You are on page 1of 1

VERTICAL ANALYSIS Figure 1

Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static

Vertical Load, Q= 800.0 -kN


Shear Load, P= 0.0 -kN
Moment, M= 0.0 -kN-m

Profile:
Pile Length, L= 24.0 -m
Top Height, H= 0.1 -m
Slope Angle, As= 0
Batter Angle, Ab= 0

Free Head Condition

Driving Concrete Pile

Soil Data: Pile Data:


Depth Gamma Phi C K e50 or Dr Nspt Depth Width Area Per. I E Weight
-m -kN/m3 -kN/m2 -MN/m3 % -m -cm -cm2 -cm -cm4 -MP -kN/m
0.000 5.4 25.7 0.0 0.3 2.71 1 0.0 40 779.1 125.7 107517.9 20683 1.837
10 7.9 32.1 0.0 7.1 30.24 8 24.0 40 779.1 125.7 107517.9 20683 1.837
20 9.8 38.8 0.0 32.1 73.88 39
24 11.2 40.8 0.0 47.9 90.85 55

Vertical capacity:
Weight above Ground= 0.18 Total Weight= 14.66-kN *Soil Weight is not included
Side Resistance (Down)= 571.899-kN Side Resistance (Up)= 351.942-kN
Tip Resistance (Down)= 938.368-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 1510.267-kN Total Ultimate Capacity (Up)= 366.597-kN
Total Allowable Capacity (Down)= 719.175-kN Total Allowable Capacity (Up)= 261.855-kN
N/G! Qallow < Q

Settlement Calculation:
At Q= 800.00-kN Settlement= 1.14800-cm
At Xallow= 2.50-cm Qallow= 1232.04590-kN

Note: If program can't find result or the result exceeds the up limits. The result shows 9999.

CivilTech PERENCANAAN PENGEMBANGAN PABRIK GULA


Software SPUN 400mm PONDASI BOILER