Outcome: The simulation error was corrected successfully. Changes Made: -Shunt resistance from analog nodes to ground (RSHUNT) was changed to 10 0000000
Multisim Convergence Assistant Log
Step 1: Verifying Error Scenario ...completed. Step 2: Setting parameter Integration Method (METHOD) to Gear Simulating... ...completed. Simulation error still occurs. Step 3: Setting parameter Initial Conditions to Set To Zero Simulating... ...completed. Simulation error still occurs. Step 4: Setting parameter Maximum Timestep (TMAX) to 1.0000e-004 Simulating... ...completed. Simulation error still occurs. Step 5: Setting parameter Maximum Timestep (TMAX) to 1.0000e-003 Simulating... ...completed. Simulation error still occurs. Step 6: Setting parameter Relative error tolerance (RELTOL) to 1.0000e-002 Simulating... ...completed. Simulation error still occurs. Step 7: Setting parameter Shunt resistance from analog nodes to ground (RSHUNT) to 1000000000 Simulating... ...completed. Simulation error still occurs. Step 8: Setting parameter Shunt resistance from analog nodes to ground (RSHUNT) to 100000000 Simulating... ...completed. Simulation error fixed. Step 9: Attempting rollback of Initial Conditions to Automatically Determine Simulating... ...Rollback successful. Step 10: Attempting rollback of Maximum Timestep (TMAX) to 1.0000e-005 Simulating... ...Rollback successful. Step 11: Attempting rollback of Relative error tolerance (RELTOL) to 1.0000e-003 Simulating... ...Rollback successful. Step 12: Attempting rollback of Shunt resistance from analog nodes to ground (RS HUNT) to 1.0000e+012 Simulating... ...Error recurred - rollback unsuccessful. Step 13: Restoring value of Shunt resistance from analog nodes to ground (RSHUNT ) to 100000000 Step 14: Attempting rollback of Integration Method (METHOD) to Trapezoidal Simulating... ...Rollback successful. Convergence Assistant completed successfully.