the next step in Automation

AADvance is the next step in automation


advancement, offering customers an even
greater level of choice, flexibility and
scaleability from their safety and critical
control system.
The AADvance solution is a truly Safety First, Safety Last
distributed, scaleable architecture
Hazards and risks are an inevitable
which comprises of both a
feature of any industrial plant.
hardware controller and a software
The protection of personnel, the
environment that allows the user
process itself and the environment
to specify the level of reliability and
surrounding it, remains a significant
availability they need throughout
part of the automation strategy.
their plant. AADvance offers a
Safety systems to date have
high level of flexibility from small
suffered in varying degrees from
quantity I/O to large systems;
compromise, usually either
non-safety to SIL 3, and fail-safe
performance, or their inability to be
to multiple fault tolerant.
applied on a variety of control needs
in a variety of architectures.
The single greatest threat to safety
remains human error and the
AADvance environment reduces that
risk. Users can control and update
their plant-wide safety management
system from a single AADvance
workstation, running several projects
from that station while the
controllers distributed throughout
the plant communicate intuitively,
vastly reducing time spent updating
individual terminals and the margin
for human error.
The AADvance Environment
The AADvance environment has AADvance benefits from the vast Simple but complete integration
been developed to compliment and experience ICS Triplex has gained between all AADvance enabled
integrate seamlessly with Trusted, from over 40 years in providing high controllers including existing ICS
the market-leading TMR controller, performance safety and critical Triplex proprietary systems as
and other existing ICS Triplex control technology in the widest well as third party AADvance
proprietary systems which are range of applications and the enabled equipment.
AADvance enabled. AADvance can continued desire to offer the best-
also integrate with third party in-class solutions on the market.
AADvance enabled equipment The AADvance concept is built on
which includes DCS, HMI, condition a set of fundamental requirements:
monitoring, metering, etc.
Cost effective for SIL1-3 in the
The AADvance products can be same system
distributed to fit a wide variety of
Appropriate for small to large
safety solution designs. Scaleability
I/O systems
in every sense is the unique quality
of AADvance technology. Choosing Scaleable redundancy for fault
AADvance with any control system tolerance
will increase diversity of all safety Distributed processing power
system components and limit the High performance regardless
compromises associated with trying of size
to make control system designs fit
Simple single point configuration
safety system applications.
and system management
The AADvance Network eliminating the need to have
separate synchronisation schemes
The AADvance environment
integrates all AADvance enabled easing the development and
controllers to work as a single maintenance of robust control
solution. The redundant network is systems.
an intrinsic part of any solution
The AADvance Control Station
where all of the resources can
perform their desired functions Any AADvance controller is modular
seamlessly. Only AADvance certified and easy to assemble, providing a
controllers can freely interact on this completely flexible and scaleable
network; however uncertified devices solution.
are allowed to share the network Performance and flexibility
infrastructure if desired. differentiates the AADvance
environment from other solutions.
The AADvance Workstation
Rather than one size fits all,
The AADvance workstation uses customers can now choose the
software that enables the user to redundancy appropriate for them in
design the complete control strategy all parts of the system, from fail safe
as one, then to target parts of the through to fault tolerant. Controllers
strategy at each controller. are specifically selected to meet
Interaction between the resources the distribution needs and to
is automatic, significantly reducing accommodate the I/O required in
the complexity of configuration in any individual part of the network.
a multi-resource solution. The unique ability for many controllers
The AADvance workstation software to appear as a single system, without
is the world's first automation complicating the management of the
software to be compliant with both configuration, also increases
IEC 61131 and IEC 61499 industrial simplicity and ease of use.
standards. This leading-edge
programming environment is
comprised of a powerful set of new
features including:
the regulation of the flow of control
decisions for an interacting
distributed control system
providing for the consistency of data
providing a means for
synchronous operation between
devices
AADvance Workstation

Single configuration - multiple control resources

I/P CPU O/P I/P CPU O/P I/P CPU O/P I/P CPU O/P

V V V V V V V V
O O O O O O O O
T T T T T T T T
E E E E E E E E

V V V V V V V V
O O O O O O O O
T T T T T T T T
E E E E E E E E

V V V V V V V V
O O O O O O O O
T T T T T T T T
Fault Tolerant Bus
E E E E E E E E

Fault Containment Regions Fault Containment Regions Fault Containment Regions Fault Containment Regions

SIL1-2 SIL1-3 SIL1-3 AADvance Enabled TrustedTM AADvance Enabled TMC 6210
Fail Safe Fault Tolerant Fault Tolerant SIL1-3 Incipient Surge Detection
Distributed Architecture Distributed Architecture Distributed Architecture Fault Tolerant TMR Scaleable TMC Solutions
2-1-0 Degradation 3-2-1-0 Degradation Centralised Architecture Simplex to TMR
High Density Advanced Surge Control
3-3-2-0 Degradation Capacity Control & Load-sharing

AADvance Controller Scaleability: SIL1-3, Small to large I/O Systems SIL 3 TMR TMC

Unique Features and Benefits Scaleable from small quantity I/O AADvance Certification
of AADvance to large systems
IEC 61508 TUV SIL 1 to 3 rated
1, 2, or 3 CPU modules with Single Programming Environment
IEC 298
auto voting Hazardous Area Mounting
IEC 50156
Up to 48 I/O modules per (Class 1 Div II or Zone 2)
NFPA 72, NFPA 85 & NFPA 86
controller Channel isolation
EN61131-2
Any mix of 1, 2 or 3 input Built in version control
module configurations EN61000-6-2, EN61000-6-4
Online replacement
Any mix of 1 or 2 output module EN54-2
Online changes
configurations AADvance enabled 3rd Party
Web based diagnostics
HART integration and intelligent products
(user controlled)
field monitoring
IEC 61131/61499 programming
Flexible modular construction environment
Scaleable fault tolerance Fuseless outputs
Flexible safety integrity: Remote and Local I/O without
IEC 61508 SIL 1 to 3 special modules
TUV certified operating system Black channel communications
Truly distributed architecture Scaleable performance
Fail-safe to fault tolerant
configurations
ICS Triplex products are in service onshore and offshore, throughout the globe

Americas Europe, Middle East & Africa Asia Pacific


Telephone +1 713 353 2400 +44 1621 854444 +65 6863 3319
Telefax +1 713 353 2401 +44 1621 851531 +65 6863 3369
Email sales@icstriplex.com sales@icstriplex.com sales@icstriplex.com

4325 West Sam Houston Hall Road 2 Tuas South Street 2#02-01/02
Parkway North Maldon Sprintecs Industrial Building
Suite 100 Essex CM9 4LA Singapore 637895
Houston UK
Texas 77043
USA

ICS Triplex Offices Worldwide:


Aberdeen, UK
Abu Dhabi, UAE
Al Khobar, KSA
Anzures, Mexico
Beijing, China
Houston, USA
Maldon, UK
Milan, Italy
Montreal, Canada
Paris, France
Perth, Australia

www.icstriplex.com

You might also like