Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static
Profile:
Pile Length, L= 24.0 -m
Top Height, H= 0.1 -m
Slope Angle, As= 0
Batter Angle, Ab= 0
Vertical capacity:
Weight above Ground= 0.18 Total Weight= 14.66-kN *Soil Weight is not included
Side Resistance (Down)= 571.899-kN Side Resistance (Up)= 351.942-kN
Tip Resistance (Down)= 938.368-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 1510.267-kN Total Ultimate Capacity (Up)= 366.597-kN
Total Allowable Capacity (Down)= 719.175-kN Total Allowable Capacity (Up)= 261.855-kN
N/G! Qallow < Q
Settlement Calculation:
At Q= 800.00-kN Settlement= 1.14800-cm
At Xallow= 2.50-cm Qallow= 1232.04590-kN
Note: If program can't find result or the result exceeds the up limits. The result shows 9999.