dEPTH OF BEAM EVALUATED USING DEFLECTION CRITERIA

WIDTH = DEPTH/2

FOR COLUMNS, SIZE OF COLUMN APPROXIMATELY RANGES BETWEEN H/10 TO H/20


COLUMNS CAN BE ANY SIZE AS LONG AS ARCHITECTURAL CONSTRAINTS DO NOT RESTRICT ITS
DIMENSIONS.

X-DIRECTION ( DEPTH X WIDTH)


27X14
30X15
33X17
36X18
Y-DIRECTION (DEPTH X WIDTH)
21X11
24X12
27X14
30X15
33X17
36X18
BEAM DEPTHS: MULTIPLE OF 3'SINCE COLUMN HEIGHT MUST MATCH THE HEIGHT OF THE WALL
THAT WILL BE SUPPORTED BY THE BEAM.
BEAM WIDTH IS APPROXIMATELY EQUAL TO BEAM HEIGHT/2
BEAM HEIGHT PREFERABLY MUST NOT GO BEYOND 3'IN DEPTH DUE TO ARCHITECTURAL CONSTR
AINTS
BEAM WIDTHS CAN BE DICTACTED BY WIDTH OF BRICKS (9") or column widths.

Modifiers:
Columns moi 3-3 & moi 2-20.35
Floor slabs bending modifiers (all) 0.25
Ramp slab bending modifiers (all) 0.25
Shear wall bending modifers (all)0.25