You are on page 1of 2

datasheet for activated Carbon filter vessel

PROCESS DATA

MINIMUM FLOW (PER 18.6 m3 / hr


STREAM)
NORMAL FLOW (PER 51.1 m3 / hr
STREAM)
DESIGN FLOW (PER 62.0 m3 / hr
STREAM)
TYPE of flow VERTICAL, DOWN-FLOW
HYDRAULIC 9/ 17.5 m3 /m2/hr
LOADING(MIN/MAX)
INFLUENT TSS < 2/3 ppm
CHARACTERISTICS NORMAL/DESIG
N
COD 113.6/128
NORMAL/DESIG
N
TDS (DES) 2187 ppm
CHLORIDES 789 ppm
EFFLUENT TSS < 2 ppm
CHARACTERISTICS COD 85 / 100
(NORMAL/DESIG
N)

DESIGN DATA

DESIGN PRESS. (barg) 8

OPER. PRESS. (barg) 4.5

DESIGN TEMP (C) 82

OPER. TEMP (C) 43


SHOP
(1.3 X MAP)
HYDROTEST( barg)

Material of construction of filter vessel

SHELL SA 516-Gr. 70

HEADS SA 516-Gr. 70, 2:1 SEMI ELLIPSOIDAL

INT. (WELDED) SA 516-Gr. 70

SUPPORTS SA 36

FLANGES SA 105

STRAINER PLATE SA 516-Gr. 70 LINED

NOZZLE PIPE / SA 106-Gr. B


NECK
GASKETS 3 mm THK REINFORCED FLEXIBLE
GRAPHITE

BOLTS, EXTERNAL SA-193-Gr. B7 GALV.

BOLTS, INTERNAL SA-193-Gr. B8M

NUTS, INTERNAL SA- 194 Gr.8M HEX. NUT

CLIPS SA 516-Gr. 70