Professional Documents
Culture Documents
1 PB PDF
1 PB PDF
Abstract This paper presents the deployment of a new total From the viewpoint of power systems design and protection,
lightning detection network in Colombia. Historic data from 2011 the variation in time and space of lightning parameters that
to 2012 are used to reevaluate the lightning parameters such as measure the incidence (e.g. ground flash density, multiplicity)
ground flash density, multiplicity, polarity and others. Lightning
and intensity (e.g. return stroke peak current, polarity) makes
detections from LINET are used to develop real time warnings
and the opportune detection of failure risks for power lines. that international standards cannot be directly applied in
tropical countries such as Colombia. Some standards as
Index TermsThunderstorm nowcasting, severe weather IEEE1410 [13] have added some modifications for giving
recognition, total lightning detection, failure risk. special considerations for tropical zone, however more historic
data are required.
I. INTRODUCTION
On the basis of the Smart Grids concept, the real time
A S has been reported by several studies [1-7], the lightning
phenomenon has its maximum recurrence in tropical
regions and its physical parameters present variations
information about one of the most recurrent causes of power
quality disturbances, the lightning, allows developing smart
compared with those typically observed in other regions of the strategies for significantly reducing the unavailability of
word. One of the most lightning active zones worldwide is the power distribution systems. Some examples about the
region that connects the Magdalena River Valley in Colombia opportune prediction of the failure risk caused by lightning for
with the Catatumbo in Venezuela [8], besides the geographical real power distribution systems in Colombia are shown.
location, the big mountains in this region originates very
lightning dense locations, which are within the highest Ground
Flash Densities reported. Some figures show that between 60 II. VLF/LF LIGHTNING DETECTION SYSTEM LINET
and 70% of the failures in the Colombian Power Transmission Betz et al [11] presented in 2004 a new VLF/LF (very low
System are caused by lightning and more than 10000 power frequency/low frequency) lightning detection technique named
distribution transformers are destroyed every year; in addition, LINET. The location procedure is based on the known Time
it is believed that lightning is one of the most important causes Of Arrival (TOA) method, however the improved algorithm is
of power quality disturbances, in particular Sags [9]. This able to provide not only information of the horizontal
paper presents the implementation of the first Total Lightning (latitude, longitude) position of the observed lightning events
Detection Network in Colombia based on LINET systems [10] but also of its vertical position. As described by [12], LINET
and its application on the power quality improvement, mainly is sensible to VLF/LF signals from several processes involved
for power distribution lines. on intracloud - IC and cloud to ground - CG events, which
present strong currents flowing in relative long channels. For
CG strokes (or VLF/LF events) the emissions are supposed to
D. Aranguren is scientific director of Keraunos S.A.S. He is also with the be arisen from the ground strike point. For IC strokes, the
Research Group PAAS, National University of Colombia, Bogot, Colombia
(e-mail: daranguren@keraunos.co). VLF/LF channel source points are not precisely defined,
J. Inampues is with Keraunos S.A.S. He is also part of the Research Group however it is expected those are due to vertical channel
PAAS, National University of Colombia, Bogot, Colombia (e-mail: components. IC and CG strokes can be discriminated when the
juan.inampues@keraunos.co). used baselines between sensors are shorter than about 250 km.
J. Lopez is with Keraunos S.A.S. He is also part of the Research Group
PAAS, National University of Colombia, Bogot, Colombia (e-mail: Depending on the number of sensors, the baselines and the
jalopezt@keraunos.co). internal detection thresholds; it is possible to detect very weak
A. Tibaduiza is with Keraunos S.A.S, Bogot, Colombia (e-mail: strokes down to about 2 kA; due to the limited number of
manueltibaduiza@keraunos.co). sensors available up to date this goal is reached only in parts
F. Casas is with Seguridad Electrica S.A.S, Bogot, Colombia (e-mail:
gerencia@seguridadelectricaltda.com). of the network.
H. Torres is with the Electrical Engineering Department, National
University of Colombia, Bogot, Colombia (e-mail: htorress@unal.edu.co).
H. Betz is chief representative of nowcast GmbH, Munich, Germany (e-
mail: Hans-Dieter.Betz@nowcast.de).
Noviembre 2 7, 28 y 29
Medelln Colombia
2013
2
Noviembre 2 7, 28 y 29
Medelln Colombia
2013
3
Figure 4. Colombian Ground Falsh Density GFD (Cloud-to-ground flashes/km2/year) measured in Colombia and West Venezuela during 2012
Noviembre 2 7, 28 y 29
Medelln Colombia
2013
4
Noviembre 2 7, 28 y 29
Medelln Colombia
2013
5
Noviembre 2 7, 28 y 29
Medelln Colombia
2013
6
Noviembre 2 7, 28 y 29
Medelln Colombia