This document provides calculations for confinement reinforcement of a rectangular concrete pier with a width and length of 2000 mm. It specifies the grade of concrete and steel, clear cover, core dimensions, tie spacing and diameter, and calculates the required and provided cross-sectional area of transverse reinforcement based on the pier's geometry and material properties. The provided area exceeds the requirement.
Original Description:
confining calculation of column rectangular as per is 13920
This document provides calculations for confinement reinforcement of a rectangular concrete pier with a width and length of 2000 mm. It specifies the grade of concrete and steel, clear cover, core dimensions, tie spacing and diameter, and calculates the required and provided cross-sectional area of transverse reinforcement based on the pier's geometry and material properties. The provided area exceeds the requirement.
This document provides calculations for confinement reinforcement of a rectangular concrete pier with a width and length of 2000 mm. It specifies the grade of concrete and steel, clear cover, core dimensions, tie spacing and diameter, and calculates the required and provided cross-sectional area of transverse reinforcement based on the pier's geometry and material properties. The provided area exceeds the requirement.
GRADE OF STEEL Fe(fy) 415 CLEAR COVER 50 mm WIDTH OF PIER 2000 mm LENGTH OF PIER 2000 mm ASSUMED TIES DIA 12 mm TIES SPACING (S) 150 mm CORE WIDTH OF PIER 1900 mm CORE LENGTH OF PIER 1900 mm LONGER DIMENSION OF CONFINING HOOP (H) 280 mm GROSS CROSS-SECTIONAL AREA (Ag) 4000000 sqmm CROSS SECTIONAL AREA OF CORE (Ak) 3610000 sqmm Ash (0.18SH(fck/fy)((Ag/Ak)-1) 98.40 sqmm < Ash Provided 113.10 sqmm OK