10
64 AI LOCAL EHC P*LBA10CT013 MAIN STEAM TEMP(A)(SECOND PIPE) 0 600 degC 4-20 mA OK 3/26/2017(Need Scaffolding)
Wrong Temp Indicating HMI.
Need To Reconfirm the loop
160 ANALOG LOCAL DCS P*MAA10CT011B TURBINE 1ST STAGE INNER METAL TEMP 0 600 degC 4-20 mA Not Ok Sunday, March 26, 2017
From Juction box to sensor cable
Missing
AVR/
449 DO EHC P*MAY50EW001 TURBINE TRIPPED(TO AVR) - - - 220VDC
GCP
System Name