You are on page 1of 34

PRICE GUIDE

MRL I. 31
AUTOMATION PRODUCTS

Relays & Accessories


GRID
Alstom Grid Presence In India

Alstom Grid India is the market leader in the Indian power transmission sector, with a strong
product portfolio encompassing a full range of locally-made transmission equipment up to
765KV and above, including power transformers (Extra High Voltage 800KV DC and Ultra
High Voltage 1200KV AC). With a 100-year presence in India, more than 3,500 employees
and eight world class manufacturing units, Alstom Grid is future-ready to continue its support
of the rapidly evolving transmission sector in India.

Alstom Grid, one of four sectors of the Alstom Group alongside Alstom Thermal Power,
Alstom Renewable Power and Alstom Transport, has over 100 years of expertise in electrical
grids. Whether for utilities or electro-intensive industries or facilitating the trade of energy,
Alstom Grid brings power to its customer's projects. Alstom Grid ranks among the global top
three in electrical transmission sector with an annual sales turnover of more than 4 Billion
Euro. It has 20,000 employees and over 90 manufacturing and engineering sites worldwide.
At the heart of the development of Smart Grid, Alstom Grid offers products, services and
integrated energy management solutions across the full energy value chain from power
generation, through transmission and distribution grids and to the large end user.
Alstom Grid Presence In India
Contents

1. Important Notes 1

2. Terms and Conditions 2


3. Price of Relays :

Section I - Disc Relays 5


Section II - Induction Cup Relays / Scheme Relays 8
Section III - Hinged Armature Relays 9
Section IV - Static Relays 12
Section V - Relays in MIDOS Housing 16
Section VI - Industrial Relays / Others 16

4. Price of Accessories 20
5. Product Obsoletion 22
6. Numerical Relay Selection 24

Note :
The Abbreviations Std. & Non Std. used in inner columns denote Standard and
Non - Standard respectively
1. Important Notes

I) NOTES
1. Prices given in this Price Guide are subject to change unless our agreement has been obtained to maintain the validity for specified
period and for specific quantities. Reference should be made to us for quoting against specifications from Electricity Boards, Electricity
Supply Undertakings etc, where large quantity of Relays are involved, so that suitable deliveries could be quoted.
2. Prices indicated in the Price Guide will be applicable only for orders received with 100% advance through crossed demand draft.
Otherwise prices ruling at the time of despatch will be applicable.
3. Prices given are ex-works Chennai, exclusive of Sales Tax, Excise Duty and any other levies,Taxes & Duties
4. Relays have been categorised in two parts i.e.Standard and Non-Standard depending on the usage / manufacture (Please note
that delivery for non-standard relays will normally be longer as compared to standard relays.)
5. Please contact us for delivery schedules. Also note that deliveries indicated by us will be reckoned from the date of Receipt of
technically and commercially clear order with advance.
6. Alstom reserves the right to levy cancellation charges in case of any order being cancelled or levy reprocessing charges in respect of
Amendments to specification of relays ordered and where the manufacturing instructions have already been issued.
II) THE MAXIMUM NUMBER OF TERMINALS AVAILABLE ON THE
VARIOUS TYPES OF CASES ARE :
CASE SIZE MAXIMUM NO. OF
TERMINALS
N Vertical 10/15
N Horizontal 12/20
1D Vertical (Single Ended) 10
1D Vertical (Double Ended) 20
1D Vertical (Single Ended) 10
1D Vertical (Double Ended) 20
1D Vertical (Double Ended with Midos Terminal) 48
2D Vertical (Single Ended) 10
2D Vertical (Double Ended) 20
3D Horizontal (Single Ended) 30
3D Vertical (Double Ended) 20
Please note that MIDOS housing has per terminal block 28 terminals.
III) BASIC INFORMATION REQUIRED WITH ORDER :

a) Case:
i. Case size (Drawout or Non-drawout)
ii. Mounting arrangement (only flush type offered as per our standardisation)
b) For Protective Relays
i. C.T.Secondary rating
ii. V.T.Secondary/ Tertiary rating
iii. Setting range
iv. Auxiliary D.C. / A.C. Supply available for electrical flag unit
v. Current or voltage polarised and M.T.A. for directional relays.
c) Auxiliary Relays
i. D.C. / A.C. Coil voltage or Current rating.
ii. Contact voltage and Current rating inductive or resistive
iii. Number of contacts and types self / hand reset; normally open / normally closed, change over.
iv. Connection diagram taking into account the maximum number of available case terminals.
We will recommend the nearest standard connection diagram on receipt of the information
v. Timing range for timer relays.

1
2. Terms and conditions

1. ACCEPTANCE AND TERMS AND CONDITIONS:


(a) these terms and conditions and any amendments thereto are considered accepted by Purchaser unless
notification of rejection is received in writing. (b) By acceptance of these terms and conditions, Purchaser agrees
to be bound by, and to comply with all the terms and conditions of these terms and conditions, including any
supplements thereto, and all specifications and other documents referred to in these terms and conditions.

An acknowledgement of these terms and conditions containing terms and conditions inconsistent with or in
addition to the terms and conditions of these terms and conditions is not binding upon ALSTOM unless
specifically accepted by ALSTOM in writing and ALSTOM hereby objects thereto.

2. INSPECTION / SHORTAGE:
The Purchaser is under a duty whenever possible to inspect the Goods on delivery or on collection as the case
may be. Where the Goods cannot be examined the carriers note or such other note as appropriate shall be
marked not examined. The ALSTOM shall be under no liability for any damage or shortages that would be
apparent on careful inspection if the terms of this clause are not complied with and, in any event will be under no
liability if a written complaint is not delivered to the ALSTOM within Ten (10) days of delivery detailing the alleged
damage or shortage. In all cases where defects or shortages are complained of the ALSTOM shall be under no
liability in respect thereof unless an opportunity to inspect the Goods is supplied to the ALSTOM before any use
is made thereof or any alteration or modification is made thereto by the Purchaser.

3. PART DELIVERY:
Unless otherwise explicitly agreed, Goods will be dispatched as and when ready. If part dispatch is made,
proportionate payment in full becomes due and payable including taxes, duties, levies etc as per the agreed
payment terms.

4. SUSPENSION OF WORK:
In the event of suspension of work due to lack of clear technical or commercial information/ instructions, the
prices shall be revised to cover any extra expenses and a revised delivery commitment shall be obtained by
purchaser from ALSTOM. Any statutory variations during this period shall also be payable by Purchaser.

5. LIMITED WARRANTY:
It is the Purchaser's responsibility to ensure that the Goods are suitable for the purpose to which they are
intended to be used. No representation or warranty is given as to the suitability or fitness of the Goods for any
particular purpose and the Purchaser shall satisfy itself in this respect and shall be totally responsible therefore.
If the Purchaser has any specific requirements for the use of the Goods the Purchaser must notify these
requirements to the ALSTOM in writing before purchasing the Goods. If the Purchaser is unsure as to the
suitability of any Goods for a particular purpose it should consult the ALSTOM prior to purchase. If the Goods are
in such a state as would but for this condition entitle the Purchaser to repudiate the contract and/or claim
damages from the ALSTOM the ALSTOM reserves the right to repair or replace the goods.

6. DELIVERIES:
Deliveries will be made strictly in quantities which will be specified in order received from Purchaser. Title to and
risk of any loss or damage to the goods shall pass from ALSTOM to Purchaser immediately after handover to the
carrier.

2
7. TAXES:
In case of any revision in statutory duties/ taxes/ cess/levies within the contractual period shall apply and shall be
on Purchaser's account as applicable.

8. DELAYED PAYMENT CHARGES:


In case of delay in payment, beyond contractual period, PURCHASER shall be liable to interest as applicable.

9. RETENTION OF TITLE:
All Goods shall be at the Purchaser's risk from the time of delivery but will remain the property of the ALSTOM
until all payment due from Purchaser to ALSTOM has been made in full. The ALSTOM or any of its agents, may
at any time without notice before payment is made in full enter any premises to retake possession of all the
ALSTOM's Goods whether held in the custody of the Purchaser or at any other premises. At all times before
payment is made by the Purchaser in full, the Purchaser shall store or otherwise denote the Goods in respect of
which property remains with the Seller in such a way that the same can be recognised as the property of the
Seller.

10. LIABILITY:
The ALSTOM does not bear responsibility for any defect arising or introduced during the course of storage or
handling of the products. The Purchaser should consult the ALSTOM if doubt exists with regard to the
appropriate storage or handling requirements. The Purchaser cannot claim the benefit of this clause unless;

(i)) he informs the ALSTOM of the relevant defect in writing within 7 working days of discovering it; and

(ii) he returns the goods to the ALSTOM at his own expense.

ALSTOM shall not be liable for any loss of profit, loss of business, damage to the property or any one else,
consequential or indirect loss suffered by the Purchaser whether this loss arises from tort or in any other way.

The ALSTOM's total liability for any one claim or for the total of all claims arising from any one act or default of
the ALSTOM (whether arising from the ALSTOM's negligence or otherwise) shall be limited in amount to the net
purchase price of the products sold to Purchaser by ALSTOM hereunder.

11. DRAWINGS/ DOCUMENTS:


All drawings/ documents are indicative only and descriptions, specifications and other matter are intended to
present general idea of the Goods described. We reserve the right to modify the type reference, design and
particulars of our products without notice.

12. TESTS:
Goods are subjected to routine tests before dispatch. Any specific testes requested by PURCHASER with or
without presence of their representatives/ agents shall be subject to express approval from ALSTOM. It shall
also have an impact on price and delivery which shall be quoted separately upon request.

13. PERFORMANCE:
Figures provided in the documents are based on internal testing. We shall not be liable for damages for failure to
attain these unless specifically guaranteed. PURCHASER is not entitled to reject Goods without providing
reasonable time and opportunity to ALSTOM. In case of entitlement to reject the goods, maximum liability shall
be as per

3
14. FORCE MAJEURE:
The ALSTOM shall not be liable for any failure to deliver the Goods arising from circumstances outside the
ALSTOM's control. Non-exhaustive illustrations of such circumstances would be act of God, war, riot, explosion,
abnormal weather conditions, fire ,flood, strikes, lockouts, Government action or regulations, delay by suppliers,
accidents and shortage of materials, labour or manufacturing facilities. Should the ALSTOM be prevented from
delivering in the above circumstances, it shall give the Purchaser written notice of this fact as soon as
reasonably practicable. If the circumstances preventing delivery are still continuing one month after the
Purchaser receives the ALSTOM's notice, then either party may give written notice to the other cancelling the
order.

15. INSTALLATION:
ALSTOM assumes no obligation to install the products or to place them in operation at Purchaser's premises,
unless specifically stated in writing and signed by an authorized agent of ALSTOM.

16. ARBITRATION:
Any dispute, controversy or claim arising out of or relating to this Invoice or any related Invoice or other
document or the validity, interpretation, breach or termination thereof ("Dispute"), including claims seeking
redress or asserting rights under applicable law, shall, be resolved and finally settled in accordance with the
provisions of the Indian Arbitration and Conciliation Act, 1996 as may be amended from time to time or its re-
enactment (the "Arbitration Act").

17. GOVERNING LAW:


All matters involving the validity, interpretation, and application of these Standard Terms and Conditions of Sale
will be controlled by the law of India.

4
3. Section I - Disc Relays

Relay Application Range Variation Unit Ex-works


Type Description Case Size Chennai Price
in Rs.

CCUM21 AC Reverse Power Relay Std 1 D Vert 23,635

CDD21 Single pole directional IDMT Std 1 D Vert 2N/O S/R 15,375
self powered O/C or E/F relay Std 1 D Vert 2N/O 1N/C H/R 15,855

CDD21 Single pole Directional IDMT dual Non-Std 1 D Vert 19,815


polarised E/F relay adjustable setting 2N/O
S/R E/F20-80% OR 10-40% E/F 1A 0R 5A CT SEC
CDG11 Single pole Non-directional IDMT selfpowered Std 1D Vert 2N/O S/R 5,200
O/C or E/F relay Non-Std 1D Vert. 2N/O 2 N/C H/R 5,640
CDG31 Triple pole Non-directional IDMT self powered Std 3D Horz. 2N/O S/R 14,650
3 O/C or 2 O/C & 1E/F relay Non-Std 3D Horz. 2N/O 2N/C H/R 16,360
Std 3D Vert. 2N/O S/R 15,865
Non-Std 3D Vert. 2N/O 2N/CH/R 17,125
C DG21/ Single pole Non-directional IDMT O/C or Std 1D Vert 2N/O S/R 8,735
CAG17 1 E/F selfpowered relay with instantaneous 1D Vert 2N/O 2N/C H/R 9,175
highset unit CAG17

CDG61/ Triple pole Non-directional IDMT 3 O/C Std 3D Horz 2N/O S/R 25,325
CAG17 or 2 O/C & 1 E/F self powered relay with Non-Std 3D Horz. 2N/O 2 N/C H/R 26,525
instantaneous highset unitCAG 17 Std 3D Vert. 2N/O S/R 26,315
Non-Std 3D Vert. 2N/O 1NC H/R 27,480

CDG11S/T Single pole Non-directional IDMT O/C Std 1D Vert. 6,545


or E/F AC series tripping relay
CDG21S/T Single pole Non-directional IDMT O/C or Std 1D Vert. 10,550
E/F AC series tripping relay with
instantaneous highset unit CAG17
CDG31S/T Triple pole Non-directional IDMT 3 O/C Std 3D Horz. 18,010
or2 O/C & 1 E/F AC series tripping relay Non-Std 3D Vert 20,780

CDG61S/T Triple pole Non-directional IDMT 3 O/C or Std 3D Horz. 30920


2O/C & 1E/F AC series tripping relay with Non-Std 3D Vert. 34,940
instantaneous highset unit CAG17
CDG12 Single pole inverse time (long time delay) stand Std 1D Vert. 2N/O S/R 6,980
by earthfault relay Non-Std 1D Vert. 2N/O H/R 7,445

CDG13 Single pole non-directional very inverse time Std 1D Vert. 2N/O S/R 6,175
O/C or E/F relay Non-Std 1D Vert. 2N/O H/R 7,940

CDG23 Single pole non-directional very inverse Std 1D Vert. 2N/O S/R 10,910
time O/C or E/F relay with instantaneous Non-Std 1D Vert. 2N/O H/R 11,405
highset unit CAG17
CDG33 Triple pole non-directional very inverse time Std 3D Horz. 2N/O S/R 17,670
3 O/C or 2 O/C 1 E/ Frelay Non-Std 3D Horz. 2N/O H/R 19,060
Std 3D Vert. 2N/O S/R 18,940
Non-Std 3D Vert. 2N/O H/R 20,330
CDG63 Triple pole non-directional very inverse time Std 3D Horz. 2N/O S/R 32,160
O/C or E/F relay with instantaneous highset Non-Std 3D Horz. 2N/O H/R 33,570
Unit CAG17 Std 3D Vert. 2N/O S/R 33,485
Non-Std 3D Vert. 2N/O H/R 34,910

5
Relay Application Range Unit Ex-works
Variation
Type Description Chennai Price
Case Size
in Rs.

CDG13S/T Single pole non-directional very inverse time Non-Std 1D Vert. 7,625
O/C or E/F relay for AC series tripping
CDG23S/T Single pole non-directional very inverse time Non-Std 1D Vert. 12,065
O/C or E/F relay with instantaneous highset
unit CAG17 for AC series tripping
CDG33S/T Triple pole non-directional very inverse time Non-Std 3D Horz. 21,995
2 O/C & 1 E/F or 3 O/C relay for AC series Non-Std 3D Vert. 24,540
tripping
CDG63S/T Triple pole very inverse time 3 O/C or 2 O/C & Non-Std 3D Horz. 35,345
1 E/F relay with highset instantaneous unit Non-Std 3D Vert. 36,635
CAG17 for AC series Tripping
CDG14 Single pole non directional extremely inverse Std 1D Vert. 6,970
time O/C OR E/F relay
CDG24 Single pole non-directional extremely inverse Std 1D Vert. 11,180
time O/C or E/F with highset instantaneous
unit CAG17
CDG34 Triple pole non-directional extremely inverse Std 3D Horz. 20,455
time 3 O/C or 2 O/C & 1 E/F relay Non-Std 3D Vert. 21,780
CDG64 Triple pole non-directional extremely inverse Std 3D Horz. 33,160
time 3 O/C or 2 O/C & 1 E/F relay with Non-Std 3D Vert 34,485
instantaneous highset unit CAG17
CDG14S/T Single pole non-directional extremely inverse Non-Std 1D Vert. 8,570
time O/C or E/F relay for AC series tripping
CDG34S/T Triple pole non directional extremely inverse Non-Std 3D Horz. 22,890
time 3 O/C or 2 O/C & 1 E/F relay for AC Non-Std 3D Vert. 25,535
series tripping
CDG24S/T Single pole extremely inverse time O/C or E/F Non-Std 1D Vert. 12,515
relay with instantaneous highset unit
CAG17 for AC Series tripping
CDG64S/T Triple pole non-diectional extremely inverse Non-Std 3D Horz. 36,645
time 3 O/C or 2 O/C & 1 E/F relay with
instantaneous highset unit CAG17 for AC
Series tripping
CDGM22 Single pole O/C relay for overload protection, Non-Std 1D Vert 13,295
having long inverse time characteristic with
instantaneous highset CAG17
CDAG53 Triple pole non-directional combined O/C & Non-Std 3D Horz. 28,170
E/F relay with two CDG 23 O/C units having Non-Std 3D Vert. 29,420
highset instantaneous element CAG17 and
1No. CAG 14 E/F centre unit
CDAG54 Triple pole non-directional combined O/C & Non-Std 3D Horz. 28,760
E/F relay with two CDG 24 O/C units Non-Std 3D Vert. 30,060
having highset instantaneous element
CAG17 and 1 No CAG 14 E/F centre unit

6
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

CDV62 Triple pole voltage controlled non-directional Std 3D Horz. 2N/O S/R 23,215
IDMT O/C relay Std 3D Horz. 2N/O H/R 24,540
Non-Std 3D Vert. 2N/O S/R 24,780
Non-Std 3D Vert. 2N/O H/R 26,070

VDG11 Single Pole Self powered inverse time over Std 1D Vert. 110V AC 8,820
voltage relay Std 1D Vert. 250VAC / 440VAC 12,475
VDG13 Single pole inverse time under voltage relay Std 1D Vert 110V AC 9,765
Std 1D Vert.250V AC / 440V AC 12,905
VDG14 Single pole inverse time neutral voltage Std 1D Vert. 10,815
displacement relay

7
3. Section II
Iinduction Cup Relays / Scheme Relays

Relay Application Range Variation Unit Ex-works


Type Description Case Size Chennai Price
in Rs.

HORM Feeder Protection relay set using private pilots Std 10,8,790

with facility to supervise the healthiness of


pilots comprising of;
Relay for sending end 1 D Vert
Relay for receiving end 1 D Vert
Injection transformer unit 1D Vert
Measuring + Pilot supervision relay 1D Vert

8
3. Section III - Hinged Armature Relays

Relay Application Range Variation Unit Ex-works


Type Description Case Size Chennai Price
in Rs.

CAEM21 Self Powered battery earthfault relay Std 1D Vert. 14,900

CAEM33 Second rotor earth fault relay Std 1D Vert 47,070

CAG12 AC instantaneous O/C or E/F relay Std N Vert. 3,615


Std 1D Vert. 5,125

CAG14 Single pole AC instantaneous high stability Std 1D Vert. 7,415


circulating current relay (1 x Metrosil if
required can be offered at extra price)
CAG14 Single pole AC instantaneous high stability Std 1D Vert. 7,875
with Stab circulating current relay with 1000 ohms resistor
Resistors (1 x Metrosil ifrequired can be offered
at extra price)
CAG34 Triple pole AC instantaneous high stability Std 1D Vert. 16,460
circulating current relay (3 x Metrosil if
required can be offered at extra price)
CAG34. Triple pole AC instantaneous high stability Std 1D Vert 17,875
with Stab circulatig current relay with 1000 ohms
Resistors (3 x Metrosil if required can be
offered at extra price)
CAG17 Single pole AC instantaneous O/C relay Std 1D Vert. 7,110

CAG37 Triple pole AC instantaneous O/C relay Std 1D Vert. 13,600

*VAA11 Single element voltage operated auxiliary Std N Vert. 2,440


relay with S/R contacts
*VAA21 Two element voltage operated auxiliary relay Std N Vert 3,635
with S/R contacts Std N Horz 3,970
Special aux.Relay to provide flashing supply Std N Vert 3,835
to the facia lamp and operates the audible Std N Vert 3,580
alarm in our standard electro-mechanical
annunciation scheme
*VAA31 Three element voltage operated auxiliary Std N Horz 4,140
relay with S/R contacts Std 1 D Vert 6,070
Special aux.Relay to provide flashing supply Std N Horz 5,230
to the facia lamp and operates the audible
alarm in our standard electro-mechanical
annunciation scheme

9
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

*VAA12 Single element voltage operated auxiliary relay Std N Vert 2,395
with combined S/R & H/R contacts.
*VAA22 Two element voltage operated auxiliary Std N Horz 3,970
relay with combined S/R & H/R contacts.
*VAA32 Three element voltage operated auxiliary Std N Horz 4,440
relay with combined S/R & H/R contacts. Std 1D Vert 6,300
*VAA13 Single element voltage operated auxiliary Std N Vert 2,395
relay with H/R contacts
Std N Vert. 3,520
*VAA23 Two element voltage operated auxiliary Std N Horz 4,000
relay with H/R contacts Non-Std 1 D Vert 3,800
Non-Std 1 D Vert 5,515
*VAA33 Three element voltage operated auxiliary Std N Horz 4,360
relay with H/R contacts Non-Std 1D Vert 6,240

**Note : The listed models of VAA are DC Models 430


AC operated VAA relays are at extra price/per unit
**VAA models with slug extra price (Per slug ) 780
**VAA models with blow out magnet (BOM ) 170
at extra price ( per BOM )
**VAA models are with four pair of contacts for 450
Additional 2 pair of contacts extra price
For any other special applications like supply fail etc. revert to unit for details.

10
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

VAEM22 Negative potential biased earth Std 1D Vert. 18,330


leakage relay
VAEM21 Rotor earthfault relay Std 1D Vert. 16,490
VAG11 Single pole instantaneous no-volt Std N Vert. 2,320
relay with fixed setting Std N Horz 3,265
VAG11 Single pole instantaneous under voltage or Std N Vert. 2,645
over voltage relay with fixed setting Std N Horz 3,295
Std 1D Vert. 4,235
VAG21 Single pole instantaneous no-volt or under Std N Horz 3,810
voltage or over voltage relay Std 1D Vert. 5,170
Z Note: Extra Price for high drop-off/ pick-up ratio of 1,300
U/V relays having special setting other than 30 to
60% std. Range.)
VAGM22 Single pole instantaneous under voltage or Std 1D Vert. 110 V AC 7,520
over voltage self powered relay Std 1D Vert 250/440 V AC 10,345
with adjustable settings.
VAG21/ Dead-line charging relays for use with Non-Std 1D Vert. 6,870
VAA11 auto-reclose relays
VAG21/ Dead-line charging relays for use with Non-Std 1D Vert. 7,760
VAA21 auto-reclose relays
VAG31 Three element instantaneous Std N Horz 7,770
under voltage relay
VAJC11 Single element voltage operated control Std NV 7,590
relay with electrical reset contacts Std 1D Vert 8,705

VAJS13 Single element high seepd tripping relay with Std N Vert. 2,525
self reset contacts

VAJS23 Two element high speed tripping Std N Horz 4,365


relay with self reset contacts
VAJH13 Single element high speed tripping Std N Vert 2,365
relay with hand reset contacts

VAJH23 Two element high speed tripping Std N Horz 4,495


relay with hand reset contacts
VAJHM13 Single element high speed tripping Std N Vert 2,670
relay with hand reset contacts
suitable for coil supervision
VAJHM23 Two element high speed tripping Std N Horz 4,495
relay with hand reset contacts
suitable for coil supervision
VAJHM33 Three element high speed tripping Std 1 D Vert 11,320
relay with hand reset contacts
suitable for coil supervision

11
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

VAJHM53 Five element high speed tripping relay with Std 1 D Vert 14,135
hand reset contacts suitable for coil
supervision
VAPM31 Triple pole fuse failure
with RES (Sp.Model ) relay with Resistors Std 1D Vert. 9,870

VAX21 Trip supply supervision relay Std N Horz 4,170


Std 1D Vert 5,700

VAX31 Trip circuit supervision relay Std N Horz 4,780


Std 1D Vert 6,300

VAWA12 Single element interposing relay Non-Std N Vert 2,825


Non-Std 1D Vert 5,020

VAWA22 Two element interposing relay Non-Std N Horz 5,105


Non-Std 1D Vert. 6,870
Semaphore Indicator

VAM12 Std 1 "dia 2 way & off 2,160

VAM22 Std 2 "dia 2 way& off 2,485


Test Block/ Test Plug

MPB Test plug Std 3,435

MPG Universal Test Block Std 4,275

12
3. Section IV - Static Relays

Relay Application Range Variation Unit Ex-works


Type Description Case Size Chennai Price
in Rs.

CTMM501-510 Static motor protection relay for motors Std 2D Vert 44,025
controlled by circuit breakers providing
thermal instantaneous three phase
over current unbalance and single
phasing earthfault and separate built-in
stalling protection
CTNM12 Static definite time negative phase Std N Horz 6,845
sequence current relay for single
phasing & unbalanced detection
CTU12 Static definite time single pole Std 1D Vert 12,075
O/C or E/F relay
CTU32 Three pole static 3 O/C or 2 O/C Std 1D V 15,825
& 1 E/F relay
CTU62 Three pole definite time static O/C relay Std 1D Vert 22,890
instantaneous with highset
CTU15 Single pole sensitive definite time Std 1D Vert 26,020
static E/F relay
CTUM15 Single pole definite time static sensitive Std N Horz 9,805
E/F relay 1 D Vert 15,185

DTH31 Three phase harmonic restraint differential 3D Vert 60,420


relay for protection of 2 winding
transformers with fixed setting.

13
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

GTTM22 Inverse time static overfluxing relay for Non-Std 1D Vert. 71,505
transformers(To refer Chennai works before
quoting for these relays in large quantity.)
SKD11 Static check synchronising relay Std 1D Vert 51,260

SKD with Static check synchronising relay Non-Std 1D Vert 64,715


Power Pack suitable for 110V AC
SKE11 Static check Synchronising relay Std 1D Vert 51,260
for Generator protection
SKE with Static check synchronising relay Non-Std 1D Vert 64,715
PowerPack suitable for 110VAC
VTNM12 Static negative phase sequence voltage relay Std N Vert 6,600

VTT11 Static time delay relay (delay on pickup) Std N Horz DCS/R Contacts 5,355

STANDARD TIMINGS RANGES:

0.05 - 0.5 Second Std 1D Vert DC S/R Contacts 7,350


0.1 - 1.0 Second Std N Horz AC S/R Contacts 7,140
0.5 - 5.0 Second Std 1D Vert AC S/R Contacts 8,485
1.0 - 10.0 Second Non-Std N Horz DC H/R Contacts 6,145
2.5 - 25 Second Non- Std 1D Vert DC H/R Contacts 7,475
Non- Std N Horz. AC H/R Contacts 7,550
Non-Std 1 D Vert. AC H/R Contacts 10,240
VTT12 Static time delay relay (delay on drop off) Std N Horz DC 5,355
STANDARD TIMINGS RANGES:
0.05 - 0.5 Second Std N Horz AC 7,140
0.1 - 1.0 Second Std 1D Vert DC 7,350
0.5 - 5.0 Second
Std 1D Vert AC 8,485
1.0 - 10.0 Second
2.5 - 25 Second

14
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

VTT14 Static definite time relay delay Std N Horz DC 9,250


on pick-up Non-Std N Horz AC 11,065

VTT15 Static definite time relay delay on Std N Horz DC 9,250


drop-off Non-Std N Horz AC 11,070
Note: Std Models for VTT 12, VTT14 and VTT15 are with
3 pair contacts Extra price for the additional pair 250

VTUM21 Static definite time U/V relay Std 1D Vert 12,610

VTU31 Static combined definite time & Std 1D Vert 17,165


instantaneous over voltage relay
VTX31 CT Bus wire protection pilot Std 1D Vert 20,695
supervision relay
Note : Extra Price for 4 pairs H/R contacts instead of S/R contacts 800

15
3. Section V - Relays in MiDOS Casing

Relay Application Range Variation Unit Ex-works


Type Description Case Size Chennai Price
in Rs.

VOLTAGE OPERATED AUXILIARY RELAYS WITH S/R CONTACTS


MVAAM11 Single element relay with 2make 2 Std Size2 4,255
change-over output contacts
MVAAM21 Two element relay with 4 change-over Std Size2/3 6,325
total output contacts
MVAAM31 Three element relay with 4 change-over Std Size2/3/4 7,155
total output contacts

VOLTAGE OPERATED AUXILIARY RELAYS WITH H/R CONTACTS AND FLAG.


MVAAM13 Single element relay with 2 make 2 Std Size2 4,200
change-over output contacts

MVAAM23 Two element relay with 4 make 4 Std Size4 5,950


change-over total output contacts

OTHER PROTECTIVE RELAYS


MVAGM21 Instantaneous Under Voltage Relay Std Size4 6,445

MCAG14 Single pole high stability circulating Std Size3 9,530


current relay with S/R contacts & H/R flag
( 1x Metrosil if required can be offered
at extra Price)
MCAG34 Triple pole high stability circulating current Std Size6 21,170
relay with S/R contacts & H/R flag
( 3 x Metrosil if required can be offered
at extra Price)

MVAXM21 Trip supply supervision relay having Std Size3 6,295


S/R contacts & reverse flag

MVAXM31 Trip circuit supervision relay with pre-closing Std Size4 6,995
and post- closingsupervision, having
S/R contacts & reverse flag

MFVUM12 Digital Over/Under Freq Protection Relay with Std Size4 42,880
built-in Time Setting Range, Single Stage relay

MFVUM22 Digital Over/Under Freq ProtectionRelay Std Size4 54,050


With built - in TimeSetting Range - Two stage relay

16
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

MBCH12 Single phase 2 winding transformer Std Size4 24,065


differential relay with 2 biased inputs
MBCH13 Single phase 3 winding transformer Std Size4 26,045
differential relay with 3 biased inputs
Note : ICT, test blocks and any other Accessories as required may be procured
seperately. The price declared above do not cover for these additional items .
Also note that a set of 3nos of MBCH will be required for the three phase
transformer protection
MCTI40-L Local breaker back-up relay three pole Std Size6 35,720

MVAJM11 Single element voltage operated tripping Std Size2 4,060


relay with self-reset contacts
MVAJM13 Single element voltage operated tripping Std Size2 4,430
relay with hand-reset contacts
MVAJM15 Single element voltage operated tripping Std Size2 4,430
relay (high burden) with hand reset contacts
MVAJM14 Single element voltage operated control Std Size4 10,760
relay with electrical reset contacts
MVAJM25 Two element voltage operated tripping relay Std Size4 5,840
(high burden) with H/R contacts
MVAJM41 Four element tripping relay with Std Size6 13,390
S/R contacts no flag
MVAJM45 Four element tripping relay with Std Size8 14,100
H/R contacts and flag
MVAJ051-L Self Reset High or Low Burden Tripping Std Size2 19,875
relay with Instantaneous Cut Off contact,
5 Standard O/P Contacts.
MVAJ053-L Hand Reset High or Low Burden Tripping Std Size2 19,875
relay with Instantaneous Cut Off contact,
5 Standard O/P Contacts.
MVAJ054-L Electrically Reset High or Low Burden Std Size2 20,565
Tripping relay with Instantaneous Cut
Off contact, 5 Standard O/P Contacts.
MVAJ055-L Hand and Electrically Reset High or Low Std Size2 21,095
Burden Tripping relay with Instantaneousor
delayed Cut Off contact, 5 Standard O/P
Contacts.
MVAJ101-L Self Reset High or Low Burden Tripping Std Size2 25,440
relay with Instantaneous or delayed Cut Off
contact10 Standard O/P Contacts.
MVAJ103-L Hand Reset High or Low Burden Tripping Std Size2 25,440
relay with Instantaneous or delayed Cut
Off contact,10 Standard O/P Contacts.

17
Relay Application Range Variation Unit Ex-works
Type Description Case Size Chennai Price
in Rs.

MVAJ104 -L Electrically Reset High or Low Burden Std Size2 26,605


Tripping relay with Instantaneous or
delayed Cut Off contact,
10 Standard O/P Contacts.
MVAJ105 -L Hand and Electrically Reset High or low Std Size2 27,665
Burden Tripping relay with Instantaneous or
delayed Cut Off contact, 10 Standard
O/P Contacts.

MVAJ201 -L Self Reset High or Low Burden Tripping Std Size4 43,145
relay with Instantaneous or delayed Cut Off
contact 20 Standard O/P Contacts.

MVAJ203 -L Hand Reset High or Low Burden Tripping Std Size4 43,145
Relay with Instantaneous or delayed Cut Off
contact,20 Standard O/P Contacts.

MVAJ204 -L Electrically Reset High or Low Burden Std Size4 45,900


Tripping relay with Instantaneous or delayed
Cut Off contact,20 Standard O/P Contacts.

MVAJ205 -L Hand and Electrically Reset High or Low Std Size4 46,430
Burden Tripping relay with Instantaneous
or delayed Cut Off contact, 20
Standard O/P Contacts.

MVAPM32 Voltage selection relay with self-reset Std Size4 11,955


contacts and H/R flag

MVTTM14 Static digital time delay relay,delayed on Std Size3 13,060


pick-up

MVTTM15 Static digital time delay relay, delayed Std Size3 11875
on drop-off
MCTGM21 Static inverse time single phase O/C or E/F Std Size4 19,560
relay with standard inverse time
characteristic supplimented with a built-in
instantaneous high set unit

18
3. Section V I - Industrial Relays/Others

Relay Application Range Variation Unit Ex-works


Type Description Case Size Chennai Price
in Rs.

TimEE Static industrial Timers with RQT 1,725


Range and Mode Selection
as detailed below.

Timing Input Model


Range Voltage Number
24 V AC/DC RQT 0004 095
0 . 1 - 1 Secs. 30 V AC/DC RQT 0004 098
48 V AC/DC RQT 0004 100
0 . 4 - 4 Secs. 110 V AC/DC RQT 0001 095
125 V AC/DC RQT 0005 095
3 - 30 Secs.
220 V AC/DC
24 - 240 Secs. RQT 0002 095
220/240 V AC/DC
24 V AC/DC
1 - 10 Secs. RQT 0004 096
24/32V AC/DC
4 - 40 Secs. 110 V AC/DC RQT 0001 096
30 - 300 Secs. 220V AC/DC
4 min.- 40 min. 220/240V AC/DC RQT 0002 096
24V AC/DC RQT 0004 097
6 - 60 Secs.
24 - 240 Secs. 110V AC/DC RQT 0001 097
3min. - 30 min.
220V AC/DC
RQT 0002 097
0.4hr. - 4 hrs. 220/240V AC/DC

19
4. Price of Accessories Standard
ODS Switch Models

Unit Ex-works
Sl ODS Model No. Description Chennai
No. Price in Rs.

1. S02LF120SRPM101 ODS 2 WAY 120 LOCK FREE SPRING RETURN 1840


2. S02N120SRPM101 ODS 2 WAY 120 NON LOCK SPRING RETURN 1375
3. S04LF120SRPM101 ODS 4 WAY 120 LOCK FREE SPRING RETURN 2050
4. S04LF120SRPM117 ODS 4 WAY 120
LOCK FREE SPRING RETURN 2050
5. S04LF120SRSL2PM122 ODS 4 WAY 120 LOCK FREE SPRING RETURN 2605
WITH SEQUENCE + 2 BELL ALARM
6. S04LF120SRSPM104 ODS 4 WAY 120 LOCK FREE SPRING RETURN 2100
WITH SEQUENCE
7. S04LF90SPPM102 ODS 4 WAY 90 LOCK FREE STAY PUT 1680
8. S04N120SRPM101 ODS 4 WAY 120 NON LOCK SPRING RETURN 1440
9. S04N90SPPM101 ODS 4 WAY 90 NON LOCK STAY PUT 1230
10. S06LF120SRL2PM111A ODS 6 WAY 120 LOCK FREE SPRING RETURN 2815
+ 2 BELL ALARM
11. S06LF120SRSPM105 ODS 6 WAY 120 LOCK FREE SPRING RETURN 2375
WITH SEQUENCE
12. S06LF90SPPM107 ODS 6 WAY 90 LOCK FREE STAY PUT 1755
13. S06N120SRL2PM111 ODS 6 WAY 120 NON LOCK SPRING RETURN 2130
+ 2 BELL ALARM
14. S06N120SRPM104 ODS 6 WAY 120 NON LOCK SPRING RETURN 1670
15. S06N120SRSL2PM124 ODS 6 WAY 120 NON LOCK SPRING RETURN 2195
WITH SEQUENCE + 2 BELL ALARM
16. S06N120SRSPM116 ODS 6 WAY 120 NON LOCK SPRING RETURN 1735
WITH SEQUENCE
17. S06N90SPPM102 ODS 6 WAY 90 NON LOCK STAY OUT 1345
18. S08LF120SRSL2PM123 ODS 8 WAY 120 LOCK FREE SPRING RETURN 3235
WITH SEQUENCE + 2 BELL ALARM
19 S08LF120SRSPM118 ODS 8 WAY 120LOCK FREE SPRING RETURN 3140
WITH SEQUENCE
20. S08LF90SPPM102 ODS 8 WAY 90 LOCK FREE STAY OUT 2310
21. S08LT120SRSL2PM108 ODS 8 WAY 120 LOCK TRAPPED SPRING RETURN 3235
WITH SEQUENCE + 2 BELL ALARM
22. S08LT120SRSL2PM123 ODS 8 WAY 120 LOCK TRAPPED SPRING RETURN 3530
WITH SEQUENCE + 2 BELL ALARM
23. S08N120SRSL2PM123 ODS 8 WAY 120 NON LOCK SPRING RETURN 3065
WITH SEQUENCE + 2 BELL ALARM
24. S08N120SRSL2PM124 ODS 8 WAY 120 NON LOCK SPRING RETURN 3065
WITH SEQUENCE + 2 BELL ALARM
25. S08N135SPPM103 ODS 8 WAY 135 NON LOCK STAY PUT 1690

20
Unit Ex-works
Sl Chennai
ODS Model No. Description.
No. Price in Rs.

26. S08N90SPPM102 ODS 8 WAY 90 NON LOCK STAY PUT 1690


27. S10LT180SPPM107 ODS 10 WAY 180LOCK TRAPPED STAY PUT 2520
28. S10N90SPPM126 ODS 10 WAY 90 NON LOCK STAY PUT 2100
29. S12LF180SPPM108 ODS 12 WAY 180 LOCK FREE STAY PUT 2720
30. S12N120SRSL4PM177 ODS 12 WAY 120 NON LOCK SPRING RETURN 3730
WITH SEQUENCE + 4 BELL ALARM
31. S14N120SRSL4PM102 ODS 14 WAY 120 NON LOCK SPRING RETURN 5050
WITH SEQUENCE + 4 BELL ALARM
32. S16LF90SPPM103 ODS 16 WAY 90 LOCK FREE STAY PUT 4105
33. S16N120SRL2PM101 ODS 16 WAY 120 NON LOCK SPRING RETURN 5410
+2 BELL ALARM
34. S20N90SPPM106 ODS 20 WAY 90 NON LOCK STAY PUT 3875
35. S22N120SRL2PM108 ODS 22 WAY 120 NON LOCK SPRING RETURN 6845
+ 2 BELL ALARM
36. S30LT90SPPM105A ODS 30 WAY 90 LOCK TRAPPED STAY PUT 7045

37 S02N120SRSPM102 ODS 2 WAY 120 NON LOCK SPRING RETURN


WITH SEQUENCE 1450
38 S04N120SRSPM106 ODS 4 WAY 120 NON LOCK SPRING
RETURN WITH SEQUENCE 1550
39 S04N90SPPM103 ODS 4 WAY 90 NON LOCK STAY PUT 1220
40 S06LF120SRSL2PM106 ODS 6 WAY 120 LOCK FREE SPRING RETURN
WITH SEQUENCE + 2 BELL ALARM 2680
41 S08N120SRSL2PM115 ODS 8 WAY 120 NON LOCK SPRING RETURN
WITH SEQUENCE + 2 BELL ALARM 3050
42 S10LT90SPPM104 ODS 10 WAY 90 LOCK TRAPPED STAY PUT 3000
43 S10N120SRL2PM104 ODS 10 WAY 120 NON LOCK SPRING
RETURN + 2 BELL ALARM 3650
44 S16N120SRL2PM102 ODS 16 WAY 120 NON LOCK SPRING 5150
RETURN + 2 BELL ALARM
45 S16N180SPPM103 ODS 16 WAY 180 NON LOCK STAY PUT 3650
46 S24LF135SPPM101 ODS 24 WAY 135 LOCK FREE STAY PUT 5500

Note :For details on special Models revert to unit.


Metrosil
Sl.No. Type reference Description. Unit Ex-works
Chennai Price in Rs.
1. MET 1088 ( FOR 1 AMP ) METROSIL FOR SECONDARY RATING 11000
1 AMPERE (SINGLE POLE )
2. MET 1196 ( FOR 5 AMPS ) METROSIL FOR SECONDARY RATING 11000
5 AMPERES (SINGLE POLE )
Note : The above offered Metrosils are Single pole.
Thus for 3 phase applications consider 3 x single pole Metrosil
21
5. Product Obsoletion

Sl Product Application Last Order Extinct Functionas


No. Book Date Date Equivalent

Single pole directional IDMT O/C or E/F relayWith June 2010 June 2011
01. CDD 31 P 141
non-directional instantaneous highset CAG 17

Single pole directional IDMT O/C or E/F relay with June 2010 June 2011 P 141
02. CDD 41
non-directional instantaneous highset CAG 17

CDGM 12 Single pole O/C relay for overload protection June 2010 June 2011 P 141
03.
Portable overcurrent test kit complete with June 2010 June 2011 No Eqvt.
CFB One one number test plug

04. Static single pole instantaneous sensitive June 2010 June 2011 CTUM15
CTIGM15 Earth fault relay
Static motor protection relay for motors June 2010 June 2011 CTMFM401-410
05. CTMFM401-410 Controlled by fused contactors

CTNM 31 Static negative phase sequence relay Expired-order June 2011 P 141
06. Book closed
CTU 52 Definite Time Over Current Protection Expired-order Dec. 2010 MiCOMP111, P12X
07. book closed
Three phase harmonic restraint differential Expired-order Dec. 2011
08 DTH 32 Relat for orotection of 3 winding transformer MBCH
book closed
09. FAC 14 Single pole high impedence differential relay June 2010 Dec. 2011 MFAC 14

10. FAC 34 Single pole high impedence differential relay June 2010 Dec. 2011 MFAC 34

GTT 21 Definite Time Overfluxing relay for transformer Sept. 2010 Sept.2011 GTTM22
11.
Static inverse time single phase O/C or E/F Sept. 2011 Sept.2011 MCTGM21
MCTGM 11 relay with standard inverse time characteristic
12.
Four element relay with 8 change- overtotal Sept.2010 Sept.2011 No Eqvt.
13. MVAAM 41 Output contacts
14. Five element relay with 8 change- overtotal Sept.2010 Sept.2011 No Eqvt.
MVAAM 51 output contacts
15. Six element relay with 8 change- overtotal
MVAAM 61 output contacts Sept.2010 Sept.2011 No Eqvt.

16. RQE Sensitive earth leakage relay June.2010 June.2011 CTUM 15


Voltage operated single phasing
RQS June.2010 June.2011 VTNM 12
and unbalance preventor for motors
17.
VAA11- N Horz.& Single element voltage operated
VAA11 - N Vert
18. 1D Vert Auxiliary relay with S/R contacts

19. VAA11 Plug in Voltage operated plug in auxiliary Sept.2010 Sept.2011 No Eqvt.

20. VAA121 Special auxiliary relay for use initiating


contacts in our standard with six Sept.2010 Sept.2011 No Eqvt.
21. electromechanica annunciation scheme
VAA41 Four element relay with flag Sept.2010 Sept.2011 VAA 31/MVAAM 31

22. VAA 51 special auxiliary relay for voltage selection Sept.2010 Sept.2011 VAA 21
23.
VAA 61 special auxiliary relay for use with three
initiating contactsin our standard Sept.2010 Sept.2011 VAA 31x2
electromechanica annunciation scheme

22
Sl Product Application Last Order Extinct Functionas
No. Book Date Date Equivalent

24. VAA 81 special auxiliary relay for use with four


initiating contactsin our standard Sept. 2010 Sept.2011 VAA 31x2
electromechanica annunciation scheme

25. VAG 31 1D Vert Three element instantaneous under voltage relay Sept.2010 Sept.2011 VAG31 -N horz
26. VAGM 23 Single pole instantaneous under voltage relay Sept.2010 Sept.2011 VAGM22 (40 -80%
variable drop-off and pick-up voltage settings. Setting range)or P92x
Electromechanica annunciation scheme
27. VAGM 61 Voltage balance relay for use in generator Sept.2010 Sept.2011 MVAP22,MVAPM 32
protection
28. VA JH13 N Horz. Single element high speed tripping relay with VAJH 13 - N Vert
Hand reset contacts suitable for Sept.2011
& 1D Vert Feb.2011
coil supervision
29. VAJH231D Vert Two element high speed tripping relay with Sept.2011 Feb.2011
VAJH 23 - N Vert
hand reset contacts
30. Two element high speed tripping relay with Sept.2011
VAJHM13N Horz. hand reset contacts suitable for Feb.2011 VAJHM 13 - N Vert
& 1D Vert coil supervision
31. VAJHM231DVert Two element high speed tripping relay with Sept.2011 Feb.2011 VAJHM 23 - N
hand reset contacts suitable forcoil supervision

32. VAJS 13 N Horz. Single element high speed tripping relay with VAJS 13 - N Vert
Self reset contacts Sept.2011 Feb.2011
& 1D Vert
33. VAJS 231D Vert Two element high speed tripping relay with Sept.2011 Feb.2011 VAJS 23 -N Horz
Self reset contacts

34. VAPM311AF21A Triple pole fuse failure relay VAPM 31 1A22A


Feb.2011 Feb.2011 ( nothing but VAPM31
AF21A+external resistor
35. VARM111 High speed single shot single/three phase
Auto-reclose relay with separate dead time Sept.2011 Sept.2011 Inbuilt function of
for phase and earth faults. numerical relays

36. Static instantaneous U/V relay June.2010 June.2011 VAGM22 (40-80%


VTIGM 12 Setting range)or p92x
37. VTU 21 Static definite time O/V relay June.2010 June.2011 VTU 31
38. Static definite time U/V relay June.2010 June.2011 VTUM 21x3,P92x
VTUM 61 for three phase application
39. WCDM 11 Sensitive reverse power relay Sep.2010 Sep.2011 P127,P14x
40. WCDM 13 Sensitive low forward power relay Sep.2010 Sep.2011 P127,P14x
41. YCGF 11 Field failure relay June.2010 June.2011 inbuilt in P34x
42. ZFB Portable distance relay test kit complete with June.2010 June.2011 No Eqvt.
ICTs and two number test plugs

Note : - Revert to unit for prices, against spare requirement of above listed Relays

23
MiCOM ALSTOM Protection
AGILE Feeder Management IEDS

ANSI Code Function P14NB P14NZ P14DB P14DG P14DL P14DZ P94VB P94VP
Nion Directional Directional Voltage &
Frequencx

50 Definite time overcurrent 6 6 6 6 6 6


50N Neutral/Earth definite time overcurrent 4 4 4 4 4 4
51 IDMT overcurrent 3 3 3 3 3 3
51N Neutral/Earth IDMT overcurrent 2 2 2 2 2 2
50/51SEF Sensitive earth fault 4 4 4 4 4 4
51V Voltage controlled overcurrent . . . .
50 SOTF Voltage restrained overcurrent . . .
68 Switch on to fault . . . . . .
In rush blocking . . . . . .
Cold load pick up . . . . . .
Load encroachment supervision (Load blinders) . .
HIF High impedance earth fault . .
46 Negative sequence overcurrent 4 4 4 4 4 4
46BC Broken conductor . . . . . .
Programmable curves 4 4 4 4 4 4
67 Directional phase overcurrent 6 6 6 6
67N Directional neutral overcurrent 4 4 4 4
Sensitive directional earth faul 4 4 4 4
Watt metric earth fault . . . .
Blocking scheme . . . . . .
37 Undercurrent detection (low load) . . . . . .
32 Phase directional power (Forward/Reverse/Under/Over 2 2 2
49 Thermal overload . . . . . .
50BF CB failure 2 2 2 2 2 2
21FL Fault locator . .
27 Under voltage 3 3 3 3 3 3
59 Over voltage 3 3 3 3 3 3
59N Residual over voltage 3 3 3 3 3 3
47 Negative sequence over voltage . . . . . .
Dv/Dt Rate of change of voltage 4 4 4
79 Auto reclose (number of shots) 4 4 4
25 Check synchronising . . . . .
81O Over frequency 9 9 9 9 9 9
81U Under frequency 9 9 9 9 9 9
81V Under voltage blocking of frequency protection . . . . . .
81 df/dt Rate of change of frequency with opitonal frequency 9 9 9 9 9 9
81Rf Supervision and averaging
81RAV
81R Frequency restoration 9 9 9
64N Restricted earth fault . . . .
87B High impedance busbar . .
PSL Programmable scheme logic . . . . . . . .
86 Latching output contacts (Lockout) . . . . . . . .
VTS VTSupervision . . . .
CTS CTSupervision . . . .
DCSupply supervision . . . . . . . .
CBCondition monitoring . . . . . .
Setting groups 4 4 4 4 4 4 4 4

* Prices Available on Request

24
MiCOM ALSTOM Protection
Overcurrent & Feeder Management Relays

Device P141 P142 P143 P145

CT inputs 5 5 5 5
VT inputs 3 3 3/4 3/4
Opto inputs (max)1 8 16 32 32
Output contacts (max)1 7 15 30 32
Function keys/Hotkeys 2 2 2 12
Interlocking logic X X X X

Protection
Autoreclose 79 X X X X
Check synchronising 25 - - X X
3 Phase overcurrent 50/51P X X X X
Ground fault 50/51N X X X X
Phase directional 67P X X X X
Ground fault directionalr 67N X X X X
Sensitive directional earth fault 67N X X X X
Wattmetric Earth fault 67W X X X X
Neutral Admittance YN X X X X
Restricted Earth fault 64 X X X X
Voltage dependent overcurrent 51V X X X X
Negative sequence overcurrent 46 X X X X
Thermal overload 45 X X X X
Undercurrent 37 X X X X
Over/Under Voltage 27/59 X X X X
Residual overvoltage 59N X X X X
Negative sequence over voltage 47 X X X X
Over/Under frequency 810U X X X X
Rate of change of frequency 87R X X X X
Lock out 86 X X X X
Directional Power 32 X X X X
Circuit breaker failure 50BF X X X X
Broken conductor 46BC X X X X
Voltage Transformer Supervision VTS X X X X
Current Transformer Supervision CTS X X X X
Cold load pick-up X X X X
Inrush blocking X X X X
Switch on to fault SOTF X X X X
Circuit breaker monitoring X X X X
Trip Circuit Supervision TCS X X X X
Inter Micom X X X X

* Prices Available on Request

25
MiCOM ALSTOM Protection
Motor & Generator Management Relays

Device P241 P242 P243 P341 P342 P343 P344 P345 P346
CT inputs 4 4 7 4 5 8 8 9 8
VT inputs 3 3 3 4 4 4 5 6 4
Opto inputs (max) 8 16 16 16 24 32 32 32 32
Output contacts (max) 7 16 16 15 24 32 32 32 32
RTDs (optional) 10 10 10 - 10 10 10 10 10
Analogue (optional) 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4
Function keys/Hotkeys X X X X X X X X X
Interlocking logic X X X X X X X X X
Protection
Motor Protection
Short circuit 50/51 X X X
Motor differential 87M X
Locked rotor 50S/51SLR/51S X X X
Reverse power 32R X X X - - - - - -
Reacceleration/LVride-through/Autorestart 27LV X X X - - - - - -
Startup monitoring/Excessive long start 66/48/51 X X X - - - - - -
Negative sequence overvoltage 47 X X X - - - - - -
Out of step 55 X X X - - - - - -
Loss of load 37 X X X - - - - - -
Under current 37P/37N X X X - - - - - -
Unbalance/Lock-out 30/46/86 X X X - - - - - -
Speed switch inputs 14 X X X - - - - - -
Anti back spin 27ABS X X X
Generator protection
Generator/Transformer differential 87GT - - - - - X X X X
Check synchronising 25 - - - - X X X X X
Interurn/split phase 50DT - - - - - X X X X
Under impedence 21 - - - - X X X X X
Polr slipping 78 - - - - - X X X -
Directional power 32 - - - X X X X X X
Loss of field 40 X X X - X X X X X
Restricted earth fault 64 - - - - X X X X X
100 stator earth fault 3rd harmonic 27TN/59TN - - - - - X X X -
100 stator earth fault low freq injector 64S - - - - - - - X -
Over fluxing 24 - - - - X X X X X
Unintentional energisation at standstil 50/27 - - - - X X X X X
Voltage opendent O/c 51V - - - - X X X X X
Rotor earth fault 64R - - - - X X X X X
Auxillary Functions
Phase overcurrent 50/51P X X X X X X X X X
Phase directional 67P - - - X X X X X X
Ground fault 50N/51N X X X X X X X X X
Sensitive directional earth fault 67N X X X X X X X X X
Wattmetric earth fault 64N/32N X X X X X X X X X
Negative sequence over current 460C X X X - X X X X X
Negative sequence thermal 46T - - - - X X X X X
Thermal overload 38/49 X X X X X X X X X
Under/Over voltage 27/59 X X X X X x X X X
Residual over voltage 59N X X X X X X X X X
Negative sequence over voltage 47 X X X X X X X X X
Under frequency 81U X X X X X X X X X
Over frequency 81D - - - X X X X X X
Turbine abnormal frequency 81AB - - - - X X X X X
Voltage vector shift Dv - - - X - - - - -
Rate of change of frequency 81R - - - X X X X X X
Circuit breaker fall and monitoring 50BF X X X X X X X X X
Loss of life/ Thru fault monitor LOL/Thru - - - X X X X X X
Dynamic line rating 49DLF - - - X - - - - -
Trip circuit supervision TCS X X X X X X X X X

26 * Prices Available on Request


MiCOM ALSTOM Protection
Distance protection relays

Device P441 P442 P443 P444

CT inputs 4 4 4 4
VT inputs 4 4 4 4
Opto inputs (max)1 8 16 32 24
Output contacts (max)1 14 21 32 46
Function keys/Hotkeys X X X X
Protection
Distance Protection 21/21N X X X X
Phase Mho/Quad 21P -/X -/X X/X -/X
Ground Mho/Quad 21G -/X -/X X/X -/X
3 pole X - - -
Auto reclose 79
1/3 pole - X X X
Out-of step tripping 78 X X X X
Out-of step tripping 68 - - X X
Check synchronizing 25 X X X X
Switch on to fault 50/27 X X X X
Mutual compensation X X X X
Phaser Measurement PMU - - - -
Ancillary function X X X X
Phase overcurrent 50/51 X X X X
Phase directional 67P X X X X
Delta directional comparsion 1V - - X -
Ground fault 50/51N X X X X
Ground fault directional 67N X X X X
Negatrive sequence overcurrent 46 X X X X
Directional negative sequence 46/67 X X X X
Thermal overlload 49 X X X X
Under/Over voltage 27/59 X X X X
Residual over voltage 59N X X X X
Under/over frequency 81U/O - X X X
Rate of change of frequency 81R - - X -
Circuit breaker failure 50BF X X X X
Broken conductor 46BC X X X X
Stub Bus protection 50ST X X X X
Voltage/Current Transformer Supervision VTS/CTS X X X X
Capactive voltage Transformer Supervision CVTS X X - X
Channel Aided Scheme Logic 85 X X X X
Trip Circuit Supervision TCS X X X X
Inter Micom - X X X
* Prices Available on Request

27
MiCOM ALSTOM Protection
Line Differential Transformer
& BusBar Protection Relays

Device P541 P542 P543 P544 P545 P546 P547 P642 P643 P645 P741 P742 P743 P746

CT inputs 4 4 5 8 5 8 4 8 12 18 4 4 4 18

VT inputs (Max) - - 4 5 4 5 4 1 4 4 - - - 3

Opto inputs (max)1 8 16 16 16 32 24 8 12 24 24 8 16 24 40


Output contacts (max)1 7 14 14 14 32 32 8 12 24 24 8 8 22 32

Analogue (optional)1 - - - - - - - 4/4 4/4 4/4 - - - -

RTDs (optional)1 - - - - - - - 10 10 10 - - - -

Function keys/Hotkeys X X X X X X X X X X X X X X
Interlocking logic X X X X X X X X X X X X X X

Protection

Line differential
87P X X X X X X - - - - - - - -
- 2 terminal

Neutral differential -
87N - X X X X - - - - - - - -

2/3 terminal X X X X X X - - - - - - - -

FO signalingr X X X X X X - - - - - - - -

SDH / SONET networks - - X - X X - - - - - - - -

In/zone transformer X X X - X - - - - - - - - -

2nd harmonic restraint X X X - X - - - - - - - - -

Vector compensation X X X - X - - - - - - - - -

2 breaker configuration - - - X - X - - - - - - - -

Direct/permissive inter tripping X X X X X X - - - - - - - -

Phase comparison -
87PC - - - - - X - - - - - - -

PLC signalling - - - - - - X - - - - - - -

Transformer Differential -
87T - - - - - - X X X - - - -

Winding/Bias inputs - - - - - - - 2 3 5 - - - -

Restricted Earth fault 87G84 - - - - - - - 2 3 5 - - - -

Over fluxing/5th harmonic - - - - - - - X X X - - - -

Over excitation 24 - - - - - - - X 2 2 - - - -

2nd harmonic restraint - - - - - - - X X X - - - -

Busbar protection 87BB - - - - - - - - - - X X X X

Central unit feeders - - - - - - - - - - 28 - - 6/18

Peripheral Units - - - - - - - - - - - X X -

Phase segregated - - - - - - - - - - - -
87P 8 2
differential zones
Sensitive Earth fault - - - - - - - - - - - - -
87N 6
differential zones
Check zone 87CZ - - - - - - - - - - 8 - - X

CT supervision CTS - - - - - - - - - - X X X X

CT saturation immunisation - - - - - - - - - - - X X X

Fibre optic signalling - - - - - - - - - - X X X -

28
* Prices Available on Request
MiCOM ALSTOM Protection
Line Differential Transformer
& BusBar Protection Relays

Device P541 P542 P543 P544 P545 P546 P547 P642 P643 P645 P741 P742 P743 P746

-Phase Overcurrent 50/51P X X X X X X X X X X - X X X

Phase Directional -
67P - - X X X X X X X X - - - -

Ground Fault 50/51N X X X X X X X X X X - X X X

Ground fault Directional 67N - - X X X X X X X X - - - -

CT supervision/Differential CTS CTS - - X X X X X X X X X X X X

Sensitive Directional Earth Fault 67N - - X X X X X - - - - - - -

Wattmetric Earth fault 64W - - X X X X X - - - - - - -

Distance protection 21 - - X X X X X - - - - - - -

Power swing blocking 78 - - X X X X X - - - - - - -


25
Check Sync - - X - X - X - - - - - - -

Negative Sequence Overcurrent -


46 X- - X X X X X X X X - - - -

Thermal overload 49 X X X X X X X X X - - - -

Loss of life and through fault LOL - - - - - - - X X X - - - -

Under/Over frequency 81U/O - - X X X X X X X X - - - -

Circuit breaker failure 50BF X X X 2 X 2 X 2 3 5 X X X 6/18

Auto reclose 79 - 3 Pole 1/3 - 1/3 - - - - - - - - -


Pole Pole
Over/Under voltage 27/59 - - X X X X - - X X - - - -

Trip circuit supervision TCS X X X X X X X X X X X X X X

* Prices Available on Request

29
Pallavaram Works West
ALSTOM T&D India Ltd.
ALSTOM T&D India Ltd.
Narottam Morarjee Marg, Ballard Estate,
19/1, G.S.T. Road, Pallavaram,
Mumbai - 400 038
Chennai - 600 043
Tel: 91-22-3021 0500
Tel: 91-44-2264 8000
Fax: 91-22-3021 0480
Fax: 91-44-2264 0040
South
North
ALSTOM T&D India Ltd.
ALSTOM T&D India Ltd.
IOC Building
A - 7, Sector - 65
19/1, G.S.T. Road, Pallavaram,
Noida - 201301, UP
Chennai - 600 043
Tel: 91-120-479 9000
Tel: 91-44-22648 9000
Fax: 91-120-4700288
Fax: 91-44-22648 4084

East
ALSTOM T&D India Ltd. For more information e-mail: salessupport@alstom.com
Alstom T&D Worldwide Contact Centre
DLF IT Park, Premises No. 08, In addition to these, Alstom T&D has 16 offices throughout India.
Major Arterial Road, Block Http://www.alstom.com/contactcentre/
AF Tower C, 8th Floor,New Town Tel: +44 (0) 17 85 25 00 70
Rajarhat, Kolkata - 700 156
Tel: 91-33-40097050 www.alstom.com
Fax: 91-33-40097043

GRID