Repeat Cycle: After a predetermined time, the output U T T T T TDRPRO-5100,
Starting Open periodically switches on and off with substantially TDRPRO-5101,
(B) identical pulse on time and pulse off time. ON OFF ON OFF TDRPRO-5102,
R
time TDRSOX
Repeat Cycle: The output immediately begins to switch off and U T T T T 821, 822,
Starting Closed on periodically with substantially identical pulse TDRPRO-5100,
(F) off time and pulse on time. ON OFF ON OFF TDRPRO-5101
R
time
The time delay starts when applying the power U T 821, 822,
Pulse Generator supply; the output momentarily switches for an
TDRPRO-5100,
(G) interval to the operate condition after the time
TDRPRO-5101
delay has elapsed. R
time
U
Upon application of the coil voltage, the relay waits
821, 822,
Memory Latch for trigger signaling. The contacts transfer each S TDRPRO-5100,
(J) time the trigger closes. There is no timing function
TDRPRO-5101
involved (i.e. flip-flop function).
R
time
T = Setting time