You are on page 1of 4

DENSADEG

1)041)03064 */%6453*"-
$-"3*'*$A5*0/ 40'5&/*/( ! Applications
3&.0VAL "11-*$A5*0/4
- Wastewater:
Applications
t$40440
t#0% $0% 5443FEVDUJPO
t1SJNBSZBOE5FSUJBSZ$MBSJDBUJPO
t1IPTQIPSPVT3FNPWBM
tWBTUFXBUFS3FDMBNBUJPO
%SJOLJOHWater:
t$MBSJDBUJPOBOE4PGUFOJOH
t.FNCSBOF'JMUFS#BDLXBTI
t5IJDLFOJOH
t0SHBOJDT3FNPWBM
*OEVTUSJBMWater:
t1SPDFTTWater
t4PGUFOJOH4JMJDB3FNPWBM
t.FUBM1SFDJQJUBUJPO
t'(%Wastewater

The DensaDeg Clarifier/Thickener is a high-rate


solids contact clarifier which combines optimized
flocculation, internal and external sludge recirc-
ulation, and plate settling in two conjoined vessels.
MAIN FEATURES
)JHIMPBEJOHSBUFFRVBMTTNBMMGPPUQSJOU 5IJDLFOFSQSPWJEFTTMVEHFTUPSBHFBOETMVEHF
$PNQBDUMBZPVU*OUFHSBUJPOPGDMBSJDBUJPO UIJDLFOJOH
BOEUIJDLFOJOHJOBTJOHMFTZTUFN &BTJMZIBOEMFTJOVFOUTPMJETWBSJBUJPOT
)JHIMZFDJFOUVTFPGDIFNJDBMT /PNBJOUFOBODFDPODFSOTSFMBUFEUPBCSBTJWF
&YUFSOBMTMVEHFSFDJSDVMBUJPOBOEIJHITPMJET XFBSCZFYUFSOBMCBMMBTU
DPODFOUSBUJPOSFEVDFTTUBSUVQUJNF
4VQFSJPSFVFOURVBMJUZ


SEPARATION TECHNOLOGY: DensaDeg 2D CLARIFIER/THICKENER
The DensaDeg Clarifier, Softener and Thickener is the water and recirculation reduces waste volumes and results in rapid settling
wastewater industrys most robust, versatile process on the market. operation and high quality treated water. The DensaDeg process
This high-rate system combines optimized flocculation, internal is proven in hundreds of installations on nearly all physical-
and external solids recirculation, thickening in two conjoined chemical separation applications in the municipal drinking water,
vessels to maximize hydraulic loading and treatment efficiencies. wastewater and industrial markets.
The proprietary blend of energy input and high volume solids
DENSADEG
HOW IT WORKS
An Integrated Three-Stage Process
1 RAPID MIX STAGE: Raw water flows into the rapid (flash) 4 SETTLING & SEPARATION ZONE: Flocculated solids enter the
mix zone where a coagulant is added. Coagulation is the settling zone, over a submerged weir wall, where dense,
destabilization of colloidal particles, which facilitates their suspended matter settles to the bottom of the clarifier. Clarified
aggregation and is achieved by the injection of a coagulant water is displaced upward from the downward moving slurry,
such as alum or ferric chloride. through inclined tube settlers. The tube modules act as a
polishing step for lighter, low density solids.
2 REACTOR ZONE: Coagulated water then flows into a second
reactor zone for intense internal recirculation and mixing by an 5 SLUDGE DENSIFICATION & THICKENING: Settled sludge is
axial-flow turbine. Water and solids are recirculated in and out thickened progressively in the bottom of the clarifier through
of a cylindrical draft tube, promoting solids contact and particle the use of a rotating scraper mechanism. A small portion of
growth. A flocculating agent (polymer) is injected inside the this thickened sludge is recycled to the reactor zone and the
reactor draft, together with thickened sludge recycled from remainder is periodically blown down through an automatic
the thickening zone. The recycled sludge accelerates the blowdown valve.
flocculation process and ensures the formation of dense floc 6 EFFLUENT COLLECTION: Uniform collection of clarified water
particles of homogeneous size.
is accomplished in effluent launders above the settling tube
3 TRANSITION ZONE: The transition to the settling stage is assembly.
accomplished through an up-flow piston zone. Additional
flocculation takes place in this zone, as dense particulate
transitions upward and over an internal weir wall.

DensaDeg

Reactor Draft Tube


Reactor Drive
Collection
Troughs
Tube
Settlers
Rapid Mixer 6

3
4

1 scraper mechanism
2

Sludge
Sludge Recycle Blowdown
RAW WATER SOURCE DENSADEG DUAL MEDIA FILTERS UV or CL2 DISINFECTION

DRINK/PROCESS WATER

SECONDARY SECONDARY
DENSADEG DUAL MEDIA FILTERS UV or CL2 DISINFECTION
FILTRATION CLARIFICATION
TERTIARY TREATMENT (PO4 REMOVAL AND CLARIFICATION)

PERFOMANCE ADVANTAGES
Excellent Effluent Quality Technical Features
Combined solids recirculation and high reactor concentration
optimize unit operation and overall treatment results. Loading Rates: 6.0 to 15.0 gpm/ft2
Treated water turbidity is normally less than 1.0 NTU. Steel tank or concrete units available
Tertiary phosphorous removal to less than 0.1 mg/l TP.
Construction Economy Highly efficient use of chemicals
Integrated functions within a single unit require approximately Flexible layout options - Customize
50% less space than conventional solids contact clarifiers.
to any size plan
Accelerated and Optimal Chemical Efficiency
Combined internal and external sludge recirculation and high Unit heights of 15 to 22 feet
reactor solids concentration reduce startup time and chemical
usage and increase treatment rates.
10 times less waste volume
vs. ballasted systems
Thickened Sludge and Reduced Waste Volume
Thickened solids from 2 to 10% and extremely low waste volume. No additional thickening
Consistent, Flexible Performance equipment required
Hydraulic loading management and high reactor solids
Automatic control of start-up, shutdown
enables operation over a broad range of flows and raw water
characteristics. and sludge systems
Long Service Life No abrasive ballast material to handle,
No abrasive material is added to the system so there is no wear dispose of or replace
on pumps, mixers, or scrapers.
Enhanced TOC removal with softening

DESIGN SPECIFICATIONS

DensaDeg
Single Unit Capacity DESIGN SPECIFICATIONS
MGD
Concrete or Steel Tank construction
Concrete Units 1.0 to 22
Mechanism Internals: Painted carbon steel, stainless steel or
Steel Tank Units 0.15 to 15 special coatings
http://www.degremont.com

Copyright 2009 - Degrmont

You might also like