).
Dimensions shown are approximate.

C
O
P
E
N

870
(34.25)

2216
(87.25)
adjustable to
2826
(111.25)
in
76 (3)
increments

965
(38) 457
(18)
1060 19 (0.75) 552
(41.75) Mounting Hole (4) (21.75)

Terminal Options A B C
yebolt, 1/0 - 500 mcm
E 80 (3.25) NOVA15 791 508
Cable Range (630 A maximum) 110 kV BIL (31.25) (20)
Eyebolt, 4/0 - 1000 mcm 108 (4.25) NOVA15 847 564
Cable Range (800 A maximum) 125 kV BIL (33.25) (22.25)
lat Pad, 2-hole
F 114 (4.5) NOVA27 847 564
(630 A maximum) 125 kV BIL (33.25) (22.25)
lat Pad, 4-hole
F 121 (4.75) NOVA27 946 663
(800 A maximum) 150 kV BIL (37.25) (26.0)
Stud Type, 1.125 - 12 threads 82 (3.25) NOVA38 946 663
(800 A maximum) 170 kV BIL (37.25) (26.0)

Figure 9.
Dimensions of Type NOVA recloser with substation-mounting frame accessory.

9
Types NOVA15, NOVA27, and NOVA38 Three-Phase, Microprocessor-Controlled Reclosers

CONSTRUCTING A CATALOG NUMBER


To order a basic Type NOVA recloser with eyebolt terminals, for use with 120 VAC closing and a 14-pin control cable, the
catalog number would be constructed like this:

KNOVA Basic letters for a Type NOVA recloser with base Form 6 recloser control*
15A Recloser Type:
15A for 15 kV, 630 A continuous, 12.5 kA interrupting
27A for 27 kV, 630 A continuous, 12.5 kA interrupting
38A for 38 kV, 630 A continuous, 12.5 kA interrupting
1 Bushing Terminals:
1 for eyebolt terminal, 1/0 to 500 MCM, 630 A max.
3 for 2-hole flat pad terminal, 630 A max.
4 for 4-hole flat pad terminal, 800 A max.
5 for stud-type terminal, 800 A max.
1 Interface:
1 for Type NOVA AP, with auxiliary-powered interface 120 VAC closing (14-pin & 2-pin receptacles)
2 for Type NOVA AP, with auxiliary-powered interface 240 VAC closing (14-pin & 2-pin receptacles)
3 for Type NOVA CP, with control-powered interface (19-pin receptacle), 120 VAC Heater
4 for Type NOVA CP, with control-powered interface (19-pin receptacle), 240 VAC Heater
5 for Type NOVA AP, with auxiliary-powered interface 125 VDC closing (14-pin & 2-pin receptacles)
6 for Type NOVA AP, with auxiliary-powered interface 250 VDC closing (14-pin & 2-pin receptacles)
7 for Type NOVA AP, with auxiliary-powered interface 48 VDC closing (14-pin & 2-pin receptacles)

KNOVA 15A 1 1
KNOVA15A11 is the catalog number for the required basic Type NOVA recloser.

* Include the base catalog number of the selected control when ordering a Type NOVA recloser.
Standard terminal, included when ordering a Type NOVA recloser.

TABLE 6 TABLE 8
BIL Options Continuous Current Options*

Catalog Catalog
Description Number Description Number
15 kV 125 kV BIL . . . . . . . . . . . . . . . KNOVA28-1 15 kV 800 A option . . . . . . . . . . . . . . KNOVA22-1
27 kV 150 kV BIL . . . . . . . . . . . . . . . KNOVA25-1 27 kV 800 A option . . . . . . . . . . . . . . KNOVA24-1
38 kV 800 A option . . . . . . . . . . . . . . KNOVA27-1

* When ordering the standard eyebolt terminal in conjunction


with the 800 A option, eyebolt terminals suitable for 4/0
TABLE 7
1000 mcm conductors will be provided.
Interrupting Rating*

Catalog TABLE 9
Description Number Internal Voltage Sensing Option*
16 kA Maximum Interrupting . . . . . . . 16 kA
*Applicable to KNOVA15A/27A only Catalog
Description Number
Internal Voltage Sensing option,
15 and 27 kV . . . . . . . . . . . . . . . . . KNOVA-848
Internal Voltage Sensing Cable
(basic cable, no length) . . . . . . . . . KA97ME
Internal Voltage Sensing Cable,
maximum 50 feet
Replace X with number of feet. . . . KA97ME-X

* Available with Form 5 and Form 6 Controls only.

10
280-42
TABLE 10
Mounting Equipment
Catalog
Description Number
Single pole-mounting hanger with stainless steel hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA54-3
Single concrete-pole-mounting hanger with stainless steel hardware . . . . . . . . . . . . . . . . . . . . . . . . KNOVA54-4
Surge-arrester-mounting brackets with stainless steel hardware
Inboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA61-2
Outboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA61-1
Alley-pole-mounting hanger with stainless steel hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA352-1
Arrester brackets (set of 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA353-1
Arrester brackets (set of 6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA353-2
Substation-mounting frame with stainless steel hardware
includes control-mounting bracket for FXA, FXB (single- and double-size cabinet),
Form 5, and Form 6 Yard and Pole Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA59-1
Field kit for NOVA recloser on substation-mounting frame KA89WV1 . . . . . . . . . . . . . . . . . . . . . . . . KNOVA457-1
Field kit for NOVA recloser on substation-mounting frame KA584R1 . . . . . . . . . . . . . . . . . . . . . . . . KNOVA457-4

TABLE 11
Factory Assembly
Catalog
Description Number
Recloser in single pole-mounting hanger KNOVA54-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA354-1
Recloser in single pole-mounting hanger KNOVA54-3 with arrester brackets . . . . . . . . . . . . . . . . . . KNOVA354-2
Recloser on alley-pole-mounting hanger KNOVA352-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA456-1
Recloser on alley-pole-mounting hanger KNOVA352-1 with arrester brackets . . . . . . . . . . . . . . . . . KNOVA456-2

* Covers factory assembly only; recloser, control, and mounting equipment must be ordered separately.
TABLE 12
Auxiliary Switch
Catalog
Description Number
Three-stage auxiliary switch with six independent contacts
and receptacle for KNOVA82 cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA66-2
Auxiliary switch cable for KNOVA66-2, auxiliary switch to control,
(basic cable, no length) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA82
Auxiliary switch cable, maximum 100 feet.
Replace X with number of feet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA82-X

TABLE 13
Miscellaneous Accessories

Catalog
Description Number
Low-voltage AC input cable (auxiliary-powered Type B interface only, basic cable, no length) . . . . . KA11ME1
Replace X with number of feet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA11ME1-X
Source and load wildlife guards, 630 A recloser (set of 6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOVA56-6
Source and load wildlife guards, 800 A recloser (set of 6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KGS560-6

11
Types NOVA15, NOVA27, and NOVA38 Three-Phase, Microprocessor-Controlled Reclosers

2009 Cooper Industries. All Rights Reserved.


Cooper Power Systems, Kyle, and NOVA are valuable trademarks of Cooper
Industries in the U.S. and other countries. You are not permitted to use Cooper 2300 Badger Drive
trademarks without the prior written consent of Cooper Industries. Waukesha, WI 53188 USA
ANSI is a registered trademark of the American National Standards Institute. www.cooperpower.com

You might also like