TAGTPL2-PT JANUARY 2008

Terrain Soil and Waste


Product Guide

TERRAIN
DRAINAGE
Introduction
Having pioneered the development of solvent-welded systems, Terrain soil and
waste products represent the industry benchmark for quality, installation
flexibility and product innovation backed by the highest levels of customer
service.
Terrain systems include an extensive range of soil and waste drainage products
for commercial, industrial, housing and public sector developments, all built on
the strength of our Terrain brand.
Systems include solvent-welded and push-fit options for both soil and waste
drainage; overflow and trap systems; and a comprehensive range of adaptors
and accessories. Products are available in a range of colours.
Industry leading range of solvent and push-fit soil and waste solutions.
Unique products offer unrivalled installation options.
High quality finish colour matched to Terrain rainwater systems.
Suitable for commercial and domestic installations.

Terrain Soil System


100-Solvent
82, 110 and 160mm PVC-u soil pipes and fittings
Wide range of bends, branches and access fittings to meet all application
requirements
BBA certified Air Admittance Valve

Terrain Soil System


100P-PushFit
82, 110 and 160mm PVC-u soil pipes and fittings for push-fit jointing
Saves time and labour costs
Also for use with Terrain roof outlets for rainwater drainage

Terrain Waste System


200-Solvent
Solvent-welded MuPVC system
32, 40 and 50mm integrated systems
Wide range of bends and adaptors
Integrated floor gullies

Terrain Waste System


300-PushFit
Push-fit polypropylene system
32, 40 and 50mm integrated systems
Quick and easy to install
Saves time and labour costs
Resistant to most oils, bleaches and detergents
Wide range of bends and fittings

Terrain Overflow System


500-Overflow
Solvent-welded PVC-u system for cold, non-pressure water
19mm PVC-u pipe and fittings
Range of tank connectors

Terrain Traps
600-Traps
Polypropylene traps
32, 40 and 50mm polypropylene traps
Range includes telescopic and self resealing bottle traps
All traps have universal compression outlets which, in addition to all
Terrain waste pipes, will accept: other MuPVC waste pipe
Contents

RANGE INTRODUCTION

TERRAIN SOIL SYSTEMS


100 Solvent-Weld 2-13
100P Push-Fit 14-18

TERRAIN WASTE SYSTEMS 19-26


200 Solvent-Weld 19-24
300 Push-Fit 25-26

TERRAIN OVERFLOW SYSTEM 27-28


500 system 27-28

TERRAIN TRAPS 29-30


600 system 29-30

ACCESSORIES/ANCILLARIES 31-32

SYSTEM PLANNING 33-36


Design considerations 33
Special fabrication service 34-35
Design data 36-37
Socket dimensions 38

NUMERICAL INDEX 39-40


Technical advisory service &
quality details 41

Products marked : in the


product listings are available
in CAD form for ready
incorporation into design
drawings. If youd like a disk
or CD ROM in the appropriate
format, simply contact the
Technical Advisory Service.
1
100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
SOIL PIPE Plain ended. AVAILABLE AS SINGLE ITEMS
size(mm) L T Code Col Pk/St

:
(min)

:
* 82 3m 3.2 10.87 100.3.30 GBW 2/88 8

:
L * 82 4m 3.2 10.87 100.3.40 GBW 2/88 46.38
* 110 3m 3.2 11.07 100.4.30 GBWR 2/48 35.45
* 110 4m 3.2 11.07 100.4.40 GBWR 2/48 47.24
* 160 3m 3.3 28.70 100.6.30 G 1/33 91.87
* 160 4m 3.3 28.70 100.6.40 G 1/33 122.49

RING SEAL ADAPTOR Converts any Terrain solvent socket to a ring seal
expansion socket.
size(mm) A Code Col Pk/bx
:
:
A
82 21 109.3 GB 5/120 3.91

:
110 21 109.4 GBWR 5/180 3.82
160 26 109.6 G 5/60 10.29

STRAIGHT COUPLER Double solvent socket.


DOUBLE SOCKET size(mm) L Z Code Col Pk/bx
:
:
* 82 92 3 110.3 GBW 5/85 6.15

:
* 110 102 3 110.4 GBWR 5/60 7.69
L Z * 160 160 8 110.6 G /6 22.17

EXPANSION COUPLER To allow expansion in longer pipe runs.


size(mm) L Z Code Col Pk/bx
:
:
* 82 113 3 111.3 GBW 5/65 9.20

:
L Z * 110 123 3 111.4 GBW /10 9.40
* 160 210 8 111.6 G /3 28.31

SLIP COUPLER Double ring seal socket.


size(mm) L Code Col Pk/bx
:
:
* 82 134 111.S.3 G 5/30 19.11

:
L * 110 144 111.S.4 GB 5/20 23.93
* 160 210 111.S.6 G /5 61.27

SWEPT BEND (82mm) 921/2 and 135 as standard.


DOUBLE SOCKET (110mm) 921/2, 104, 1121/2 and 135 as standard.
size(mm) angle Z1 Z2 Code Col Pk/bx
:
:
* 82 921/2 102 98 101.3.92 GBW 5/40 15.44

:
Z2
* 110 921/2 75 83 101.4.92 GBWR /10 18.07
* 160 921/2 178 184 101.6.92 G /2 45.00
* 110 104 80 76 101.4.104 G 5/20 18.07

:
Z1
* 110 1121/2 65 63 101.4.112 GB 5/20 18.07

:
* 82 135 25 25 101.3.135 GBW 5/50 15.44

:
* 110 135 21 30 101.4.135 GBWR 5/30 18.07
* 160 135 44 44 101.6.135 G /4

2 * per metre is for estimating purposes only. G - Grey B - Black W - White R - Rustic Brown
100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
SPIGOT SOCKET BENDS Long tail. AVAILABLE AS SINGLE ITEMS
size(mm) angle Z1 Z2 Z2 Code Col Pk/bx

:
(max) (min)

:
Z2
* 82 921/2 41 152 97 107.3.92 G 5/40 14.94
* 110 921/2 57 197 110 107.4.92 GBW /10 17.51

Z1

size(mm) angle Z1 Z2 Z2 Code Col Pk/bx

:
(max) (min)
Z1

:
* 110 135 42 85 107.4.135 GBW /15 19.65
* 160 135 60 130 107P.6.135 G 1/8 46.65

Z2

VARIABLE BEND Adjustable 0-25.


SPIGOT/SOCKET size(mm) angle Z1 Z2 Code Col Pk/bx
:
Z1
* 110 0-25 45 110 107.4.025 G 5/25 33.93

:
Z2 Double spigot
* 110 0-25 45 110 101.4.025 G 5/20 33.79

SINGLE EQUAL BRANCH With boss connections.


TRIPLE SOCKET 104.3.92 2 boss horns
104.4.92 3 boss horns
Z3
104.4.924 4 boss horns
104.6.92 6 boss horns
Z1
Connect to boss horns using 117 boss adaptors
(see page 11)
Z2 size(mm) angle Z1 Z2 Z3 A Code Col Pk/bx
:
:
* 82 921/2 70 83 35 104.3.92 GBW 5/25 21.57

:
Z3
* 82 135 19 108 102 104.3.135 GB 5/25 21.57

:
* 110 921/2 82 82 54 104.4.92 GBWR 7 23.90

:
A
Z1 * 110 921/2 101 96 50 74 104.4.924 GBW 5/150 29.00
* 160 921/2 184 178 160 104.6.92 G 4/72 50.74

Z2

SINGLE EQUAL BRANCH No waste boss connections.


size(mm) angle Z1 Z2 Z3 Code Col Pk/bx

:
* 110 104 77 74 72 104.4.104 G 5/10 29.00
Z3 * 110 135 25 137 137 104.4.135 GBW /6 24.93
Z1
* 160 135 53 198198 (PUSH FIT) 104.6.135 G 3/54 96.84
Z2

G - Grey B - Black W - White R - Rustic Brown 3


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
SINGLE BRANCH With boss connections. AVAILABLE AS SINGLE ITEMS
SPIGOT OUTLET 4 boss horns.
size(mm) angle A Z1 Z2 Z3 Code Col Pk/bx
:
Z3
110 921/2 74 103 96 50 104.104.92 GB /4 31.14
A
Z1

Z2

SINGLE EQUAL BRANCH 2 boss horns


VARIABLE BOSS 2 waste sockets.
Z2 Spigot outlet
size(mm) angle A B Z1 Z2 Z3 Code Col Pk/bx
Z3
110 921/2 142 140 91 83 59 : 104.412.92 G /4 53.96
Z1 A
Socket outlet
B size(mm) angle A B Z1 Z2 Z3 Code Col Pk/bx
110 921/2 142 140 91 83 59 : 104.422.92 G /3 53.96

SINGLE UNEQUAL BRANCH 2 boss horns.


TRIPLE SOCKET size(mm) angle Z1 Z2 Z3 Code Col Pk/bx
Z2
160/110 921/2 59 87 62 : 104.64.92 G /3 57.29

Z3
Z1

No waste boss connections.


size(mm) angle Z1 Z2 Z3 Code Col Pk/bx

Z3
160/110 135 70 173 164 : 104.64.135 G /2 61.57

Z1
Z2

CORNER BRANCH 1 boss horn.


TRIPLE SOCKET size(mm) angle Z1 Z2 Z3 Code Col Pk/bx
110 921/2 94 83 59 : 106.490.92 G 5 104.32
Z3

Z1

Z2

4 G - Grey B - Black W - White R - Rustic Brown


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
CORNER BOSS BRANCH 1 boss horn. 2 waste sockets. AVAILABLE AS SINGLE ITEMS
Z1 Spigot outlet
size(mm) angle A Z1 Z2 Code Col Pk/bx
Z2
110 921/2 120 83 59 106.490.12 G 7/126 118.68

A Socket outlet
size(mm) angle A Z1 Z2 Code Col Pk/bx
110 921/2 120 83 59 : 106.490.22 G /3 118.68

DOUBLE BRANCH 4 boss horns.


Spigot outlet
Z3 size(mm) angle A B Z1 Z2 Z3 Code Col Pk/bx
A
Z1
110 921/2 75 128 203 96 50 106.104.92 G 2/60 59.07
B

Z2

4 boss horns.
Z3 Socket outlet
A
Z1 size(mm) angle A B Z1 Z2 Z3 Code Col Pk/bx
110 921/2 74 138 95 50 : 106.4.92 GBW 2/60 59.07
Z2
No bosses.
size(mm) angle A B Z1 Z2 Z3 Code Col Pk/bx
110 135 25 137 137 : 106.4.135 G /3 61.74

DOUBLE UNEQUAL BRANCH 2 boss horns.


Z2 size(mm) angle Z1 Z2 Z3 Code Col Pk/bx
160/110 921/2 59 87 62 : 106.64.92 G /2 106.71

Z3
Z1

ACCESS PIPE size(mm) L Z Code Col Pk/bx


DOUBLE SOCKET 110 216 115 : 138.4 GBWR /10 25.35

Z L

ACCESS PIPE size(mm) L Z Code Col Pk/bx


SPIGOT OUTLET 110 216 166 : 139.4 GB /10 25.35

L
Z

G - Grey B - Black W - White R - Rustic Brown 5


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
ACCESS PIPE CONNECTOR 2 boss horns. AVAILABLE AS SINGLE ITEMS
size(mm) A B Z Code Col Pk/bx

A
82 41 39 120 : 137.3 GBW 5/25 37.79

Z
B

4 boss horns.
size(mm) A B Z Code Col Pk/bx
:
A

Z 110 41 35 149 137.4 GBW 5/15 38.39

ACCESS BEND size(mm) angle Z1 Z2 Code Col Pk/bx


DOUBLE SOCKET 110 921/2 102 98 : 103.4.92 GBW 5/15 50.12
Z2

Z1

SINGLE ACCESS BRANCH 4 boss horns.


TRIPLE SOCKET size(mm) angle Z1 Z2 Z3 Code Col Pk/bx
110 921/2 99 96 50 : 105.4.92 GB /6 40.92
Z3
Z1
Z3

Z2

ACCESS DOOR size(mm) L hole saw Code Col Pk/bx


:
:
82 114 48 135.3 G 5/90

:
110 152 73 135.4 GB 5/45 20.55
160 152 73 135.6 G 5/50 36.72
L

ACCESS CAP size(mm) A Z1 Z2 Code Col Pk/bx


:
:
82 83 16 32 136.3 GW 5/70 14.55

:
Z1 110 97 21 46 136.4 GBWR 5/30 17.15
Z2 160 122 22 42 136.6 G 5/35 32.28
A

ACCESS DOOR WITH Standard oval access door with test nipple for
TEST NIPPLE manometer connection.

A A Code Col Pk/bx


127 6592/DVW GBWR 1 POA

6 G - Grey B - Black W - White R - Rustic Brown


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
THERMAL MOVEMENT AVAILABLE AS SINGLE ITEMS
LIMITER size(mm) A B C Code Col Pk/bx
:
:
82 100 129 154 190.3 Self 1/20 29.76

:
A
110 100 158 178 190.4 Self 5/15 32.38
160 100 232 260 190.6 Self 1/5 51.33
C B

INTERMEDIATE SUPPORT To support horizontal pipework.


BRACKET size(mm) A B C Code Col Pk/bx

:
82 100 129 154 191.3 Self 1/30 15.15
A
110 100 158 178 191.4 Self 1/20 16.47
160 100 232 260 191.6 Self /10 22.04
CB

TWO-PIECE PIPE BRACKET Galvanised steel


size(mm) A B C D Code Col Pk/bx
:
:
82 140 114 76 124 140.3 Self 10/40 4.80

:
AB
110 175 147 89 152 140.4 Self 10/30 4.99
160 216 196 114 197 140.6 Self 5/25 12.01
C
D

ONE-PIECE PIPE BRACKET size(mm) A B C D Code Col Pk/bx


:
:
82 132 110 76 117 143.3 GBW 5/150 3.57
110 164 141 90 155 143.4 GBWR 10/80 3.34
A B

D
C

ADJUSTABLE PIPE BRACKET Both have self coloured backplates.


PLASTIC-COATED size(mm) A B C C Code Col Pk/bx
(max) (min)

:
C

110 99 64 108 80 144.4 B 1/30 6.78


A B

PIPE BRACKET size(mm) A B C Code Col Pk/bx


GALVANISED DRIVE-IN 110 178 152 59 142.4 Self 10/20 10.37

G - Grey B - Black W - White R - Rustic Brown 7


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
WEATHERING APRON Makes weathertight cover between soil pipe and lead AVAILABLE AS SINGLE ITEMS
slate at roof level.
For lead slates
B size(mm) A B Code Col Pk/bx
:
:
A 82 102 38 131.3 GB 5/60 4.35

:
110 128 48 131.4 GBWR 5/90 4.99
160 179 51 131.6 G 5/50 15.02
For asphalt upstand

D size(mm) C D Code Col Pk/bx


C 82 204 59 131.3.200 G 5/35 18.36
110 203 46 131.4.200 G 5/30 18.36

WEATHERING SLATES Makes watertight seal around pipe at roof level.


Available for flat or pitched roof.

Colours: Base Aluminium


Cone Black
For flat roof
size(mm) Plate size Code Col Pk/bx
82 to 110 406 x 406 : 149.16.00 Alu/B /10 51.74
For sloping roof (min 30)
size(mm) Plate size Code Col Pk/bx
82 to 110 457 x 457 149.18.22 Alu/B 1/10 53.05
For sloping roof (min 17)
size(mm) Plate size Code Col Pk/bx
82 to 110 610 x 610 : 149.24.22 Alu/B 1/10 71.69

VENT COWL size(mm) A Code Col Pk/bx


:
:
82 51 150.3 GB 5/120 4.35

:
110 64 150.4 GBWR 5/185 4.40
A 160 83 150.6 G 5/65 11.51

DUCT COWL Stops rainwater from entering ventilation ducts.


size(mm) A L Code Col Pk/bx
:
L
110 205 80 152.4 GBR 5/25 19.71

AUTOMATIC AIR Allows air to enter soil system, protecting water seals in
ADMITTANCE VALVE traps from effects of negative pressure.
size(mm) A B L Code Col Pk/bx
:
A
82/110 160 50 138 153.3.4 G 5/15
L
Polystyrene Cover 153.3.4I Self 1 1.88
B

8 G - Grey B - Black W - White R - Rustic Brown


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
TWO PART WASTE BOSS For 32mm waste pipe AVAILABLE AS SINGLE ITEMS
SOLVENT SOCKET size(mm) A Z hole saw Code Col Pk/bx
A
Z 110/32 79 53 48 112.4.125 G 5/200 8.44
For 40mm waste pipe
size(mm) A Z hole saw Code Col Pk/bx
82/40 69 39 57 112.3.15 G 5/150 8.44
110/40 82 53 57 112.4.15 G 5/150 8.44
For 50mm waste pipe
size(mm) A Z hole saw Code Col Pk/bx

:
110/50 86 53 70 112.4.2 GW 5/100 8.76
160/50 110 77 70 112.6.2 G 5/100 11.95

SOCKET PLUG size(mm) L Code Col Pk/bx


110 69 130.4 GBW 5/50 10.61
160 92 130.6 G 5/35 19.49

SELF LOCKING BOSS For 32mm waste pipe


SEAL RING SOCKET size(mm) A Z hole saw Code Col Pk/bx
A
110/32 111 60 60 : 122.4.125 GW 5/130 11.28
For 40mm waste pipe
size(mm) A Z hole saw Code Col Pk/bx
110/40 111 60 64 : 122.4.15 GB 5/100 11.78
Z For 50mm waste pipe
size(mm) A Z hole saw Code Col Pk/bx
110/50 119 60 75 : 122.4.2 GBW 5/60 15.22

SINGLE BOSSED PIPE For 32mm waste pipe


CONNECTOR size(mm) Z1 Z2 Z3 Code Col Pk/bx
:
DOUBLE SOCKET
110/32 30 56 31 120.4.125 GBWR 5/30 6.46
For 40mm waste pipe
Z3
size(mm) Z1 Z2 Z3 Code Col Pk/bx
:
Z1

110/40 30 56 31 120.4.15 GBWR 5/30 6.46

Z2 For 50mm waste pipe


size(mm) Z1 Z2 Z3 Code Col Pk/bx
110/50 30 59 31 : 123.4 GBW 5/30 6.81

SINGLE BOSSED PIPE For 40mm waste pipe


CONNECTOR SPIGOT size(mm) Z1 Z2 Z3 Code Col Pk/bx
110/40 28 56 27 : 120.412.15 GR 5/30 6.27
Z3
Z1

Z2

G - Grey B - Black W - White R - Rustic Brown 9


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
DOUBLE BOSSED PIPE 2 50mm waste sockets AVAILABLE AS SINGLE ITEMS
CONNECTOR DOUBLE SOCKET 2 blanking plugs
Z1 For 50mm waste pipes (40mm with adaptor)
Z2
size(mm) Z1 Z2 Z3 Code Col Pk/bx
82/50 50 38 65 : 120.3.2 GB 5/30 12.97
Z3

TRIPLE BOSSED PIPE size(mm) Z1 Z2 Z3 Code Col Pk/bx


CONNECTOR DOUBLE SOCKET 110/40 30 56 30 : 121.4.15 GB 5/25 10.48

Z3
Z1

Z2

120 120
A B A B

90 90
150 150
C C

FOUR-WAY BOSS PIPE 2 boss horns, 2 waste sockets.


DOUBLE SOLVENT SOCKET size(mm) Z1 Z2 Z3 Z4 Z5 Code Col Pk/bx
110 44 40 56 55 59 120.4.2 G 5/9 10.48
Z2
Z5 Z3
Z1

Z4

FOUR-WAY BOSS PIPE 2 boss horns, 2 waste sockets.


SOLVENT SOCKET/SPIGOT size(mm) Z1 Z2 Z3 Z4 Z5 Code Col Pk/bx
110 44 40 56 55 59 120.412.2 G 5/9 10.48
Z2
Z5 Z3
Z1

Z4

UNIVERSAL SOIL MANIFOLD For Solvent waste connections


L3 For connection of BS 5254/BS 5255 40mm waste pipes
98 at floor level. Incorporates 4 inlets to accept 40mm
waste pipes without need for adaptors. Use with Swivel
Elbow or Swept Bend.
L1 L2Z1
For Pushfit waste connections see page 18
size(mm) L1 L2 L3 L4 Z1 Code Col Pk/bx
L3
110 228 189 199 217 105 119.412.15 G 1/5 32.29

L4

SOCKET REDUCER size(mm) A Z Code Col Pk/bx


:
:
SOCKET/SPIGOT 82/50 11 3 124.3.2 GW 5/90 9.35

:
110/50 24 3 124.4.2 GBW 5/60 11.66

:
110/82 11 3 124.4.3 GBW 5/60 12.01
A 160/110 22 25 124.6.4 G 5/45 24.35

10 G - Grey B - Black W - White R - Rustic Brown


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
STRAIGHT BOSS ADAPTOR For 32mm waste pipe AVAILABLE AS SINGLE ITEMS
RING SEAL SOCKET use on
stack
size(mm) A Z hole saw Code Col Pk/bx
82 107 61 51 117.125 GBW 5/180 3.36
110 119 74 51 117.125 GBW 5/180 3.36
160 144 99 51 117.125 GBW 5/180 3.36
For 40mm waste pipe
use on
stack
size(mm) A Z hole saw Code Col Pk/bx
82 107 61 51 117.15 GBWR 5/160 3.36
110 119 74 51 117.15 GBWR 5/160 3.36
160 144 99 51 117.15 GBWR 5/160 3.36
Z
For 50mm waste pipe
A
use on
stack
size(mm) A Z hole saw Code Col Pk/bx
82 107 61 51 117.2 GBW 5/120 4.79
110 119 74 51 117.2 GBW 5/120 4.79
160 144 99 51 117.2 GBW 5/120 4.79

BOSS ADAPTOR BEND For 40mm waste pipe


SOLVENT SOCKET use on
stack
size(mm) A Z1 Z2 hole saw Code Col Pk/bx
82 106 82 22 51 117.15.90 GBW 5/125 5.01
110 119 95 22 51 117.15.90 GBW 5/125 5.01
160 145 121 22 51 117.15.90 GBW 5/125 5.01

A
For 50mm waste pipe
use on
stack
Z2 size(mm) A Z1 Z2 hole saw Code Col Pk/bx
82 120 89 30 51 117.2.90 GBW 5/190 6.01
110 132 101 30 51 117.2.90 GBW 5/190 6.01
Z2 160 158 127 30 51 117.2.90 GBW 5/190 6.01
82 80 11 51 117.2.150 G 5/190 5.24
110 92 11 51 117.2.150 G 5/190 5.24
160 118 11 51 117.2.150 G 5/190 5.24
Z1

ADAPTOR TO Push fit into bore of underground pipe.


UNDERGROUND DRAIN size(mm) L Code Col Pk/bx
82/110 54 4DW3 B 5/50 15.17

Note: As a Terrain Underground product different


discount structure applies.

ADAPTOR TO CAST IRON size(mm) A B Z1 Code Col Pk/bx


SPIGOT 82 60 98 240 126.3.12 G 5/30
B 110 64 127 236 126.4.12 G 5/15 14.66

Z1

G - Grey B - Black W - White R - Rustic Brown 11


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
ADAPTOR SADDLES Used with 117 Waste Adaptors to enable direct AVAILABLE AS SINGLE ITEMS
connection of 32mm and 40mm waste pipe to
soil pipe.
For 40mm waste pipe
size(mm) Z1 Code Col Pk/bx
Z1 110/40 29 115P.4 GR 5/140

PVC-U CAULKING BUSH To connect soil pipe to sockets of other material. Sold
caulked into sockets.
C size(mm) A B C Z Code Col Pk/bx
Z 110 133 124 63 67 132.4 G 5/40 14.44

B
A

WC MANIFOLD CONNECTORS When used in conjunction with a branch 104, up to


FIN SEAL SPIGOT seven WC pans can be connected either side of the soil
stack.
Z1
Z2
size(mm) angle Z1 Z2 Code Col Pk/bx
:
:
110 5 14 58 129.4.05 W /6 23.46

:
110 14 19 58 129.4.14 W /6 23.46

:
110 24 24 58 129.4.24 W 5/10 23.46
110 34 26 70 129.4.34 W 5/10 23.46

DUOFIX WC MANIFOLD size(mm) angle Z1 Z2 Code Col Pk/bx


BEND CONNECTORS 90/110 5 52 65 107.35.05 B 5/10 21.72
FIN SEAL SPIGOT 90/110 14 57 63 107.35.14 B 5/10 21.72
Z1 90/110 24 60 70 107.35.24 B 5/10 21.72
Z2
90/110 34 64 78 107.35.34 B 5/10 21.72
90/110 9 6.4 62.3 F107.35.09 B 1/24 21.72
90/110 18 11.3 67.4 F107.35.18 B 1/12 21.72
90/110 29 18.3 77.3 F107.35.29 B 1/12 21.72

WC CONNECTORS size(mm) Z1 Z2 Z2 Code Col Pk/bx

:
14 FIN SEAL SPIGOTS (max) (min)

Z1 110 19 90 57 129.4.104 W 5/30 14.49


Z2

WC CONNECTORS For connection of WC pans to existing soil or waste


SPIGOT OUTLET pipework previously connected to traditional S mode
pan.
Z1
size(mm) angle L Z1 Z2 Code Col Pk/bx
110 98 150 63 240 129.4.90 W /5 19.89

Z2

12 G - Grey B - Black W - White R - Rustic Brown


100-Solvent
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
WC CONNECTORS AVAILABLE AS SINGLE ITEMS
SOCKET OUTLET size(mm) angle L Z1 Code Col Pk/bx
Z1
110 21/2 101 12 : 128.4.02 W 5/50 10.92

L
Z1 size(mm) angle L Z1 Z2 Code Col Pk/bx
110 90 155 61 55 : 128.4.90 W 5/25 17.55
Z2

90 WC TURNED CONNECTOR For connecting non-BS 5503 WC pans to soil pipe.


SOCKET OUTLET size(mm) angle A B L Z1 Z2 Code Col Pk/bx
B
110 921/2 72 133 207 52 72 : 102.4.5 W 5/20 28.04
A

Z2 L

Z1

WC STRAIGHT CONNECTOR For connecting non-BS 5503 WC pans to soil pipe.


SOCKET OUTLET size(mm) A B Z1 Code Col Pk/bx
B
110 52 133 12 : 125.4.5 W 5/25 17.08

Z1

WC VARIABLE CONNECTOR Adjustable 0-25.


VARIABLE BEND size(mm) angle Z1 Z2 Code Col Pk/bx
Z1
Z2 110 0-25 45 86 : 128.4.025 W 5/25 34.83

G - Grey B - Black W - White R - Rustic Brown 13


100P-PushFit
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
SOIL PIPE AVAILABLE AS SINGLE ITEMS
SINGLE SOCKET-ENDED size(mm) L1 T Code Col Pk/St
(min)

82 3m 3.2 9.12 100P.3.30 G 1/88 30.67


82 4m 3.2 9.11 100P.3.40 G 1/88 40.80
L1 110 3m 3.2 9.20 100P.4.30 GBW 2/67 30.91
110 4m 3.2 9.20 100P.4.40 GBW 2/67 41.22
160 3m 3.3 24.70 100P.6.30 G 1/33 83.03
160 4m 3.3 24.72 100P.6.40 G 1/33 110.75

SLIP COUPLER size(mm) Code Col Pk/bx


DOUBLE SOCKET 110 111.SP4 G 5/40 13.07

STRAIGHT COUPLER With central stop.


DOUBLE SOCKET size(mm) L Z Code Col Pk/bx
82 103 6 110P.3 G 5/30 11.81
110 129 6 110P.4 GBW 5/40 10.73
L 160 188 10 110P.6 G /5 25.36
Z

PIPE END SOCKET size(mm) L1 L2 Z Code Col Pk/bx


SPIGOT/SOCKET 82 91 39 4 111P.3 G 5/60 6.69
110 107 48 3 111P.4 GBW /20 7.51

L1 Z
L2

SWEPT BEND size(mm) angle L1 Z1 Z2 Code Col Pk/bx


SPIGOT/SOCKET 82 921/2 149 109 161 101P.3.92 G 5/25
110 921/2 142 85 145 101P.4.92 GBW /10 16.11
160 921/2 215 135 215 101P.6.92 G 1/4 48.36
L1
Z1 110 1121/2 152 104 184 101P.4.112 G /10 18.01
82 135 76 36 89 107P.3.135 G 5/40 13.17
110 135 89 42 119 107P.4.135 GBW /15 16.26
Z2
160 135 140 60 130 107P.6.135 G 1/8 46.65

TIGHT RADIUS BEND size(mm) angle L1 Z1 Z2 Code Col Pk/bx


SPIGOT/SOCKET 110 921/2 113 65 197 107P.4.92 G /10 16.27

L1
Z1

Z2

14 * per metre is for estimating purposes only. G - Grey B - Black W - White R - Rustic Brown
100P-PushFit
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
OFFSET BEND Top AVAILABLE AS SINGLE ITEMS
size(mm) L1 L2 Z1 Z2 Code Col Pk/bx
L1 110 119 73 71 54 101P.4T.112 GB 5/25 21.14
Z1

Z2
L2

L1 Bottom
Z1
size(mm) L1 Z1 Z2 Code Col Pk/bx
110 73 54 127 101P.4B.112 GB 5/20 21.14
Z2

SINGLE BRANCH With spigot bosses.


SPIGOT OUTLET
2 boss horns.
size(mm) angle L1 L2 Z1 Z2 Z3 Code Col Pk/bx
Z1
L1
82 921/2 225 125 54 85 131 104P.3.92 G 5/15 23.50
Z3 Z2
L2

5 boss horns.
Z1 A size(mm) angle L1 L2 Z1 Z2 Z3 A B Code Col Pk/bx
L1 B
110 921/2 278 152 58 96 164 19 57 104P.4.92 GBW 8 21.73
Z3
Z2 160 921/2 440 242 90 155 260 104P.6.92 G 1/4 56.03
L2

size(mm) angle L1 L2 Z1 Z2 Z3 Code Col Pk/bx

Z1 110 1121/2 349 165 95 95 184 104P.4.112 G 1/5 30.71


L1

Z3
Z3
L2

SINGLE EQUAL BRANCH No boss connections.


PLAIN size(mm) angle L1 L2 Z1 Z2 Z3 Code Col Pk/bx
110 135 328 215 168 168 113 104P.4.135 G /6 22.37

Z1
L1
Z2
L2
Z3

DOUBLE EQUAL BRANCH 4 boss connections.


SPIGOT OUTLET size(mm) angle L1 L2 Z1 Z2 Z3 Code Col Pk/bx
110 921/2 287 172 66 124 173 106P.4.92 GB /2 56.89
Z1
L1
Z2 Z3
L2

G - Grey B - Black W - White R - Rustic Brown 15


100P-PushFit
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
ACCESS PIPE AND COVER AVAILABLE AS SINGLE ITEMS
SINGLE SOCKET size(mm) L1 L2 Z1 Code Col Pk/bx
82 193 97 153 139P.3 G /10 29.44

L1
Z1
L2

size(mm) L1 L2 Z1 Code Col Pk/bx


110 222 114 175 139P.4 GB /10
L1
Z1

L2

Access door aperture size:


172 x 130mm diameter secured by 2 screws.
L1 Z1 size(mm) L1 L2 Z1 Code Col Pk/bx
L2
160 366 198 305 139P.6 G 1/5 61.70

ACCESS BEND Access door aperture size:


SINGLE SOCKET 110 x 80mm diameter secured by locking mechanism
(use self tapping screw for anti-vandal locking).
L1
size(mm) angle L1 L2 Z1 Z2 Code Col Pk/bx
110 921/2 41 69 91 157 103P.4.92 GB 5/15 44.36
L2
Z2

Z1

ACCESS SINGLE EQUAL With waste bosses.


BRANCH SINGLE OUTLET 4 boss horns.

Access door aperture size:


114 x 80mm diameter secured by locking mechanism
L1 L2 (use self tapping screw for anti-vandal locking).
Z1
Z3 size(mm) L1 L2 Z1 Z2 Z3 Code Col Pk/bx
Z2
110 136 74 87 105 172 105P.4.92 G /4 50.99

ACCESS DOOR WITH Standard oval access door with test nipple for
TEST NIPPLE manometer connection.
A A Code Col Pk/bx
127 6592/DVW GBWR 1 POA

ACCESS CAP size(mm) A Z1 Z2 Code Col Pk/bx


82 81 26 13 136P.3 G 5/40 11.99
Z1 110 102 34 10 136P.4 GBW 5/40 14.14
Z2 160 134 34 10 136P.6 G 1/15 33.23
A

16 G - Grey B - Black W - White R - Rustic Brown


100P-PushFit
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
STRAP-ON BOSS For 32mm waste pipe AVAILABLE AS SINGLE ITEMS
Code Col Pk/bx
size(mm) L1 hole saw
110/32 116 60 Part No. 9105.237 112P.4.125 GBW 5/100 7.17
L1
For 40mm waste pipe
Code Col Pk/bx
size(mm) L1 hole saw
NEW!
110/40 116 60 Part No. 9105.237 112P.4.15 GBW 5/90
Now allows back-to-back
dual connection of similar For 50mm waste pipe
and/or dissimilar pipe Code Col Pk/bx
diameters size(mm) L1 hole saw
110/50 120 60 Part No. 9105.237 112P.4.2 GB 5/85 7.24

BOSS ADAPTORS STRAIGHT For 32mm waste pipe


use on
stack
size(mm) A Z hole saw Code Col Pk/bx
82 107 61 51 117.125 GBW 5/180 3.36
110 119 74 51 117.125 GBW 5/180 3.36
160 144 99 51 117.125 GBW 5/180 3.36
For 40mm waste pipe
use on
stack
size(mm) A Z hole saw Code Col Pk/bx
82 107 61 51 117.15 GBWR 5/160 3.36
110 119 74 51 117.15 GBWR 5/160 3.36
Z 160 144 99 51 117.15 GBWR 5/160 3.36
A
For 50mm waste pipe
use on
stack
size(mm) A Z hole saw Code Col Pk/bx
82 107 61 51 117.2 GBW 5/120 4.79
110 119 74 51 117.2 GBW 5/120 4.79
160 144 99 51 117.2 GBW 5/120 4.79

ADAPTOR SADDLES For 40mm waste pipe


size(mm) Z1 hole saw Code Col Pk/bx
110/40 29 51 115P.4 G 5/140 6.94

Z1

REDUCERS size(mm) L1 L2 Z1 Code Col Pk/bx


82/50 117 44 15 124P.3.2 G 5/60
L2 110/50 136 45 16 124P.4.2 GB 5/50 15.36
Z1 110/82 140 55 18 124P.4.3 G 5/40 15.36
L1
160/110 233 75 44 124P.6.4 G 5/15 22.14

SHORT BOSSED PIPE size(mm) L1 Z1 Z2 Code Col Pk/bx


82 145 48 97 123P.3 G 5/20 8.71
110 212 43 110 123P.4 GB /10 8.80
Z1

L1
Z2

G - Grey B - Black W - White R - Rustic Brown 17


100P-PushFit
Terrain
TerrainSoil Systems
Soil Systems
COLOUR CODES IN BOLD
FOUR-WAY BOSS PIPE 2 boss horns. AVAILABLE AS SINGLE ITEMS
PUSH-FIT SOCKET/SPIGOT size(mm) Z1 Z2 Z3 Z4 Z5 Code Col Pk/bx
110 44 40 56 55 59 120P.412.2 G 5/15 11.34
Z2
Z5 Z3
Z1

Z4

TRIPLE BOSS COLLAR


size(mm) L1 L2 Z1 Code Col Pk/bx

Z1 L1 110/40 65 95 125 120P.4.15 GB 5/30 8.80

L2

SOCKET PLUG size(mm) L Code Col Pk/bx


110 69 130.4 GBW 5/50 10.61
160 92 130.6 G 5/35 19.49

UNIVERSAL SOIL MANIFOLD For Pushfit waste connections


L3
For connection of BS 5254/BS 5255 32mm and 40mm
98 waste pipes at floor level. Incorporates 4 inlets to
accept 32mm or 40mm waste pipes without need for
adaptors. Use with Swivel Elbow or Swept Bend.
L1 L2Z1 Complete with 4 sealing gaskets, and 3 removable
plugs.

For Solvent waste connections see page 10


L3
size(mm) L1 L2 L3 L4 Z1 Code Col Pk/bx
110 228 189 199 217 105 119P.4.15 G /5 32.74
L4

WC CONNECTOR size(mm) L Z1 Z2 Code Col Pk/bx


STRAIGHT FIN SEAL 110 125 10 56 129P.4.00 W 5/40 13.16
L

Z2 Z1

WC CONNECTOR size(mm) angle Z1 Z2 Code Col Pk/bx


90 FIN SEAL BEND 110 90 230 60 129P.4.90 W /5 13.15
Z2

90

Z1
Full range of WC Connectors available, page 1213.

For pipe brackets see page 7.

18 G - Grey B - Black W - White R - Rustic Brown


200-Solvent
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
WASTE PIPE Plain-ended. AVAILABLE AS SINGLE ITEMS
size(mm) L T Code Col Pk/bx

:
(min)

:
L 32 3m 1.8 2.44 200.125.30 GW 5 7.68

:
32 4m 1.8 2.44 200.125.40 GBWR 5 10.23

:
40 3m 1.9 3.02 200.15.30 GW 5 9.50

:
40 4m 1.9 3.02 200.15.40 GBWR 5 12.66

:
50 3m 2.0 4.54 200.2.30 W 5 14.31
T
50 4m 2.0 4.55 200.2.40 GBW 5 19.09

SEAL RING ADAPTOR To convert 50mm 207.2 spigot socket bends to


expansion fitting.

A
size(mm) A Code Col Pk/bx
50 65 209.2 GW 5/250 3.68

STRAIGHT COUPLER size(mm) L Z Code Col Pk/bx


:
:
DOUBLE SOCKET 32 52 2 210.125 GBWR 10/350 1.60
Z 40 58 2 210.15 GBWR 5/240 1.59
50 65 2 210.2 GBW 10/140 2.91

UNION DOUBLE SOCKET Threaded union for easy disconnection if required.


Z size(mm) L Z Code Col Pk/bx
:
:
32 59 8 211.125 G 5/200 6.68
40 65 8 211.15 G 5/130 8.75
50 73 8 211.2 G 5/90 9.97

EXPANSION COUPLER size(mm) L Z Code Col Pk/bx


:
:
SEAL RING AND 32 67 4 225.125 GW 10/240 2.81
SOLVENT SOCKET 40 70 4 225.15 GW 10/180 3.39
Z 50 77 4 225.2 GW 5/100 4.59

SPIGOT/SOCKET COUPLER To create a close-coupled expansion joint for all MuPVC


fittings.
Z
size(mm) Z Code Col Pk/bx
:
:
32 27 227.125 GW 5/250 2.81

:
40 30 227.15 GW 5/180 3.39
50 35* 227.2 G 5/100 4.59
*dimension includes expansion

* per metre is for estimating purposes only. G - Grey B - Black W - White R - Rustic Brown 19
200-Solvent
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
SWEPT BEND 911/4, 135 and 165 as standard. AVAILABLE AS SINGLE ITEMS
DOUBLE SOCKET For 911/4 swept bend
size(mm) angle Z1 Z2 Code Col Pk/bx
:
:
Z2 32 911/4 34 34 201.125.91 GBWR 20/220 1.62

:
40 911/4 38 38 201.15.91 GBWR 5/140 1.81
50 911/4 45 45 201.2.91 GBW 5/70 3.18
Z1

For 135 swept bend


size(mm) angle Z1 Z2 Code Col Pk/bx
:
Z2

:
32 135 10 10 201.125.135 GBWR 10/280 1.62

:
Z1 40 135 11 11 201.15.135 GBWR 5/200 1.81
50 135 14 14 201.2.135 GBW 5/100 3.18
For 165 swept bend
size(mm) angle Z1 Z2 Code Col Pk/bx
:
:
Z2
32 165 5 5 201.125.165 G 10/320 2.46

:
Z1
40 165 5 5 201.15.165 G 5/220 3.19
50 165 6 6 201.2.165 G 5/250 4.20

SPIGOT/SOCKET BENDS To change pipe direction in limited-space situations:


921/2 and 150 as standard.
size(mm) angle Z1 Z2 Z2 Code Col Pk/bx
Z2

:
(max) (min)

:
32 921/2 19 92 46 207.125.92 GBW 5/180 2.66

:
40 921/2 21 95 52 207.15.92 GBW 5/120 3.05

:
50 921/2 29 102 64 207.2.92 GW 5/60 4.33

:
Z1 32 135 8 30 207.125.135 W 5/300 2.64

:
40 135 11 38 207.15.135 GBW 5/180 3.04

:
50 135 13 46 207.2.135 GW 5/100 4.41

:
32 150 8 52 29 207.125.150 GB 10/260 2.75
40 150 9 49 33 207.15.150 GB 5/200 3.14

KNUCKLE BEND size(mm) angle Z1 Z2 Code Col Pk/bx


:
:
DOUBLE SOCKET 32 911/4 19 19 202.125.91 GBWR 10/280 1.48
40 911/4 22 22 202.15.91 GBWR 10/200 1.63

Z2

Z1

SWEPT CROSS size(mm) angle Z1 Z2 Z3 Code Col Pk/bx


ALL SOCKET 40 911/4 44 44 20 206.15.91 GW 5/105 6.71
50 911/4 51 51 25 206.2.91 GW 5/55 7.03
Z3 50 135 13 71 71 206.2.135 G 5/55 45.98

Z1

Z2

SWEPT TEE 911/4 and 135 as standard.


ALL SOCKET size(mm) angle Z1 Z2 Z3 Code Col Pk/bx
:
:
32 911/4 30 30 19 204.125.91 GBWR 5/120 2.18

:
Z3 40 911/4 32 35 22 204.15.91 GBWR 5/90 2.76

:
Z1 50 911/4 43 43 29 204.2.91 GBW 5/45 5.39

:
32 135 8 48 48 204.125.135 GW 5/120 2.61

:
40 135 10 57 57 204.15.135 GW 5/80 3.45
50 135 13 71 71 204.2.135 GBW 5/80
Z2

20 G - Grey B - Black W - White R - Rustic Brown


200-Solvent
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
LEVEL INVERT TAPER To reduce socket of any standard fitting to accept a AVAILABLE AS SINGLE ITEMS
smaller size pipe. Larger end spigot and smaller end
Z
socket.
size(mm) A L Z Code Col Pk/bx
A centres
:
:
40/32 4 73 47 223.15.125 G 5/230 1.99

:
L 50/32 10 98 73 223.2.125 GW 10/190 2.47
50/40 7 90 62 223.2.15 G 10/160 2.46

SOCKET REDUCER size(mm) A Z Code Col Pk/bx


centres
Z
40/32 0 3 224.15.125 GBWR 20/640 1.60
50/32 7 6 224.2.125 GBW 10/350 2.31
50/40 4 3 224.2.15 GBW 10/350 2.82
A

PIPE FIXING CLIP size(mm) A B Code Col Pk/bx


:
:
32 33 54 240.125 GBWR 20/10000.52

:
40 37 60 240.15 GBWR 20/800 0.60
A 50 43 76 240.2 GBW 10/500 0.80

EXPANSION FITTING To secure control thermal expansion at regular points


FIXING CLIP along pipework.
size(mm) A Code Col Pk/bx
:
:
32 33 242.125 GW 10/750 0.63

:
A 40 37 242.15 W 10/500 0.71
50 43 242.2 GW 10/300 1.53

PIPE AND FITTING BRACKET size(mm) A B Code Col Pk/bx


:
:
(METAL) 32 57 44 243.125 Self 10/120 2.29

:
40 60 48 243.15 Self 10/100 2.73
50 75 53 243.2 Self 10/70 3.47
A

ACCESS PLUG size(mm) L Code Col Pk/bx


:
:
32 47 237.125 GBW 10/350 1.48
L

:
40 54 237.15 GBW 10/320 1.48
50 56 237.2 GBW 5/180 2.13

WEATHERING APRON To provide weathertight cover over lead slate around


50mm waste pipe penetrating roof.
size(mm) A B Code Col Pk/bx
B 50 76 38 : 231.2 G 5/135 3.38

G - Grey B - Black W - White R - Rustic Brown 21


200-Solvent
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
VENT COWL AVAILABLE AS SINGLE ITEMS
size(mm) A Code Col Pk/bx
50 34 : 250.2 GW 5/300 3.84
A

AUTOMATIC AIR Allows air into waste system when negative pressure
ADMITTANCE VALVE occurs. Helps prevent syphonage of traps.
size(mm) A B L L1 C D Code Col Pk/bx
:
A

32/40/50 65 26 80 55 25 25 253W W 5/70 20.36

C
L1
D

TRAPPED FLOOR GULLY Under-floor trap (e.g. for shower areas) with 3 sockets
to accept 40mm waste pipe.
H
Seal depth: 50mm.
B Cleaning access via removable baffle with integral
EF C
A gasket to maintain airtight seal.
G
D
size(mm) A B C D E F G H Code Col Bx
110/82 169 69 77 64 51 42 82 110 281.43 GT 2/20 21.22
160/110 169 70 85 69 55 50 110 160 281.64 GT 1/12 21.22

FLOOR GULLY INLETS Two-part fitting to be set in standard-tiled floor


(e.g. in shower areas). Comprises of raising piece with
A
50mm square top, and snap-in cover.
Z1
size(mm) A B Z1 Z2 Code Col Bx
:
Z2

:
110 PVC 50x150 110 14 48 282.6 GW 1/36 7.70
110 SS 50x150 110 14 48 283.6 Self 1/36 15.58
B

SEALED GULLY size(mm) Code Col Bx


RAISING PIECE 110 284.6 GW 1/36 9.43

SEALED GULLY size(mm) Code Col Bx


RAISING PIECE 110 285.6 Self 1/36 15.94
STAINLESS STEEL COVER

22 G - Grey B - Black W - White R - Rustic Brown T - Terracotta


200-Solvent
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
ADAPTOR TO UNDERGROUND Push-fit connection into pipes with nominal 100mm AVAILABLE AS SINGLE ITEMS
DRAIN PIPE bore. External use only.

A size(mm) A L Code Col Pk/bx


32/40/50 8 40 4DW200 B 5/60 15.17

Note: As a Terrain Underground product different


discount structure applies.

ADAPTOR TO METAL PIPE Supplied with seal ring.


A size(mm) A B Z Code Col Pk/bx

B 50 70 42 358 226.2 G 5/55 8.75

CAULKING BUSH For connecting MuPVC waste pipe to 50mm socket of


other material. Solvent-weld to pipe.
A
size(mm) A B C D Code Col Pk/bx
32/40/50 43 36 56 70 : 232 G 10/350 3.81
B
C
D

REVERSE NUT ADAPTOR For solvent-weld connection of MuPVC waste pipe (or
Z A
waste fitting) to BSP male threaded fitting or pipe.
size(mm) A L Z Code Col Pk/bx
:
:
32/32 15 50 11 218.125 W 10/300 3.63
40/40 15 53 11 218.15 W 10/250 3.63

200 WASTE TO MALE IRON For solvent-weld connection of MuPVC waste pipe or
Z A
fitting to BSP threaded male pipe or fitting.
Socket and threaded socket.
size(mm) A L Z Code Col Pk/bx
:
:
32/32 23 51 3 212.125 G 10/270 2.84

:
40/40 23 54 3 212.15 G 10/220 2.84
50/50 23 57 3 212.2 G 5/140 4.10

Z A Spigot and threaded socket.


size(mm) A Z Code Col Pk/bx
:
:
32/32 23 3 216.125 G 5/400 2.73

:
40/40 23 3 216.15 G 5/320 3.21
50/50 23 3 216.2 G 5/200 4.59

G - Grey B - Black W - White R - Rustic Brown 23


200-Solvent
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
200 WASTE TO FEMALE IRON For solvent-weld connection of MuPVC waste pipe or AVAILABLE AS SINGLE ITEMS
Z A
fitting to BSP threaded female pipe or fitting.
Socket and threaded socket.
size(mm) A L Z Code Col Pk/bx
:
:
32/32 19 48 3 213.125 G 10/320 2.42

:
40/40 19 51 3 213.15 GW 10/240 2.84
50/50 19 54 3 213.2 GW 5/140 4.10
L

Z A Spigot and threaded socket.


size(mm) A Z Code Col Pk/bx
:
:
32/32 19 6 217.125 G 5/300 2.73

:
40/40 19 6 217.15 G 5/240 3.21
50/50 19 6 217.2 GW 5/160 4.32

Innovative Products
Innovative Products
Universal Soil Manifold New Strap-on Boss
Assembled using mirror Detachable rear strap
welding technology provides back to back
providing a consistent, connection of common or
stronger and more durable different diameters
weld
32mm, 40mm and 50mm
The most compact four boss diameters
entry manifold available
Same diameter of stack
Terrain branded waste opening for all boss sizes
plugs, easily removable for 119P.4.15 112P.4.2
Increased contact area for
installation flexibility
greater installation security
Now available with solvent weld inlets
See page 17 for further details
See pages 10 and 18 for further details

Single Equal Branch Variable Boss New Pipe Marking Template


Unrivalled installation Marking template for access
flexibility branch and boss doors and associated Terrain
pipe incorporated in a single waste bosses
adjustable fitting
With the aid of a spirit level
Direct pipe connection (x2) it is a tool for measuring
for 50mm waste runs no gradients of fall between
additional fitting required 0.5, 1.0 and 2.5 degrees
Joint design assures vertical Can be used to mark angles
alignment during installation 104.412.92 of rotation 0, 15, 45, 90, 9105.500
and operation 135 and 165 degrees
Anti-tamper proof joint means that major product Made from polypropylene, the template is tough,
parts can no longer be separated durable and will not be affected by solvent cement
See page 4 for further details See page 31 for further details

24 G - Grey B - Black W - White R - Rustic Brown


300-PushFit
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
WASTE PIPE Plain-ended. AVAILABLE AS SINGLE ITEMS
size(mm) L T Code Col Pk/bx
(min)

L 32 3m 1.8 1.23 300.125.30 GBW 10 4.12


40 3m 1.9 1.52 300.15.30 GBW 10 5.10
50 3m 2 2.53 300.2.30 G 10 8.50

STRAIGHT COUPLER size(mm) L Z1 Code Col Pk/bx


DOUBLE SOCKET 32 80 2 310.125 GBW 10/350 1.31
40 80 2 310.15 GBW 10/300 1.31
50 70 2 310.2 G 10/200 2.26
L Z1

SWEPT BEND 911/4 and 135 as standard.


DOUBLE SOCKET For 911/4 swept bend
size(mm) angle Z1 Code Col Pk/bx
32 911/4 55 301.125.91 GBW 10/240 1.31
Z1 40 911/4 55 301.15.91 GBW 10/200 1.31
911/4
50 911/4 65 301.2.91 G 10/90 2.26

Z1
For 135 swept bend
size(mm) angle Z1 Code Col Pk/bx
32 135 10 301.125.135 GBW 10/300 1.31
Z1
40 135 11 301.15.135 GBW 10/280 1.31
Z1 50 135 14 301.2.135 G 10/100 2.26

KNUCKLE BEND 90 size(mm) angle Z1 Code Col Pk/bx


DOUBLE SOCKET 32 90 20 302.125.90 GBW 10/160 1.31
40 90 23 302.15.90 GBW 10/220 1.31
50 90 28 302.2.90 G 10/100 2.25
Z1 90

Z1

SWIVEL ELBOW BEND 90 size(mm) angle Z1 Z2 Code Col Pk/bx


SINGLE SOCKET/SPIGOT 32 90 30 60 307.125.90 GW 10/170 1.31
40 90 25 60 307.15.90 GW 10/110 1.31

Z1 90

Z2

SWEPT TEE 911/4 size(mm) angle Z1 Z2 Z3 Code Col Pk/bx


32 911/4 25 30 35 304.125.91 GBW 10/160 1.44
40 911/4 30 33 40 304.15.91 GBW 10/120 1.44
Z1 50 911/4 35 40 46 304.2.91 G 10/70 2.43
911/4
Z3

Z2

* per metre is for estimating purposes only. G - Grey B - Black W - White R - Rustic Brown 25
300-PushFit
Terrain
TerrainWaste Systems
Waste Systems
COLOUR CODES IN BOLD
SOCKET REDUCER To reduce waste socket to accept smaller diameter AVAILABLE AS SINGLE ITEMS
waste pipe.
Z1
size(mm) Z1 Code Col Pk/bx
40/32 35 323.15.125 GBW 10/400 1.41
50/32 35 323.2.125 G 10/180 1.41
50/40 35 323.2.15 G 10/150 2.43

PIPE AND FITTING CLIP size(mm) L1 C1 C2 Code Col Pk/bx


32 70 34 54 340.125 GBW 20/800 0.46
40 77 37 61 340.15 GBW 20/800 0.46

C1

C2

L1

size(mm) L1 C1 C2 Code Col Pk/bx


50 60 51 22 343.2 G 10/600 1.11
C1

C2
L1

ACCESS PLUG size(mm) L1 Z1 Code Col Pk/bx


32 55 17 337.125 GBW 10/500 1.31
L1
40 49 17 337.15 GBW 10/500 1.31
Z1 50 59 10 337.2 G 10/200 2.26

TANK CONNECTOR For connecting push-fit polypropylene pipe to water


tank. Supplied with 2 sealing washers.
size(mm) L1 Z1 Code Col Pk/bx
32 24 7 311.125 GW 10/300 1.31
40 24 7 311.15 GW 10/300 1.31
50 25 7 311.2 G 10/200 2.26
L1
Z1

26 G - Grey B - Black W - White R - Rustic Brown


500-Overflow
Terrain
Terrain Overflow
Overflow
COLOUR CODES IN BOLD
OVERFLOW PIPE Plain-ended. AVAILABLE AS SINGLE ITEMS
size(mm) L T Code Col Pk/bx
(min)

L 19 4m 1.1 1.44 500.75.40 W 20 6.46

STRAIGHT COUPLER size(mm) L Z Code Col Pk/bx


DOUBLE SOCKET 19 40 2 510.75 W 50/1000 1.72
Z

BEND DOUBLE SOCKET 911/4 and 135 as standard.


size(mm) angle Z1 Z2 Code Col Pk/bx

Z2 19 911/4 12 12 501.75.91 W 50/750 2.03


19 135 6 6 501.75.135 W 50/1100 2.04

Z1

BRANCH 911/4 as standard.


size(mm) angle Z1 Z2 Z3 Code Col Pk/bx
Z3 19 911/4 13 13 13 504.75.91 W 10/500 2.21
Z1

Z2

SOCKET REDUCER size(mm) A Z Code Col Pk/bx


centre

A
19/32 5 5 524.75 W 10/1000 2.41

PIPE FIXING CLIP (PLASTIC) size(mm) A Code Col Pk/bx


19 20 540.75 W 50/2500 0.63

* per metre is for estimating purposes only. G - Grey B - Black W - White R - Rustic Brown 27
500-Overflow
Terrain
Terrain Overflow
Overflow
COLOUR CODES IN BOLD
STRAIGHT TANK CONNECTOR To connect cistern/tank to overflow pipe. AVAILABLE AS SINGLE ITEMS
size(mm) A L Code Col Pk/bx
19 48 69 511.75 W 10/250 2.67

A
L

BENT TANK CONNECTOR 90 size(mm) angle A Z1 Z2 Code Col Pk/bx


19 90 48 13 32 502.75.90 W 10/200 3.17
Z1

Z2 A

BSP ADAPTOR To connect PVC-u overflow pipe to threaded


SOLVENT-WELD SOCKET components. Solvent-weld socket to receive overflow
pipe. Threaded socket to receive 3/4" BSP male
AND 3/4" BSP SOCKET
threaded pipe end.
size(mm) A L Code Col Pk/bx
19 14 39 512.75 W 10/750 2.93

A
L

REVERSE NUT CONNECTOR To connect PVC-u overflow pipe to threaded


Z1
components. Threaded loose nut to receive 3/4" BSP
male threaded pipe end.
size(mm) A L Z1 Code Col Pk/bx
19 35 54 25 519.75 W 20/300 0.80
A
L

TUNDISH size(mm) L Code Col Pk/bx


19 117 590.75 W 5/100 42.83
L

28 G - Grey B - Black W - White R - Rustic Brown


600-Traps
Terrain Traps
Terrain Traps
COLOUR CODES IN BOLD
BOTTLE P TRAP 75mm water seal. AVAILABLE AS SINGLE ITEMS
Z2 size(mm) L Z1 Z2 Code Col Pk/bx
:
:
32 166 47 62 611.125 W 5/60 8.15
Z1
40 170 50 59 611.15 W 5/60 9.72
L

BOTTLE P TRAP Supplied with insert to create an air by-pass to protect


SELF RE-SEALING water seal.
75mm water seal.
Z2
size(mm) L Z1 Z2 Code Col Pk/bx
:
:
Z1
32 166 47 62 615.125 W 5/60 10.14
L 40 170 50 59 615.15 W 5/50 11.85

TUBULAR P TRAP Mid-point release nut to allow adjustment.


Z2 Z3
75mm water seal.
size(mm) L Z1 Z2 Z3 Code Col Pk/bx
:
Z1

:
32 136 11 66 29 631.125 W 5/80 7.32
L
40 148 11 72 31 631.15 W 5/65 8.45

TUBULAR S TRAP Mid-point release nut to allow adjustment.


75mm water seal.
size(mm) C C L Z1 Z2 Z3 Code Col Pk/bx

:
(max) (min)
L

:
Z1 32 132 48 136 95 66 66 632.125 W 5/60 9.27
40 144 55 148 107 72 72 632.15 W 5/50 10.84
Z2 Z3
C

TUBULAR RUNNING P TRAP Universal compression inlet and outlet to suit copper
Z3 Z2 Z1 and plastic pipes.
75mm water seal.
size(mm) L Z1 Z2 Z3 Code Col Pk/bx
:
:
L 32 135 28 66 28 645.125 W 5/60 11.21
40 145 31 72 31 645.15 W 5/45 12.30

SPIGOT/SOCKET BEND To convert tubular or bottle P traps to S traps.


size(mm) Z1 Z2 Code Col Pk/bx
:
Z2

:
32 27 61 607.125.90 W 5/135 2.89
40 31 65 607.15.90 W 5/110 3.07
Z1

WASHING MACHINE TRAP Ramped entry for washing machine connection to


Z2 prevent splash back through waste outlet. Multi-joint
Z4
Z3
connection for washing machine e.g. plain hose or
Z5 Z1 reverse nut thread for 19mm and 25mm connection.
size(mm) L Z1 Z2 Z3 Z4 Z5 Code Col Pk/bx
:
L

40 177 37 72 31 132 28 633.15 W 5/40 14.65

G - Grey B - Black W - White R - Rustic Brown 29


600-Traps
Terrain Traps
Terrain Traps
COLOUR CODES IN BOLD
WASHING MACHINE To accept flexible waste pipes from domestic washing AVAILABLE AS SINGLE ITEMS
STANDPIPE machines and dishwashers. Providing necessary air
break to prevent continuous syphoning.
size(mm) A L BSP Code Col Pk/bx
thread
L 40 19 501 40 : 9250 W 5/75 11.10

TUBULAR P BATH TRAPS Supplied with flexible overflow hose.


75mm water seal.
Z2 Z3 Install with 690, 691, 692 or 693 overflow outlets.
Z1
size(mm) L Z1 Z2 Z3 Code Col Pk/bx

L
40 143 2 72 31 : 651.15 W 5/30 15.66

TUBULAR LOWLINE P Supplied with blanking plug-cleaning eye.


BATH TRAPS 50mm water seal.
size(mm) A L Z1 Z2 Z3 Code Col Pk/bx
:
A
Z2 Z3
40 172 93 32 141 31 657.15 W 5/50 10.15

Z1

TUBULAR LOWLINE P 50mm water seal.


BATH TRAP WITH OVERFLOW Install with 690 or 691 overflow outlets.
size(mm) A B L Z1 Z2 Z3 Code Col Pk/bx
A
Z3
40 172 77 93 32 141 31 : 659.15 W 5/25 15.72
Z2
Z1

L Z1

BATH OVERFLOW OUTLET Spigot outlet accepts flexible overflow tube.


B Supplied with plug and chain.
Plastic
A B Code Col Pk/bx
:
A
42 57 690.075 W 5/100 9.78
Chrome-plated
A B Code Col Pk/bx
42 57 691.075 W* 5/100 10.96

30 G - Grey B - Black W - White R - Rustic Brown


Accessories
Accessories/Ancillaries
Accessories/Ancillaries
COLOUR CODES IN BOLD
INTUMESCENT PIPE COLLAR An intumescent sleeve is designed to prevent the AVAILABLE AS SINGLE ITEMS
spread of fire and smoke where PVC-u pipes penetrate
a fire rated compartment wall or floor.
size(mm) weight(g) fire Code Col Pk/bx
rating
50 472 2 hrs 1725.2 S/Steel 5/50 41.24
82 778 2 hrs 1725.3 S/Steel 5/50 49.36
110 1016 2 hrs 1725.4 S/Steel 5/25 55.60
160 2534 2 hrs 1725.6 S/Steel 5/10 106.25

FIXING BOLTS Heavy duty expanding fixing bolts pack of 4.


Code Col Bx
1726 1/100 2.32

TOGGLE BOLT To clamp 112 and 115 Boss Connectors while solvent-
welding.
Code Col Pk/bx
9115 Self 1/50 26.60

PACKING PIECE For use with 140 and 142 Pipe Brackets and 191
Intermediate Support Brackets.
size(mm) Code Col Pk/bx
82 9104.3 G 1 3.25
110 9104.4 GB 10/200 3.01
160 9104.6 G 1/100 5.85

PIPE MARKING TEMPLATE Marking guide for Terrain Soil Systems, access and boss
connection
size(mm) Code Col Pk/bx
110 9105.500 Blue 1/ 12.04

G - Grey B - Black W - White R - Rustic Brown 31


Accessories
Accessories/Ancillaries
Accessories/Ancillaries
COLOUR CODES IN BOLD
WC PAN SEAL (SOIL) Material: EPDM AVAILABLE AS SINGLE ITEMS
Replacement seal for pan outlet diameter 951/4121mm.
size(mm) Code Col Pk/bx
110 9124 B 1/100 8.05

SPARE SEAL RINGS (SOIL) Material: EPDM


Suitable for:
soil system expansion sockets and soil pipe
use with 126 Adaptors to Cast Iron
soil fittings (as listed).
size(mm) For fittings Code Col Pk/bx
110 Push Fit Soil (P) range 9116.4 B 1 1.66
160 Push Fit Soil (P) range 9116.6 B 1 3.14
82 109/111/111.S/126/132 9120 B 1 2.43
110 103/105/109/111/111.S/126/132/137 9119.B B 1 2.77
Material: EPDM
Allows soil fittings to accept metric copper pipe to BS
2871.
size(mm) Code Col Pk/bx
110 9149 Red 1 5.98

SPARE SEAL RING (WASTE) Suitable for:


200 Waste System Fittings to accept pipe
manufactured to BS 5255 and BS 5254.
Acceptable for:
copper pipe to BS 659 and BS 2781.
size(mm) Code Col Pk/bx
32 9132.125 B 1 0.47
40 9132.15 B 1 0.52
50 9132.2 B 1 0.69

SEALING INSERT (SPARE) Material: EPDM.


size(mm) Code Col Pk/bx
40 9113 B 1 0.96

MANIFOLD PLUG (SPARE) Material: Polypropylene.


size(mm) Code Col Pk/bx
40 9114 G 1 1.08

CLEANING FLUID Material: Acetone.


For cleaning PVC-u pipe and fittings before applying
Liquid Weld.
Screw top cans.
size(ml) Code Col Pk/bx
125 9101.125 12/24 6.48
250 9101.250 12/24 8.30

LUBRICANT Material: Silicone grease Soluble lubricant.


For lubricating seal rings on expansion fittings.
size(ml) Code Col Pk/bx
50 Tube (silicone) 9136.50 10/150 10.12
250 Tub (silicone) 9136.250 10/40 34.91
500 Tub (soluble) 9136.500 10/20 6.14

LIQUID WELD For solvent jointing of PVC-u pipes and fittings cap
incorporates integral brush.
size(ml) Code Col Pk/bx
125 9100.125 12/24 8.83
250 9100.250 12/24 12.13
500 9100.500 12 22.42

32 G - Grey B - Black W - White R - Rustic Brown


Design
DesignConsiderations
Considerations
Building Regulations Check subsequently to ensure that Access
the expansion gap is not lost during
Requirements further installation work. Sufficient and suitable access must
All sanitary pipework and drainage be provided to enable all pipework
installations must satisfy the relevant to be tested and maintained
requirements of Part H1 of the Branch connections effectively. Access covers, plugs or
approved documents to the caps should be installed in positions
The distance between the centreline
England, Wales and Northern to facilitate use of testing
of the lowest branch connection to
Ireland Building Regulations 1990 equipment and removal of
the discharge stack and the invert of
and the Building Standards blockages.
the bend at the foot of the stack
(Scotland) amendment regulations should be in accordance with the
1982.
Fire Spread
following:
In large commercial or housing
Installations in accordance with BS
developments, compartmentation
EN 12056:2 3 storeys 450mm min. may be required by the Building
Code of practice for sanitary
5 storeys 750mm min. Regulations 1991 (Part B 3(2)
pipework will also meet Building
Schedule 1). In such cases, any
Regulations requirements. 5 storeys + Ground floor penetrations by sanitary pipework
Ventilation connections must be suitably fire stopped.
The discharge stack must be should discharge Suitable measures include the
ventilated in order to prevent direct to drain or containment of pipes from floor to
pressure building up within the into their own ceiling in a fire resistant enclosure
system and drawing the water seals stack (with appropriate fire rating).
in the traps.
20 storeys + Ground and In addition, the Terrain Firebrake
Separate ventilation of branch pipes
first floor Intumescent Sleeve has been
is required only if the length and
connections designed to meet the highest fire
slope of the branch exceeds the
should discharge stopping requirements.
following dimensions:
into their own Pipe support
Maximum length:
stack
(32mm) 1.7 metres Pipes must be adequately supported
(40mm) 3 metres when installed vertically or
(50mm) 4 metres A branch pipe should not discharge horizontally (to falls).
Slope: 18-90mm per metre into a stack in a way which could
cause crossflow into any other
In such cases, the branch pipe
branch pipe.
should be ventilated by a branch
ventilating pipe or an anti-syphon Working temperatures
trap should be fitted.
Terrain Soil and Waste systems may
The Automatic Air Admittance Valve be used to convey liquids with a
reduces the number of stack maximum temperature of 76C
ventilating pipes required to when subjected to continuous flow.
penetrate the roof in multi- Intermittent discharges of up to
installations, without affecting 100C may occur provided they are
performance of the drainage of less than 2 minutes duration.
system.
Thermal expansion
Chemical discharges
Within a solvent-weld system it is Terrain Soil and Waste systems are
important to make adequate generally resistant to most
allowance for thermal movement. commonly used acids and those
This is most easily achieved by that may be discharged to the
fitting an expansion ring seal joint public sewer system. The rubber
between two fixed solvent-weld seals, however, are less resistant and
joints. it is advised that before any
chemicals are conveyed through the
The expansion gap should be
systems, checks are made to
created by pushing the spigot fully
establish their effects on the
into the ring seal socket, and
product. Refer to BS CP 312 Part 1
marking the position at the socket
Code of Practice for Plastic Pipework
face. Then withdraw the spigot by
for further information.
10mm.

33
Fabrication Service
Fabrication Service
Fabricated specials Custom specials
These are designed and
Our Fabrication Service is able to
fabricated specifically to
help you by producing Specials
meet the unique design
to overcome those tricky
requirements created by
problems that arise in the design Raked angle gutter outlet with built-
special architectural features.
process and on site. in overshoot guard.
They can be made not only
on a one-off or small batch
basis, but also in their
hundreds, subject to the
demands of your particular
project.
They can be produced to
your precise specification in
virtually any size or shape.
Our experienced fabricators are able Double branches can be made to any
to satisfy the requirements of any Custom Specials provide size and angle.
project. solutions to otherwise
unsolvable design problems. These offer a number of
Standard specials Delivery time depends upon benefits:
These are produced by the complexity of the design Time and labour costs on
making slight modifications and number required. site are reduced by mini-
to existing Terrain products mising the joints to be
Examples of situations in
to suit frequently occurring made.
which Custom Specials have
design problems e.g. special provided solutions include a Highly efficient for
gutter angles for bay PVC drain outlet filter commercial, leisure and
windows, conservatories etc. designed to catch tiny pieces housing projects where
These products tend to be of gold fillings positioned identical plumbing
required regularly, but in beneath the operating area arrangements are repeated a
small quantities. in a dental surgery; and number of times.
specially designed silt traps
Delivery lead time is usually Can be quickly installed,
to deal with drainage needs
the same as for standard reducing the need to re-
at football grounds.
catalogue items. locate residents, making
them ideal for refurbishment
Standard Specials have an F work.
prefix added to the standard Pre-fabricated stacks
number and can be found in Taking a typical house as an
our price list. With increased labour shortages,
example, stacks are pre-welded
the more aspects of the
and supplied in four sections:
construction process that can be
dealt with in the factory rather Drain socket to kitchen
than on-site, the greater the connection.
benefits for everyone. Intermediate section
including bathroom
Solving problems at the design connection.
and manufacturing stage
ensures right first time quality, Top section through roof.
increased predictability of Connection to W.C.
construction time and cost, and
Multi entry branch designed to suit
customers unique requirements.
improvements to both site They are available in four
productivity and health and colours: grey, white, black and
safety. rustic brown. Delivery time is
dependent on quantities
Prefab Stacks consist of soil and required.
waste pipes and fittings pre-
assembled at the factory to pre- You provide us with architect
determined lengths to provide a drawings and, ideally the
Gutter offset unit bespoke to fit modular soil and vent stack. sanitaryware schedule, and we
individual building dimensions. do the rest.
34
Fabrication Service
Fabrication Service
Specials
There are occasions on which
even the most comprehensive
standard product system wont
meet up to the demands of a
particularly complex design or
installation.

And at times like this, the Terrain


Fabrication Service is uniquely
placed to help you.

TERRAIN FABRICATION Pre-fabrication


SERVICE
Shortage of skilled labour is just
Specialists in one reason for the growth of 2. We will then advise you on
pre-fabrication within design possibilities and send
fabrication
construction. Moving significant you back CAD diagrams, if
elements of the process from site necessary, complete with a
The Terrain Fabrication team
to factory provides improvements part number and price for
works closely with our Technical
in quality, cost and time your approval.
Services Department, employing
predictability, productivity and
the latest design and If the special is being
safety.
manufacturing technologies. incorporated into the design
With unrivalled expertise in PVC stage of a drainage layout,
Together, they produce high be sure to include the
and HDPE fabrication systems,
quality Pre-fabricated Stacks and unique part number with
our Fabrication Service has been
Specials, either by making any plans to be passed to
helping specifiers and
modifications to existing the contractor.
contractors overcome problems,
products from the Terrain range,
both at the design stage and on 3. You place the order through
or by conceiving components
site, for over 30 years. your local merchant, stating
from scratch to deal with
particularly awkward problems. the unique product number
Three easy steps for and price.
Where fittings are designed our Special Fabrication
specially, CAD technology is used Whether at the design stage or
to provide accurate drawings,
Service on site, should you come up
along with indications of all against a problem related to
It couldnt be simpler to order plumbing and drainage, look no
relevant dimensions.
Specials or have a Pre-fabricated further than the Terrain Special
Stack manufactured for you. Fabrication Service.
Our fabrication team provides
services in two key areas. 1. Send a dimensioned sketch
and specification by email,
fax or post to our Technical
Services Department.

35
Design Data
Design Data
Table A: Discharge units (DU) Values
Example
Appliance System III DU l/s NB Under no
Wash basin, bidet 0.3 10 storey building with circumstances

]
Shower without plug 0.4 4 WC
should pipe of
a larger
Shower with plug 1.3 2 WHB
diameter be
2 Baths
Single urinal with cistern 0.4 On each floor connected to
2 Showers pipe of a
Urinal with flushing valve
2 Sinks smaller
Slab urinal 0.2*
2 W/MC diameter in
Bath 1.3 the direction
4 x 1.5 = 6.0
Kitchen sink 1.3 of flow.
2 x 0.3 = 0.6
Dishwasher (household) 0.2
2 x 1.3 = 2.6
Washing machine up to 6 kg 0.6 2 x 0.4 = 0.8
Washing machine up to 12 kg 1.2 2 x 1.3 = 2.6
WC with 4.0 L cistern ** 2 x 0.6 = 1.2

WC with 6.0 L cistern 1.2 to 1.7*** 13.8 x 10 = 138 DU

WC with 7.5 L cistern 1.4 to 1.8*** Domestic Building Use K = 0.5

WC with 9.0 L cistern 1.6 to 2.0*** 0.5 138 = 5.87 l/s


Floor gully DN 50
See Table C and D for capacities
Floor gully DN 70 of pipes.

Floor gully DN 100

* Per person.
** Not permitted.
*** Depending upon type (valid for WCs with siphon flush cistern only).
Not used or no data.

Table B: Typical frequency factors (K)


Frequency factor (K)
Usage of appliances K
Typical frequency factors associated
Intermittent use, e.g. in with different usage of appliances
0.5 Table B.
dwelling, guesthouse, office
Calculation of flowrate
Frequent use, e.g. in hospital,
0.7 Waste water flowrate (Qww)
school, restaurant, hotel
Qww is the expected flowrate of
Congested use, e.g. in toilets waste water in a part or in the whole
1.0 drainage system where only domestic
and/or showers open to public sanitary appliances are connected to
the system
Special use, e.g. laboratory 1.2 Qww = KDU
where:
Qww = Waste water
flowrate (l/s)
K = Frequency factor
DU = Sum of discharge
units.

36
Design Data
Design Data
Table C: Stack with only Primary Vent Table D: Stack with Secondary Venting
Stack and System I, II, III, IV Stack and Secondary System I, II, III, IV
stack vent Qmax (L/s) stack vent vent Qmax (L/s)
DN Square #entries Swept entries DN DN Square #entries Swept entries
60 0.5 0.7 60 50 0.7 0.9
70 1.5 2.0 70 50 2.0 2.6
80* 2.0 2.6 80* 50 2.6 3.4
90 2.7 3.5 90 50 3.5 4.6
100** 4.0 5.2 100** 50 5.6 7.3
125 5.8 7.6 125 70 7.6 10.0
150 9.5 12.4 150 80 12.4 18.3
200 16.0 21.0 200 100 21.0 27.3
* Minimum size where WCs are connected in system II. * Minimum size where WCs are connected in system II.
** Minimum size where WCs are connected in system I, III, ** Minimum size where WCs are connected in system I,
IV. III, IV.

#Equal branch junctions that are more than 45, or has a centre line radius less than the internal pipe diameter.
For branch pipe sizing based on System III the following sizing charts should be used.

Limitations for unventilated branch discharge pipes, system III Limitations for ventilated branch discharge pipes, system III
Appliance Diameter Min. trap Max length Pipe Max. Max. Appliance Diameter Min. trap Max length Pipe Max. Max.
seal (L) of pipe gradient number of drop seal (L) of pipe gradient number of drop
depth from trap bends (H) depth from trap bends (H)
outlet to outlet to
stack stack
DN mm m m DN mm m m
Washbasin, bidet 30 75 1.7 2.21) 0 0 Washbasin, bidet 30 75 3.0 1.8 Min. 2 3.0
(30mm diameter trap) (30mm diameter trap)
Washbasin, bidet 30 75 1.1 4.41) 0 0 Washbasin, bidet 40 75 3.0 1.8 Min. No Limit 3.0
(30mm diameter trap) (30mm diameter trap)
Washbasin, bidet 30 75 0.7 8.71) 0 0 Shower, bath 40 50 No Limit2) 1.8 Min. No Limit No Limit
(30mm diameter trap)
Bowl urinal 40 75 3.03) 1.8 Min. No Limit4) 3.0
Washbasin, bidet 40 75 3.0 1.8 to 4.4 2 0
(30mm diameter trap) Trough urinal 50 75 3.03) 1.8 Min. No Limit4) 3.0
Shower, bath 40 50 No Limit2) 1.8 to 9.0 No Limit 1.5 Slab urinal3) 60 50 3.03) 1.8 Min. No Limit4) 3.0
Bowl urinal 40 75 3.03) 1.8 to 9.0 No Limit4) 1.5 Kitchen sink 40 75 No Limit2) 1.8 Min. No Limit No Limit
(40mm diameter trap)
Trough urinal 50 75 3.03) 1.8 to 9.0 No Limit4) 1.5
Household dishwasher or 40 75 No Limit3) 1.8 Min. No Limit No Limit
Slab urinal3) 60 50 3.03) 1.8 to 9.0 No Limit4) 1.5 washing machine
Kitchen sink 40 75 No Limit2) 1.8 to 9.0 No Limit 1.5 WC with outlet up to 75 50 No Limit 1.8 Min. No Limit4) 1.5
(40mm diameter trap) 80mm6) & 14)
Household dishwasher or 40 75 3.0 1.8 to 4.4 No Limit 1.5 WC with outlet greater 100 50 No Limit 1.8 Min. No Limit4) 1.5
washing machine than 80mm6) & 14)
WC with outlet up to 75 50 No Limit 1.8 Min. No Limit4) 1.5 Food waste disposal7) 40 Min. 758) 3.03) 13.5 Min. No Limit4) 3.0
80mm6)
Sanitary towel 40 Min. 758) 3.03) 5.4 Min. No Limit4) 3.0
WC with outlet greater 100 50 No Limit 1.8 Min. No Limit4) 1.5 disposal unit
than 80mm6)
Bath drain, Floor drain 50 50 No Limit3) 1.8 Min. No Limit No Limit
Food waste disposal7) 40 Min. 758) 3.03) 13.5 Min. No Limit4) 1.5
Floor drain 70 50 No Limit3) 1.8 Min. No Limit No Limit
Sanitary towel 40 Min. 758) 3.03) 5.4 Min. No Limit4) 1.5
disposal unit Floor drain 100 50 No Limit3) 1.8 Min. No Limit No Limit
Floor drain 50 50 No Limit3) 1.8 Min. No Limit 1.5 5 basins9) 50 75 7.0 1.8 to 4.4 2) 0
Floor drain 70 50 No Limit3) 1.8 Min. No Limit 1.5 10 basins9) & 10) 50 75 10.0 1.8 to 4.4 No Limit 0
Floor drain 100 50 No Limit3) 1.8 Min. No Limit 1.5 Bowl urinals9) & 11) 50 70 No Limit3) 1.8 Min. No Limit4) No Limit
4 basins 50 75 4.0 1.8 to 4.4 0 0 More than 8 WCs6) 100 50 No Limit 0.9 Min. No Limit No Limit
Bowl urinals3) 50 75 No Limit3) 1.8 to 1.9 No Limit4) 1.5 Up to 5 spray tap 30 Max. 50 No Limit3) 1.8 to 4.4 No Limit4) 0
basins12)
Maximum of 8 WCs6) 100 50 15.0 0.9 to 9.0 2 1.5
Up to 5 spray tap 30 Max. 50 4.53) 1.8 to 4.4 No Limit4) 0 1) For maximum distances from trap to vent (see Figure 8 of BS EN 1205-2:2000).
basins9) 2) If length is greater than 3m noisy discharge may result with an increased risk of blockage.
3) Should be as short as possible to limit problems with deposition.
1) Steeper gradient permitted if pipe is less than maximum permitted length. 4) Sharp throated bends should be avoided.
2) If length is greater than 3m noisy discharge may result with an increased risk of blockage. 5) For slab urinal for up to 7 persons. Longer slabs to have more than one outlet.
3) Should be as short as possible to limit problems with deposition. 6) Swept-entry branches serving WCs.
4) Sharp throated bends should be avoided. 7) Includes small potato-peeling machines.
5) For slab urinal for up to 7 persons. Longer slabs to have more than one outlet. 8) Tubular not bottle or resealing traps.
6) Swept-entry branches serving WCs. 9) See Figure 9 of BS EN 12056-2:2000).
7) Includes small potato-peeling machines. 10) Every basin shall be individually ventilated.
8) Tubular not bottle or resealing traps. 11) Any number.
9) Spray tap basins shall have flush-grated wastes without plugs. 12) Spray tap basins shall have flush-grated wastes without plugs.
13) The size of ventilating pipes to branches from appliances can be DN 25 but, if they are
longer than 15m or contain more than five bends, a DN 30 pipe shall be used.
14) If the connection of the ventilating pipe is liable to blockage due to repeated splashing or
Ventilated discharge branches submergence, it should be DN 50, up to 50mm above the spill-over of the appliance.
Sizes and limitations upon the use of ventilated discharge branches are
given in the tables above. Limitations given in the second table are
simplifications, for further information see national and local regulations
and practice.
37
Socket
Socket Dimensions
Dimensions
100 SOIL SYSTEM PVC-u (SOLVENT-WELDED) *

82, 110 and 160mm pipe and fittings (Fig. 1) Solvent-


AB
welded
A B C T1 T2
(min) (min)

82 95 51 3.2 3.2
T1 T2
110 122 51 3.2 3.2 Fig. 1 C
160 175 76 3.3 3.5

100P SOIL SYSTEM PVC-u (PUSH-FIT) *


D

82, 110 and 160mm pipe and fittings (Fig. 2)


A
A(Fig. 2) D E T2 E
Push-fit
82 100 50 3.2
110 132 58 3.4
160 189 70 4.1 T1 T T2
Fig. 2

200 WASTE SYSTEM MuPVC (SOLVENT-WELDED)


32, 40 and 50mm pipe and fittings (Fig. 3) A B

Nom. A B C D E T1 T2
(min) (min)

32mm 36 42 24 53 44 1.8 1.8 T2 T2


40mm 43 49 27 60 44 1.9 1.9 C
Fig. 3 Solvent-weld jointing
50mm 56 62 30 75 44 2.0 2.0

300 WASTE SYSTEM POLYPROPYLENE (PUSH-FIT)


32, 40 and 50mm pipe and fittings (Fig. 4) A D

Nom. A D E T2 T1
32mm 35 41 20 1.8
40mm 41 47 23 1.9
50mm 54 61 29 2.0 T1 T2
E
Fig. 4 Seal ring jointing

500 OVERFLOW SYSTEM


For cold, non-pressure water. Sockets are for solvent-weld jointing
A
19mm pipe and fittings (Fig. 5)
A B T1 T2
(min) (min)
T1 T2
Fig. 5 B
21 19 1.1 2.0

600 TRAPS SYSTEM


32, 40 and 50mm sockets (Fig. 6)
B C maximum
size A B
(min)

32mm 55 42
40mm 65 49

Tubular S traps limits (Fig. 7) A


C maximum C minimum
(trap folded) C minimum
(trap
folded)
Part no. C C
(max) (min)
Fig. 6 Fig. 7
632.125 136 50
632.15 150 60 All dimensions in mm unless otherwise stated.
38
Numerical Index
Numerical Index
Code Colour Page Code Colour Page Code Colour Page

111.S.3 G 19.11 2 140.4 Self 4.99 7


100-Solvent 111.S.4 GB 23.93 2 140.6 Self 12.01 7
111.S.6 G 61.27 2 142.4 Self 10.37 7
100.3.30 GBW 34.78 2 112.3.15 G 8.44 9 143.3 GBW 3.57 7
100.3.40 GBW 46.38 2 112.4.125 G 8.44 9 143.4 GBWR 3.34 7
100.4.30 GBWR 35.45 2 112.4.15 G 8.44 9 144.4 BW 6.78 7
100.4.40 GBWR 47.24 2 112.4.2 GW 8.76 9 149.16.00 Alu/B 51.74 8
100.6.30 G 91.87 2 112.6.2 G 11.95 9 149.18.22 Alu/B 53.05 8
100.6.40 G 122.49 2 115P.4 GWR 6.94 12 149.24.22 Alu/B 71.69 8
101.3.92 GBW 15.44 2 117.125 GBW 3.36 11/17 150.3 GB 4.35 8
101.3.135 GBW 15.44 2 117.15 GBWR 3.36 11/17 150.4 GBWR 4.40 8
101.4.025 G 33.79 3 117.15.90 GBW 5.01 11 150.6 G 11.51 8
101.4.92 GBWR 18.07 2 117.2 GBW 4.79 11/17 152.4 GBR 19.71 8
101.4.104 G 18.07 2 117.2.90 GBW 6.01 11 153.3.4 W 52.67 8
101.4.112 GB 18.07 2 117.2.150 G 5.24 11 153.3.4I Self 1.88 8
101.4.135 GBWR 18.07 2 119.412.15 G 32.29 10 190.3 Self 29.76 7
101.6.92 G 45.00 2 120.3.2 GB 12.97 10 190.4 Self 32.38 7
101.6.135 G 45.00 2 120.4.125 GBWR 6.46 9 190.6 Self 51.33 7
102.4.5 W 28.04 13 120.4.15 GBWR 6.46 9 191.3 Self 15.15 7
103.4.92 GBW 50.12 6 120.4.2 GB 10.48 10 191.4 Self 16.47 7
104.3.92 GBW 21.57 3 120.412.15 GR 6.27 9 191.6 Self 22.04 7
104.3.135 GB 21.57 3 120.412.2 G 10.48 10 4DW3* B 15.17 11
104.4.92 GBWR 23.90 3 121.4.15 GB 10.48 10 6592/DVW GBWR POA 16
104.4.924 GBW 29.00 3 122.4.125 GW 11.28 9
104.4.104 G 29.00 3 122.4.15 GB 11.78 9 100P-PushFit
104.4.135 GBW 24.93 3 122.4.2 GBW 15.22 9
104.6.92 G 50.74 3 123.4 GBW 6.81 9
100P.3.30 G 30.67 14
104.6.135 G 96.84 3 124.3.2 GW 9.35 10
100P.3.40 G 40.80 14
104.104.92 GB 31.14 4 124.4.2 GBW 11.66 10
100P.4.30 GBW 30.91 14
104.412.92 G 53.96 4 124.4.3 GBW 12.01 10
100P.4.40 GBW 41.22 14
104.422.92 G 53.96 4 124.6.4 GW 24.35 10
100P.6.30 G 83.03 14
104.64.92 G 57.29 4 125.4.5 W 17.08 13
100P.6.40 G 110.75 14
104.64.135 G 61.57 4 126.3.12 G 10.92 11
101P.3.92 G 14.96 14
105.4.92 GB 40.92 6 126.4.12 G 14.66 11
101P.4.92 GBW 16.11 14
106.104.92 G 59.07 5 128.4.02 W 10.92 13
101P.4.112 G 18.01 14
106.4.92 GBW 59.07 5 128.4.025 W 34.83 13
101P.4B.112 GBW 21.14 15
106.4.135 G 61.74 5 128.4.90 W 17.55 13
101P.4T.112 GB 21.14 15
106.64.92 G 106.71 5 129.4.05 W 23.46 12
101P.6.92 G 48.36 14
106.490.12 G 118.68 5 129.4.104 W 14.49 12
103P.4.92 GB 44.36 16
106.490.22 G 118.68 5 129.4.14 W 23.46 12
104P.3.92 G 23.50 15
106.490.92 G 104.32 4 129.4.24 W 23.46 12
104P.4.92 GBW 21.73 15
107.3.92 G 14.94 3 129.4.34 W 23.46 12
104P.4.112 G 30.71 15
107.35.05 B 21.72 12 129.4.90 W 19.89 12
104P.4.135 G 22.37 15
107.35.14 B 21.72 12 130.4 GBW 10.61 9/18
104P.6.92 G 56.03 15
107.35.24 B 21.72 12 130.6 G 19.49 9/18
105P.4.92 G 50.99 16
107.35.34 B 21.72 12 131.3 GB 4.35 8
106P.4.92 GB 56.89 15
F107.35.09 B 21.72 12 131.3.200 G 18.36 8
107P.3.135 G 13.17 14
F107.35.18 B 21.72 12 131.4 GBWR 4.99 8
107P.4.92 G 16.27 14
F107.35.29 B 21.72 12 131.4.200 GR 18.36 8
107P.4.135 GBW 16.26 14
107.4.025 G 33.93 3 131.6 G 15.02 8
107P.6.135 G 46.65 14
107.4.92 GBW 17.51 3 132.4 G 14.44 12
110P.3 G 11.81 14
107.4.135 GBW 19.65 3 135.3 G 20.55 6
110P.4 GBW 10.73 14
107.6.135 G 43.52 3 135.4 GB 20.55 6
110P.6 G 25.36 14
109.3 GB 3.91 2 135.6 G 36.72 6
111P.3 G 6.69 14
109.4 GBWR 3.82 2 136.3 GW 14.55 6
111P.4 GBW 7.51 14
109.6 G 10.29 2 136.4 GBWR 17.15 6
111.SP4 G 13.07 14
110.3 GBW 6.15 2 136.6 G 32.28 6
112P.4.125 BW 7.17 17
110.4 GBWR 7.69 2 137.3 GBW 37.79 6
112P.4.15 GBW 7.17 17
110.6 G 22.17 2 137.4 GBW 38.39 6
112P.4.2 GB 7.24 17
111.3 GBW 9.20 2 138.4 GBWR 25.35 5
115P.4 G 6.94 17
111.4 GBW 9.40 2 139.4 GB 25.35 5
119P.4.15 G 32.74 18
111.6 G 28.31 2 140.3 Self 4.80 7
120P.412.2 G 11.34 18

G - Grey B - Black W - White R - Rustic Brown 39


Numerical Index
Numerical Index
Code Colour Page Code Colour Page Code Colour Page

120P.4.15 GB 8.80 18 212.15 G 2.84 23 302.125.90 GBW 1.31 25


123P.3 G 8.71 17 212.2 G 4.10 23 302.15.90 GBW 1.31 25
123P.4 GB 8.80 17 213.125 G 2.42 24 302.2.90 G 2.25 25
124P.3.2 G 11.03 17 213.15 GW 2.84 24 304.125.91 GBW 1.44 25
124P.4.2 GB 15.36 17 213.2 GW 4.10 24 304.15.91 GBW 1.44 25
124P.4.3 G 15.36 17 216.125 G 2.73 23 304.2.91 G 2.43 25
124P.6.4 G 22.14 17 216.15 G 3.21 23 307.125.90 GW 1.31 25
129P.4.00 W 13.16 18 216.2 G 4.59 23 307.15.90 GW 1.31 25
129P.4.90 W 13.15 18 217.125 G 2.73 24 310.125 GBW 1.31 25
136P.3 G 11.99 16 217.15 G 3.21 24 310.15 GBW 1.31 25
136P.4 GBW 14.14 16 217.2 GW 4.32 24 310.2 G 2.26 25
136P.6 G 33.23 16 218.125 W 3.63 23 311.125 GW 1.31 26
139P.3 G 29.44 16 218.15 W 3.63 23 311.15 GW 1.31 26
139P.4 GB 29.39 16 223.15.125 G 1.99 21 311.2 G 2.26 26
139P.6 G 61.70 16 223.2.125 GW 2.47 21 323.15.125 GBW 1.41 26
6592/DVW GBWR POA 16 223.2.15 G 2.46 21 323.2.125 G 1.41 26
224.15.125 GBWR 1.60 21 323.2.15 G 2.43 26
200-Solvent 224.2.125 GBW 2.31 21 337.125 GBW 1.31 26
224.2.15 GBW 2.82 21 337.15 GBW 1.31 26
225.125 GW 2.81 19 337.2 G 2.26 26
200.125.30 GW 7.68 19
225.15 GW 3.39 19 340.125 GBW 0.46 26
200.125.40 GBWR 10.23 19
225.2 GW 4.59 19 340.15 GBW 0.46 26
200.15.30 GW 9.50 19
226.2 G 8.75 23 343.2 G 1.11 26
200.15.40 GBWR 12.66 19
227.125 GW 2.81 19
200.2.30 W 14.31 19
227.15 GW 3.39 19 500-Overflow
200.2.40 GBW 19.09 19
227.2 G 4.59 19
201.125.91 GBWR 1.62 20
231.2 G 3.38 21
201.125.135 GBWR 1.62 20 500.75.40 W 6.46 27
232 G 3.81 23
201.125.165 G 2.46 20 501.75.91 W 2.03 27
237.125 GBW 1.48 21
201.15.91 GBWR 1.81 20 501.75.135 W 2.04 27
237.15 GBW 1.48 21
201.15.135 GBWR 1.81 20 502.75.90 W 3.17 28
237.2 GBW 2.13 21
201.15.165 G 3.19 20 504.75.91 W 2.21 27
240.125 GBWR 0.52 21
201.2.91 GBW 3.18 20 510.75 W 1.72 27
240.15 GBWR 0.60 21
201.2.135 GBW 3.18 20 511.75 W 2.67 28
240.2 GBW 0.80 21
201.2.165 G 4.20 20 512.75 W 2.93 28
242.125 GW 0.63 21
202.125.91 GBWR 1.48 20 519.75 W 0.80 28
242.15 W 0.71 21
202.15.91 GBWR 1.63 20 524.75 W 2.41 27
242.2 GW 1.53 21
204.125.91 GBWR 2.18 20 540.75 W 0.63 27
243.125 Self 2.29 21
204.125.135 GW 2.61 20 590.75 W 42.83 28
243.15 Self 2.73 21
204.15.91 GBWR 2.76 20
243.2 Self 3.47 21
204.15.135 GW 3.45 20 600-Traps
250.2 GW 3.84 22
204.2.91 GBW 5.39 20
253W W 20.36 22
204.2.135 GBW 5.39 20
281.43 GT 21.22 22 607.125.90 W 2.89 29
206.15.91 GW 6.71 20
281.64 GT 21.22 22 607.15.90 W 3.07 29
206.2.91 GW 7.03 20
282.6 GW 7.70 22 611.125 W 8.15 29
206.2.135 G 45.98 20
283.6 Self 15.58 22 611.15 W 9.72 29
207.125.92 GBW 2.66 20
284.6 GW 9.43 22 615.125 W 10.14 29
207.125.135 GBW 2.64 20
285.6 Self 15.94 22 615.15 W 11.85 29
207.125.150 GB 2.75 20
4DW200* B 15.17 23 631.125 W 7.32 29
207.15.92 GBW 3.05 20
631.15 W 8.45 29
207.15.135 GBW 3.04 20
207.15.150 GB 3.14 20 300-PushFit 632.125 W 9.27 29
632.15 W 10.84 29
207.2.92 GW 4.33 20
633.15 W 14.65 29
207.2.135 GW 4.41 20 300.125.30 GBW 4.12 25
645.125 W 11.21 29
209.2 GW 3.68 19 300.15.30 GBW 5.10 25
645.15 W 12.30 29
210.125 GBWR 1.60 19 300.2.30 G 8.50 25
651.15 W 15.66 30
210.15 GBWR 1.59 19 301.125.91 GBW 1.31 25
657.15 W 10.15 30
210.2 GBW 2.91 19 301.125.135 GBW 1.31 25
659.15 W 15.72 30
211.125 G 6.68 19 301.15.91 GBW 1.31 25
690.075 W 9.78 30
211.15 G 8.75 19 301.15.135 GBW 1.31 25
691.075 W 10.96 30
211.2 G 9.97 19 301.2.91 G 2.26 25
9250 W 11.10 30
212.125 G 2.84 23 301.2.135 G 2.26 25

40 G - Grey B - Black W - White R - Rustic Brown


Numerical Index
Numerical Index
Code Colour Page Materials BS 6209. Solvent Cement: 125, 250
and 500ml tins.
100 and 100P Terrain Soil System
PVC-u Terrain systems also comply with
Accessories many of the requirements of DIN
200 Terrain Waste System and ISO.
1725.2 S/Steel 41.24 31
1725.3 S/Steel 49.36 31 MuPVC
1725.4 S/Steel 55.60 31
300 Terrain Waste System
Availability
1725.6 S/Steel 106.25 31
1726 2.32 31 Polypropylene
9100.125 8.83 32 For details of local stockists, please
9100.250 12.13 32 contact Sales Support on 01622
500 Terrain Overflow System
9100.500 22.42 32 717811.
PVC-u
9101.125 6.48 32
9101.250 8.30 32
600 Terrain Traps Further information
9104.3 G 3.25 31
Polypropylene
9104.4 GB 3.01 31 and assistance
9104.6 G 5.85 31
9105.500 Blue 12.04 31
9113 B 0.96 32 Quality assurance Terrain products are backed by a
9114 G 1.08 32 comprehensive technical advisory
9115 Self 26.60 31 Terrain is accredited to BS EN ISO service, available to provide advice
9116.4 B 1.66 32 9001:2000 Quality Management and design guidance on all aspects
9116.6 B 3.14 32 Systems. of above and below ground
9119.B B 2.77 32 drainage.
9120 B 2.43 32
9124 B 8.05 32 Certifications Technical services include:
9132.125 B 0.47 32
9132.15 B 0.52 32 The Terrain Automatic Air Soil and waste schematics and
9132.2 B 0.69 32 Admittance Valve is covered by applicable details.
9136.50 10.12 32
British Board of Agrment Specification, product
9136.250 34.91 32
Certificate 97/3421. scheduling and estimating.
9136.500 6.14 32
9149 Red 5.98 32 CAD drawings, including
Standards compliance products and application details
Note: Products marked with * are part
on disk.
of the Terrain Underground range and Terrain systems comply with the
Many products are also
a different discount structure therefore appropriate British and European
available in CAD form for ready
applies. Standard and, where applicable,
incorporation into design
bear the Kitemark:
drawings (Products marked in
the listings). To obtain a disk or
BS 4514:2001. PVC-u Soil Systems,
CD Rom in the appropriate
82, 110 and 160mm soil pipes and
format, simply contact Technical
fittings (partially replaced with BS
Services.
EN 1329-1:2000)
On site advice and problem
BS 4514 is an Internal Claim only.
solving.
Products migrated from BS 4514 to
the new BS EN 1329 standard still Prefabrication and fabrication
comply fully to BS 4514 but can design service.
only be licensed to BS EN 1329
For prompt assistance, please
BS 5254:1976. Polypropylene waste
contact the Terrain Technical
systems, 32, 40 and 50mm waste
Services Department:
pipe and fitting
BS 5255:1989. MuPVC waste Tel: 01622 717811
systems 32, 40 and 50mm waste Fax: 01622 791049
pipes and fittings (partially replaced
with BS EN 1329-1:2000) Tel: 01509 615100
Fax: 08452 760076

G - Grey B - Black W - White R - Rustic Brown 41


Commercial Piping and
Sanitary Systems

Polypipe Terrain

New Hythe Business Park

College Road

Aylesford

Kent ME20 7PJ

Tel: 01622 795200

Fax: 01622 716796

commercialenquiries@polypipe.com

www.polypipe.com

www.terraindrainage.com
Printed on material sourced from sustainable and well managed forests